Ahmed M. Elkotb

Ahmed M. Elkotb

Auto-generated profile, based on publicly available information

Ahmed M. Elkotb

Ain Shams Univ, Fac Med, Dept Obstetr & Gynecol, Cairo 11591, Egypt

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2017 in The Journal of Maternal-Fetal & Neonatal Medicine
Verified
Journal Article
Closed access
AAAhmed Alanwar
Ahmed Alanwar
HAHelmy M. Al-Sayed
Helmy M. Al-Sayed
AIAhmed M. Ibrahim
Ahmed M. Ibrahim
AEAhmed M. Elkotb
Ahmed M. Elkotb
AAAhmed Abdelshafy
Ahmed Abdelshafy
MNMaii Nawara
Maii Nawara
Background/objective: The purpose of this study is to evaluate the cases of lower urinary tract injuries during cesarean section with or without hysterectomy in cases with morbid placental adherence. Methods: This record based retrospective study was conducted at Ain Shams University Maternity Hospital in Cairo, Egypt during the period between January 2014 and December 2016. It included all patients who had urinary tract injuries during cesarean section with or without hysterectomy in the cases with morbid placental adherence and they were collected from files of pregnant women who were admitted at hospital planned for termination of pregnancy. Patients were enrolled in four groups, Group 1: cases without urinary tract injuries. Group 2: cases with injuries to the bladder. Group 3: cases with injuries of the ureter. Group 4: cases with injuries to the bladder and ureter. Results: This study gave us new information about the incidence of urinary tract injuries during cesarean section with morbid adherence placenta was 21.7% (Bladder 11.7%, Ureter 4.7%, and bladder with ureter 5.3%). There were various types of repair of urinary tract injury, as the following, bladder repair 10.8%, ureteric catheterization 0.9%, ureterovesical repair or reimplantation 1.5%, bladder repair and ureterovesical 1.2%, bladder repair and ureteric catheterization 2.3%, ureteric catheterization and ureterovesical 1.5 and 6.4% of cases needed urologic consultations. There is a real relation between urinary tract injury and obesity (55.3%). Bladder invasion was found in only 26.9% of all cases according to sonography findings. Most of the cases were delivered by cesarean section in 67.5%, and the remainders were delivered by cesarean hysterectomy 32.5%. About 96.5% of cases needed a blood transfusion. Conclusions: The morbid adherent placenta is still a challenge, which faces us as obstetricians, due to high morbidity and mortality. A multidisciplinary team is mandatory to avoid complications.

12 October 2017 in The Journal of Maternal-Fetal & Neonatal Medicine
Verified
Journal Article
Closed access
Mohamed LabanMohamed Laban
Mohamed Laban
GMGhada M. Mansour
Ghada M. Mansour
AEAhmed El-Kotb
Ahmed El-Kotb
AHAlaa Hassanin
Alaa Hassanin
ZLZina Laban
Zina Laban
ASAbdelrahman Saleh
Abdelrahman Saleh
Objective: The objective of this study is to estimate optimal cut-off values for mean fetal lung volume (FLV) and pulmonary artery resistance index (PA-RI) as non-invasive measures to predict neonatal respiratory distress syndrome (RDS) in preterm fetuses. Methods: A prospective study conducted at Ain Shams University Maternity Hospital, Egypt from May 2015 to July 2017: 80 eligible women diagnosed with preterm labor were recruited at 32–36 weeks’ gestation. Before delivery, three-dimensional ultrasound was used to estimate FLV using virtual organ computer-aided analysis (VOCAL), while PA-RI was measured by Doppler ultrasonography. Results: A total of 80 women were examined. Thirty-seven (46%) of the newborns developed neonatal RDS. FLV was significantly lower in neonates who developed RDS (p = .04), whereas PARI was significantly higher in those who did not (p = .02). Cut-off values of FLV ≤27.2 cm3 and PARI ≥0.77 predicted the subsequent development of RDS. Combining both cut-offs generated a more sensitive and specific methodical approach for the prediction of RDS (sensitivity 100%, specificity 88.5%). Conclusion: Measurement of FLV or PA-RI can predict RDS in preterm fetuses. Combined use of both measures bolstered their predictive significance.

27 July 2017 in The Journal of Maternal-Fetal & Neonatal Medicine
Verified
Journal Article
Closed access
Mohamed LabanMohamed Laban
Mohamed Laban
AAAhmed A. Alanwar
Ahmed A. Alanwar
MEMohamed K. Etman
Mohamed K. Etman
MEMohammed S. Elsokkary
Mohammed S. Elsokkary
AEAhmed M. Elkotb
Ahmed M. Elkotb
NNNancy M. Noah
Nancy M. Noah
Background/objective: This study aimed to evaluate accuracy of five-dimensional long bones (5D LB) compared to two-dimensional ultrasound (2DUS) biometry to predict fetal weight among normal term women. Methods: Fifty six normal term women were recruited at Ain Shams Maternity Hospital, Egypt from 14 May to 30 November 2015. Fetal weight was estimated by Hadlock’s IV formula using 2DUS and 5D LB. Estimated fetal weights (EFW) by 2DUS and 5D LB were compared with actual birth weights (ABW). Results: Mean femur length (FL) was 7.07 ± 0.73 cm and 6.74 ± 0.67 cm by 2DUS and 5D LB (p = .02). EFW was 3309.86 ± 463.06 g by 2DUS and 3205.46 ± 447.85 g by 5D LB (p = .25). No statistical difference was observed between ABW and EFW by 2DUS (p = .7) or 5D LB (p = .45). Positive correlation was found between EFW by 2DUS, 5D LB, and ABW (r = 0.67 and 0.7; p < .001). There was strong agreement between FL measured by 2DUS and 5D LB (ICC = 0.78), and perfect agreement between EFW by 2DUS and EFW by 5D LB (ICC = 0.918). 2DUS and 5D LB showed mean absolute percentage error for EFW of 10 ± 7% and 8 ± 7% compared to ABW (p = .15). Conclusions: 2DUS and 5D LB had same accuracy for fetal weight estimation at normal term pregnancy.

12 August 2021 in Journal of Pure and Applied Microbiology
Verified
Journal Article
Open access
NANoha G. Abdallah
Noha G. Abdallah
FAFaten M. Ali
Faten M. Ali
LALamiaa A. Adel
Lamiaa A. Adel
AEAhmed M. Elkotb
Ahmed M. Elkotb
WIWalaa A. Ibrahim
Walaa A. Ibrahim