Jacob Ostergaard

Jacob Ostergaard

Auto-generated profile, based on publicly available information

Jacob Ostergaard

Technical University of Denmark, Denmark

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2009 in Electric Power Systems Research
Verified
Journal Article
Closed access
KDK.C. Divya
K.C. Divya
JØJacob Østergaard
Jacob Østergaard

1 January 2015 in Applied Energy
Verified
Journal Article
Closed access
QWQi Wang
Qi Wang
CZChunyu Zhang
Chunyu Zhang
YDYi Ding
Yi Ding
George XydisGeorge Xydis
George Xydis
JWJianhui Wang
Jianhui Wang
JØJacob Østergaard
Jacob Østergaard

23 December 2011 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
LYLihui Yang
Lihui Yang
ZXZhao Xu
Zhao Xu
JOJacob Ostergaard
Jacob Ostergaard
Zhaoyang DongZhaoyang Dong
Zhaoyang Dong
KWKit Po Wong
Kit Po Wong
This paper presents an advanced control strategy for the rotor and grid side converters of the doubly fed induction generator (DFIG) based wind turbine (WT) to enhance the low-voltage ride-through (LVRT) capability according to the grid connection requirement. Within the new control strategy, the rotor side controller can convert the imbalanced power into the kinetic energy of the WT by increasing its rotor speed, when a low voltage due to a grid fault occurs at, e.g., the point of common coupling (PCC). The proposed grid side control scheme introduces a compensation term reflecting the instantaneous DC-link current of the rotor side converter in order to smooth the DC-link voltage fluctuations during the grid fault. A major difference from other methods is that the proposed control strategy can absorb the additional kinetic energy during the fault conditions, and significantly reduce the oscillations in the stator and rotor currents and the DC bus voltage. The effectiveness of the proposed control strategy has been demonstrated through various simulation cases. Compared with conventional crowbar protection, the proposed control method can not only improve the LVRT capability of the DFIG WT, but also help maintaining continuous active and reactive power control of the DFIG during the grid faults.

13 November 2013 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
JHJunjie Hu
Junjie Hu
SYShi You
Shi You
MLMorten Lind
Morten Lind
JOJacob Ostergaard
Jacob Ostergaard
Distributed energy resources (DERs), like electric vehicles (EVs), can offer valuable services to power systems, such as enabling renewable energy to the electricity producer and providing ancillary services to the system operator. However, these new DERs may challenge the distribution grid due to insufficient capacity in peak hours. This paper aims to coordinate the valuable services and operation constraints of three actors: the EV owner, the Fleet operator (FO) and the Distribution system operator (DSO), considering the individual EV owner's driving requirement, the charging cost of EV and thermal limits of cables and transformers in the proposed market framework. Firstly, a theoretical market framework is described. Within this framework, FOs who represent their customer's (EV owners) interests will centrally guarantee the EV owners' driving requirements and procure the energy for their vehicles with lower cost. The congestion problem will be solved by a coordination between DSO and FOs through a distribution grid capacity market scheme. Then, a mathematical formulation of the market scheme is presented. Further, some case studies are shown to illustrate the effectiveness of the proposed solutions.

6 January 2011 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
LYLihui Yang
Lihui Yang
ZXZhao Xu
Zhao Xu
JØJacob Østergaard
Jacob Østergaard
Zhaoyang DongZhaoyang Dong
Zhaoyang Dong
KWKit Po Wong
Kit Po Wong
XMXikui Ma
Xikui Ma
This paper focuses on modeling and oscillatory stability analysis of a wind turbine with doubly fed induction generator (DFIG). A detailed mathematical model of DFIG wind turbine with vector-control loops is developed, based on which the loci of the system Jacobian's eigenvalues have been analyzed, showing that, without appropriate controller tuning a Hopf bifurcation can occur in such a system due to various factors, such as wind speed. Subsequently, eigenvalue sensitivity with respect to machine and control parameters is performed to assess their impacts on system stability. Moreover, the Hopf bifurcation boundaries of the key parameters are also given. They can be used to guide the tuning of those DFIG parameters to ensure stable operation in practice. The computer simulations are conducted to validate the developed model and to verify the theoretical analysis.

4 February 2013 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
DXDongliang Xie
Dongliang Xie
ZXZhao Xu
Zhao Xu
LYLihui Yang
Lihui Yang
JOJacob Ostergaard
Jacob Ostergaard
YXYusheng Xue
Yusheng Xue
KWKit Po Wong
Kit Po Wong
The paper presents a new control strategy to enhance the ability of reactive power support of a doubly fed induction generator (DFIG) based wind turbine during serious voltage dips. The proposed strategy is an advanced low voltage ride through (LVRT) control scheme, with which a part of the captured wind energy during grid faults is stored temporarily in the rotor's inertia energy and the remaining energy is available to the grid while the DC-link voltage and rotor current are kept below the dangerous levels. After grid fault clearance, the control strategy ensures smooth release of the rotor's excessive inertia energy into the grid. Based on these designs, the DFIG's reactive power capacity on the stator and the grid side converter is handled carefully to satisfy the new grid code requirements strictly. Simulation studies are presented and discussed.