Alaa Sayed Hassanin

Alaa Sayed Hassanin

Auto-generated profile, based on publicly available information

Alaa Sayed Hassanin

Department of Obstetrics and Gynecology, Ain Shams Maternity Hospital, Faculty of Medicine, Ain Shams University, Cairo, Egypt

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2014 in European Journal of Obstetrics & Gynecology and Reproductive Biology
Verified
Journal Article
Closed access
Mohamed LabanMohamed Laban
Mohamed Laban
EIEman Abdel-Salam Ibrahim
Eman Abdel-Salam Ibrahim
MEMohammed Saeed Eldin Elsafty
Mohammed Saeed Eldin Elsafty
AHAlaa Sayed Hassanin
Alaa Sayed Hassanin

1 January 2015 in Clinical Medicine Insights: Women's Health
Verified
Journal Article
Open access
SESherif F. Elmekkawi
Sherif F. Elmekkawi
GMGhada M. Mansour
Ghada M. Mansour
MEMohammed S.E. Elsafty
Mohammed S.E. Elsafty
AHAlaa S. Hassanin
Alaa S. Hassanin
Mohamed LabanMohamed Laban
Mohamed Laban
HEHeba M. Elsayed
Heba M. Elsayed
Objective: The aim of this study was to estimate the accuracy of prenatal assessment of interventricular septum (IVS) thickness, right myocardial wall thickness (RMWT), and left myocardial wall thickness (LMWT) by two-dimensional (2D) ultrasound for the prediction of perinatal mortality and postnatal diagnosis of hypertrophic cardiomyopathy (HCM) among diabetic pregnant women. Subjects and Methods: A total of 120 diabetic pregnant women at 35 weeks or more were enrolled in this study from January 1, 2012, to June 30, 2014, at Ain Shams Maternity Hospital, Cairo, Egypt. The 2D ultrasound was done once for all the participants at the time of recruitment; IVS thickness, RMWT, and LMWT were measured. The glycosylated hemoglobin (HbA1c) levels of the participants were recorded. Neonatal assessment including postnatal echocardiography was done after 48 hours. Postnatal results were compared with the prenatal predictive results. Results: Higher thickness values for IVS, RMW, and LMW were obtained in the uncontrolled diabetic cases (HbA1c > 6.5%) than in the controlled diabetic cases (HbA1c < 6.5%; P < 0.01). Of the included 120 neonates, 10 (8.3%) were stillborn, 99 (82.5%) had a five-minute Apgar score ≥7, and 4(3.3%) had a five-minute Apgar score ≤3. The four neonates with severe neonatal distress died after admission to neonatal intensive care unit within one week after delivery. Out of 110 live-born neonates, 4 (3.6%) neonates had a low ejection fraction (EF) (<50%) due to HCM; of them 2 (1.8%) died within one week after delivery, while 2 (1.8%) survived. Another two (1.8%) neonates died from severe respiratory distress syndrome. A cutoff value of ≥4.5 mm for prenatal IVS thickness was predictive of neonatal distress due to HCM with a sensitivity of 82%, specificity of 68%, and diagnostic accuracy of 72%. A cutoff value of <1.18 for the ratio of IVS thickness to LMWT had a sensitivity of 82%, specificity of 72%, and diagnostic accuracy of 74% for the prediction of neonatal distress due to HCM. In this study, 8 of the 10 fetuses with intrauterine demise and the 2 neonates who died within one week after delivery due to heart failure had a prenatal IVS thickness of ≥4.5 mm, while 7 of the 10 fetuses with intrauterine demise and the 2 neonates who died postnatal from heart failure had a prenatal IVS thickness to LMWT ratio of ≤1.18. Conclusion: A prenatal IVS thickness of ≥4.5 mm or an IVS/LMWT ratio of ≤1.18 seems to be predictive of HCM and is associated with almost twofold higher risk of intrauterine fetal death and almost threefold higher risk of possibly relevant perinatal mortality.

15 November 2014 in International Journal of Gynecology & Obstetrics
Verified
Journal Article
Closed access
Mohamed LabanMohamed Laban
Mohamed Laban
GMGhada M. Mansour
Ghada M. Mansour
MEMohammed S.E. Elsafty
Mohammed S.E. Elsafty
AHAlaa S. Hassanin
Alaa S. Hassanin
SESahar S. EzzElarab
Sahar S. EzzElarab

