Representative Publications

View All Publications
28 June 2018 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
MPMiriam Pyka
Miriam Pyka
PEPatrik Eschle
Patrik Eschle
CSChristian Sommer
Christian Sommer
MWMathias S. Weyland
Mathias S. Weyland
RKRahel Kubik
Rahel Kubik
SSStephan Scheidegger
Stephan Scheidegger
During mammography, the thyroid is exposed to scattered radiation from breast tissue and the device. This may increase the risk of radiation induced thyroid cancer. We investigated the scatter radiation exposition of the thyroid and the effect of a tailored thyroid protection in phantom and patient as well as by using Monte Carlo simulation (MCS). The protective effect of a modified thyroid protection, the relevance of the protective effect and acceptance by patients have been investigated. Phantom and patient measurements provided higher values for the surface dose at thyroid position than expected from MCS (phantom 0.32 mGy; patients 0.38 mGy; MCS 0.16 mGy). Phantom measurements indicated scatter contributions from both breast tissue and collimator/tube system. The value found in our patient study is within the range of the literature (0.22–0.39 mGy). The thyroid protection significantly reduced the surface dose but the dose (0.016 mGy) was higher than that expected from the lead equivalent value. However, the impact of the collar to the effective dose was small (< 4%). The collar was not visible on mammograms. Scatter from the collimator/tube system contributed with 50% to the thyroid dose. Due to the relative small fraction of dose deposited in the thyroid when compared to the mean glandular dose to the breast, a collar is not mandatory in general. Not being associated with the risk of obscuring parts of mammograms, such a collar may be used for young women considering their higher radio sensitivity.

24 May 2017 in The Journal of Arthroplasty
Verified
Journal Article
Open access
PDF file
FDFabio D'Isidoro
Fabio D'Isidoro
PEPatrik Eschle
Patrik Eschle
TZThomas Zumbrunn
Thomas Zumbrunn
CSChristian Sommer
Christian Sommer
SSStephan Scheidegger
Stephan Scheidegger
SFStephen John Ferguson
Stephen John Ferguson
Background Video fluoroscopy is a technique currently used to retrieve the in vivo three-dimensional kinematics of human joints during activities of daily living. Minimization of the radiation dose absorbed by the subject during the measurement is a priority and has not been thoroughly addressed so far. This issue is critical for the motion analysis of the hip joint, because of the proximity of the gonads. The aims of this study were to determine the x-ray voltage and the irradiation angle that minimize the effective dose and to achieve the best compromise between delivered dose and accuracy in motion retrieval. Methods Effective dose for a fluoroscopic study of the hip was estimated by means of Monte Carlo simulations and dosimetry measurements. Accuracy in pose retrieval for the different viewing angles was evaluated by registration of simulated radiographs of a hip prosthesis during a prescribed virtual motion. Results Absorbed dose can be minimized to about one-sixth of the maximum estimated values by irradiating at the optimal angle of 45° from the posterior side and by operating at 80 kV. At this angle, accuracy in retrieval of internal-external rotation is poorer compared with the other viewing angles. Conclusion The irradiation angle that minimizes the delivered dose does not necessarily correspond to the optimal angle for the accuracy in pose retrieval, for all rotations. For some applications, single-plane fluoroscopy may be a valid lower dose alternative to the dual-plane methods, despite their better accuracy.

7 September 2017 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
CSChristian Sommer
Christian Sommer
NINiels Icken
Niels Icken
IÖIsmail Özden
Ismail Özden
GLGerd Lutters
Gerd Lutters
SSStephan Scheidegger
Stephan Scheidegger
The use of optimised CT protocols regarding radiation exposure is a legal requirement. Since low contrast visibility is intrinsically varying within the CT slice, there is no adequate method for optimisation of dose and image quality. We developed a method to access image quality in a way that represents the situation closer to a real patient. This method is based on a novel difference detail curve (DDC) phantom with low contrast objects representing native tissue contrast and contrast media with different densities and diameters. The position of the contrast objects have been evaluated by a noise level analysis of CT slices of different manufactures. The dose – length – product can be measured within the phantom simultaneously. For all tested manu-factures and CT protocols, the noise analysis revealed a similar spatial variation of the signal -to-noise ratio (SNR). For the DDC method, contrast steps of 6 (4-8) Hounsfield Units (HU) are adequate. For the different CT units, comparable low contrast detectability is associated with remarkably varying dose levels (CTDI range from 8 to 18 mGy for native contrast and 9-16 mGy for contrast media). The novel DDC phantom is sensitive to protocol optimisations and therefore suitable for rating subtle effects caused by protocol optimisation.

