Wen-Chau Wu

Wen-Chau Wu

Auto-generated profile, based on publicly available information

Wen-Chau Wu

Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2007 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
WWWen‐Chau Wu
Wen‐Chau Wu
MFMaría. A. Fernández-Seara
María. A. Fernández-Seara
JDJohn A. Detre
John A. Detre
FWFelix W. Wehrli
Felix W. Wehrli
JWJiongjiong Wang
Jiongjiong Wang
Arterial spin labeling (ASL) is capable of noninvasively measuring blood flow by magnetically tagging the protons in arterial blood, which has been conventionally achieved using instantaneous (PASL) or continuous (CASL) RF pulses. As an intermediate method, pseudocontinuous ASL (pCASL) utilizes a train of discrete RF pulses to mimic continuous tagging that is often unavailable on imagers due to the requirement of continuous RF transmit capabilities. In the present study, we implemented two versions of pCASL (balanced and unbalanced gradient waveforms in tag and control scans) for both transmit/receive coils and array receivers. Experimental data show a 50% ± 4% increase of signal‐to‐noise ratio (SNR) compared with PASL and a higher tagging efficiency than amplitude‐modulated (AM) CASL (80% vs. 68%). Computer simulations predict an optimal tagging efficiency of 85% for flow velocities from 10 to 60 cm/s. It is theoretically and experimentally demonstrated that the tagging efficiency of pCASL is dependent upon the resonance offset and flip angle of the RF pulse train. We conclude that pCASL has the potential of combining the merits of PASL, including less hardware demand and higher tagging efficiency, and CASL, which includes a longer tagging bolus and thus higher SNR. These improvements provide a better balance between tagging efficiency and SNR. Magn Reson Med 58:1020–1027, 2007.

1 February 2010 in NeuroImage
Verified
Journal Article
Closed access
JLJulian Lim
Julian Lim
WWWen-Chau Wu
Wen-Chau Wu
JWJiongjiong Wang
Jiongjiong Wang
JDJohn A. Detre
John A. Detre
DDDavid F. Dinges
David F. Dinges
HRHengyi Rao
Hengyi Rao

12 May 2006 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
EWEric C. Wong
Eric C. Wong
MCMatthew Cronin
Matthew Cronin
WWWen‐Chau Wu
Wen‐Chau Wu
BIBen Inglis
Ben Inglis
LFLawrence R. Frank
Lawrence R. Frank
TLThomas T. Liu
Thomas T. Liu

1 October 2011 in Psychiatry Research: Neuroimaging
Verified
Journal Article
Closed access
APAmy Pinkham
Amy Pinkham
JLJames Loughead
James Loughead
KRKosha Ruparel
Kosha Ruparel
WWWen-Chau Wu
Wen-Chau Wu
EOEve Overton
Eve Overton
RGRuben Gur
Ruben Gur

19 February 2015 in European Radiology
Verified
Journal Article
Open access
PDF file
WWWen-Chau Wu
Wen-Chau Wu
YCYa-Fang Chen
Ya-Fang Chen
HTHan-Min Tseng
Han-Min Tseng
SYShun-Chung Yang
Shun-Chung Yang
PMPei-Chi My
Pei-Chi My
Objectives To numerically and experimentally investigate the robustness of intravoxel incoherent motion (IVIM) magnetic resonance imaging in measuring perfusion indexes in the human brain. Methods Eighteen healthy volunteers were imaged on a 3 T clinical system. Data of IVIM imaging (12 b-values ranging from 0 to 1000 s/mm2, 12 repetitions) were fitted with a bi-exponential model to extract blood volume fraction (f) and pseudo-diffusion coefficient (D*). The robustness of measurement was assessed by bootstrapping. Dynamic susceptibility contrast (DSC) imaging and arterial spin-labelling (ASL) imaging were performed for cross-modal comparison. Numerical simulations were performed to assess the accuracy and precision of f and D* estimates at varied signal-to-noise ratio (SNRb1000). Results Based on our experimental setting (SNRb1000 ~ 30), the average error/variability is ~5 %/25 % for f and ~100 %/30 % for D* in gray matter, and ~10 %/50 % for f and ~300 %/60 % for D* in white matter. Correlation was found between f and DSC-derived cerebral blood volume in gray matter (r = 0.29 – 0.48 across subjects, p < 10-5), but not in white matter. No correlation was found between f-D* product and ASL-derived cerebral blood flow. Conclusions f may provide noninvasive measurement of cerebral blood volume, particularly in gray matter. D* has limited robustness and should be interpreted with caution. Key Points • A minimum SNR b1000 of 30 is recommended for reliable IVIM imaging. • f may provide noninvasive measurement of cerebral blood volume. • f correlates with CBV DSC in gray matter. • There is no correlation between fD* and CBF ASL . • D* has limited robustness and should be interpreted with caution.

17 June 2010 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
WWWen‐Chau Wu
Wen‐Chau Wu
VJVarsha Jain
Varsha Jain
CLCheng Li
Cheng Li
MGMariel Giannetta
Mariel Giannetta
HHHallam Hurt
Hallam Hurt
DWDanny J. J. Wang
Danny J. J. Wang
A time‐efficient method is described for in vivo venous blood T1 measurement using multiphase inversion‐recovery‐prepared balanced steady‐state free precession imaging. Computer simulations and validation experiments using a flow phantom were carried out to demonstrate the accuracy of the proposed method for measuring blood T1 by taking advantage of the continuous inflow of fresh blood with longitudinal magnetization undisturbed by previous radiofrequency pulses. In vivo measurement of venous blood T1 in the sagittal sinus was carried out in 26 healthy children and adults aged 7–39 years. The measured venous blood T1 values decreased with age as a whole (P = 0.006) and were higher in females than males (P = 0.013), matching the expected developmental changes and gender differences in human hematocrit level. The estimated mean blood T1 values were highly correlated with normal hematocrit levels across age and gender groups (Spearman's r = 0.93, P = 0.008). The longitudinal repeatability of this technique was 4.0% as measured by the within‐subject coefficient of variation. The proposed multiphase inversion recovery‐prepared balanced steady‐state free precession imaging method is a feasible technique for fast (<1 min) and reliable in vivo venous blood T1 measurement and may serve as an index of hematocrit level in individual subjects. Magn Reson Med, 2010.