17 March 2022 in BMC Pregnancy and Childbirth
Verified
Journal Article
Open access
PDF file
AHAlaa S. Hassanin
Alaa S. Hassanin
HEHazem F. El-Shahawy
Hazem F. El-Shahawy
SHSherif Hanafi Hussain
Sherif Hanafi Hussain
AEAhmed M. Bahaa Eldin
Ahmed M. Bahaa Eldin
MEMarwa Mohammed Elhawary
Marwa Mohammed Elhawary
MEMohammed S. E. Elsafty
Mohammed S. E. Elsafty
To evaluate the impact of interval between induction of spinal anesthesia to delivery of the fetus by elective cesarean section on umbilical arterial pH and neonatal outcome. Two hundred and twenty pregnant women who were planned for elective cesarean section at term under spinal anesthesia were recruited. Minimum systolic, diastolic and mean arterial blood pressures (SBP, DBP, MAP) and largest pressure decrease (SBP, DBP, MPA) were also recorded. Induction of spinal anesthesia to delivery interval was measured. Following delivery, umbilical arterial cord analysis for pH and base deficit were done. Apgar scores at 1 min and at 5 min, neonatal intensive care unit (NICU) admission, need for mechanical ventilation and incidence of hypoxemic-ischemic encephalopathy were recorded. Induction of spinal anesthesia to delivery interval was 25.7 ± 5.6 min. Lowest SBP and MAP reached during cesarean delivery were 88.9 ± 7.3 mmHg and 60.4 ± 5.6 mmHg, respectively. MAP < 65 mmHg was reached in 136 (62%) patients with a decrease of MAP of > 20% in 149 (68%) patients. Duration of the longest hypotension episode was 3.3 ± 2.2 min. All patients required ephedrine administration for hypotensive episodes with an average dosage of 11.4 ± 3.2 mg. Umbilical pH of 7.3 ± 0.1 and base deficit of 8.3 ± 4.4 mmol/l were recorded. Apgar scores at 5 min were 8.5 ± 1.2. Eight (3.6%) neonates were admitted in the NICU. One neonate needed mechanical ventilation. There were no cases of hypoxemic-ischemic encephalopathy. There were inverse correlations between induction of spinal anesthesia to delivery interval, body mass index (BMI) and duration of longest hypotension episode in relation to umbilical pH (r = -0.817, -0.395 and -0.268, respectively). Cut off value for induction of spinal anesthesia to delivery interval greater than 27 min predicted an umbilical pH of < 7.2. Cut off value for the duration of the longest hypotension episode greater than 5 min predicted an umbilical pH of < 7.2. Cut off value for BMI greater than 35 kg/m2 predicted an umbilical pH of < 7.2. Prolonged interval between induction of spinal anesthesia to delivery could be associated with neonatal acidosis. This could be aggravated by maternal obesity and prolonged duration of hypotension episodes during cesarean delivery.

1 October 2016 in Reproductive Sciences
Verified
Journal Article
Closed access
AEAhmed M. Bahaa Eldin
Ahmed M. Bahaa Eldin
KAKarim H. Abdelmaabud
Karim H. Abdelmaabud
Mohamed LabanMohamed Laban
Mohamed Laban
AHAlaa S. Hassanin
Alaa S. Hassanin
ATAhmed A. Tharwat
Ahmed A. Tharwat
IAIbrahim Abdelhady
Ibrahim Abdelhady

12 October 2017 in The Journal of Maternal-Fetal & Neonatal Medicine
Verified
Journal Article
Closed access
Mohamed LabanMohamed Laban
Mohamed Laban
GMGhada M. Mansour
Ghada M. Mansour
AEAhmed El-Kotb
Ahmed El-Kotb
AHAlaa Hassanin
Alaa Hassanin
ZLZina Laban
Zina Laban
ASAbdelrahman Saleh
Abdelrahman Saleh
Objective: The objective of this study is to estimate optimal cut-off values for mean fetal lung volume (FLV) and pulmonary artery resistance index (PA-RI) as non-invasive measures to predict neonatal respiratory distress syndrome (RDS) in preterm fetuses. Methods: A prospective study conducted at Ain Shams University Maternity Hospital, Egypt from May 2015 to July 2017: 80 eligible women diagnosed with preterm labor were recruited at 32–36 weeks’ gestation. Before delivery, three-dimensional ultrasound was used to estimate FLV using virtual organ computer-aided analysis (VOCAL), while PA-RI was measured by Doppler ultrasonography. Results: A total of 80 women were examined. Thirty-seven (46%) of the newborns developed neonatal RDS. FLV was significantly lower in neonates who developed RDS (p = .04), whereas PARI was significantly higher in those who did not (p = .02). Cut-off values of FLV ≤27.2 cm3 and PARI ≥0.77 predicted the subsequent development of RDS. Combining both cut-offs generated a more sensitive and specific methodical approach for the prediction of RDS (sensitivity 100%, specificity 88.5%). Conclusion: Measurement of FLV or PA-RI can predict RDS in preterm fetuses. Combined use of both measures bolstered their predictive significance.