17 February 2022 in Zeitschrift für Medizinische Physik
Verified
Journal Article
Open access
CSChristian Sommer
Christian Sommer
IÖIsmail Özden
Ismail Özden
MWMathias Weyland
Mathias Weyland
CDCarolina Duran
Carolina Duran
GLGerd Lutters
Gerd Lutters
SSStephan Scheidegger
Stephan Scheidegger
This work describes a measurement method for assessing dose-related image-quality of CT scans based on the difference detail curve (DDC) method, and showcases its use in a low contrast setting. The method is based on a phantom consisting of elliptical slices of different sizes into which contrast object modules can be inserted. These modules contain contrast objects based on (synthetic) resin mixtures with sucrose (native) or sodium iodine (contrast medium). Mixing ratios are provided to achieve a range of clinically relevant CT-numbers with these materials. The phantom is characterized in terms of contrast accuracy, energy dependency and long-term drift with satisfying results. Contrast accuracy and energy dependency are similar to that of water or soft tissue. Image quality of 655 scans of the phantom acquired at 30 different clinical institutions and with 16 different CT scanner models from 4 manufacturers was assessed by calculating a difference detail curve (DDC) from evaluation of up to 5 human observers using a custom-made software (RadiVates) described in this work. Based on these measurements, inter-observer variability was quantified using a bootstrap method and was shown to be a large contributor to the overall variability. This work demonstrates that assessment of CT image quality is feasible with the aforementioned phantom and DDC method.

21 May 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
DSDavid Stocker
David Stocker
CSChristian Sommer
Christian Sommer
SGSarah Gueng
Sarah Gueng
JSJason Stäuble
Jason Stäuble
IÖIsmail Özden
Ismail Özden
SSStephan Scheidegger
Stephan Scheidegger
Optimizing complex imaging procedures within Computed Tomography, considering both dose and image quality, presents significant challenges amidst rapid technological advancements and the adoption of machine learning (ML) methods. A crucial metric in this context is the Difference-Detailed Curve, which relies on human observer studies. However, these studies are labor-intensive and prone to both inter- and intra-observer variability. To tackle these issues, a ML-based model observer utilizing the U-Net architecture and a Bayesian methodology is proposed. In order to train a model observer unaffected by the spatial arrangement of low-contrast objects, the image preprocessing incorporates a Gaussian Process-based noise model. Additionally, gradient-weighted class activation mapping is utilized to gain insights into the model observer’s decision-making process. By training on data from a diverse group of observers, well-calibrated probabilistic predictions that quantify observer variability are achieved. Leveraging the principles of Beta regression, the Bayesian methodology is used to derive a model observer performance metric, effectively gauging the model observer’s strength in terms of an ‘effective number of observers’. Ultimately, this framework enables to predict the DDC distribution by applying thresholds to the inferred probabilities (Part of this work has been presented at: Stocker D, Sommer C, Gueng S, Stäuble J, Özden I, Griessinger J, Weyland M S, Lutters G, Scheidegger S (2023). Probabilistic U-Net Model Observer for the DDC Method in CT Scan Protocol Optimization. The 56th SSRMP Annual Meeting 2023, November 30. - December 1., 2023, Luzern, Switzerland).

18 June 2026 in Physics in Medicine & Biology
Verified
Journal Article
Open access
MKMehrnoosh Karimipourfard
Mehrnoosh Karimipourfard
DSDavid Stocker
David Stocker
CSChristian Sommer
Christian Sommer
MWMathias Weyland
Mathias Weyland
HMHojjat Mahani
Hojjat Mahani
SSStephan Scheidegger
Stephan Scheidegger
Robust radiomic features are critical for reliable quantitative CT analysis; however, their reproducibility is limited by variations in acquisition protocols. This study aims to (1) identify radiomic features predictive of low-contrast detectability, (2) quantify their sensitivity to acquisition parameters, and (3) integrate these factors through a feature-level trade-off framework for CT protocol optimization. A phantom containing 30 inserts was scanned across multiple CT protocols, and 107 radiomic features were extracted. Feature robustness was assessed using CV and ICC, followed by ComBat harmonization, which approximately doubled the proportion of reproducible features. A random forest model achieved strong performance (AUC = 0.94, accuracy = 0.90), with first-order features showing the highest predictive power. Sensitivity analysis using Spearman’s correlation revealed that texture features were more influenced by protocol variations ( ρ ≈ 0.15–0.17), while shape features were more associated with dose ( ρ ≈ 0.13–0.14). A consistent trade-off was observed between detectability and sensitivity (−0.07 to −0.17), indicating that maximizing detectability alone is insufficient for protocol design. The proposed framework enabled systematic protocol ranking, demonstrating that moderate acquisition settings provide a more balanced and robust performance. These findings establish a quantitative foundation for radiomics-informed CT protocol optimization, with potential for further validation in clinical settings.