Rasmus Thalund-Hansen

Rasmus Thalund-Hansen

Auto-generated profile, based on publicly available information

Rasmus Thalund-Hansen

Department of Environmental and Resource Engineering, Technical University of Denmark, Lyngby, Denmark

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2022 in Water Resources Research
Verified
Journal Article
Open access
LLL. Lévy
L. Lévy
RTR. Thalund‐Hansen
R. Thalund‐Hansen
TBT. Bording
T. Bording
GFG. Fiandaca
G. Fiandaca
ACAnders Vest Christiansen
Anders Vest Christiansen
PBP. L. Bjerg
P. L. Bjerg
In situ remediation of contaminated groundwater often relies on the installation of a treatment zone (TZ) degrading the contamination. Zero‐valent‐iron (ZVI) is a type of reagent used for this purpose. Adequate delivery of ZVI in the whole target volume is particularly challenging and requires monitoring with high spatial resolution. We present a monitoring tool for imaging the dynamic spreading of ZVI and its associated ionic cloud, using cross‐borehole time‐lapse electrical resistivity tomography (ERT). This tool works in urban areas and is particularly suitable for achieving the required spatial resolution at the scale of the target volume. Groundwater and sediment samples show a consistent spatial and temporal distribution of the remediation cloud with cross‐borehole ERT. Yet, the 2D anomalies observed with cross‐borehole ERT provide a more spatially complete and rapid image of the remediation cloud distribution than if based solely on monitoring screens. At the study site, ZVI injection leads to uneven spreading, clearly documented by cross‐borehole ERT monitoring. The benefit of hydraulic conductivity (K) mapping by cross‐borehole induced polarization (IP) to understand unexpected injection paths (upstream leakage, spreading in preferred pathways) is investigated. A 2D, IP‐based, continuous, and coherent K‐distribution is obtained that compares well with estimations by grain size analyses from the TZ. However, the IP‐based K‐field fails at predicting injection paths, suggesting the creation of pathways during the high‐pressure injection of ZVI. Cross‐borehole time‐lapse ERT is the most promising geophysical tool for performance assessment of in situ remediation involving reagents with conductivity contrast.

22 August 2023 in Water Resources Research
Verified
Journal Article
Open access
RTRasmus Thalund‐Hansen
Rasmus Thalund‐Hansen
MTMads Troldborg
Mads Troldborg
LLLéa Levy
Léa Levy
ACAnders Vest Christiansen
Anders Vest Christiansen
TBThue S. Bording
Thue S. Bording
PBPoul L. Bjerg
Poul L. Bjerg
A new methodology was developed to support contaminant mass discharge (CMD)‐based risk assessment of groundwater contamination downgradient of point source zones. Geoelectrical cross‐borehole induced polarization (IP) data were collected at a site undergoing in situ remediation of chlorinated solvents for determining 2D hydraulic conductivity (K) distributions with an inversion model resolution of 0.15 m (vertically) x 0.50 m (horizontally) in three control planes from 10 to 20 m depth. Additionally, 18 slug tests and 31 grain size distribution analyses (GSA) from the control planes, were used for K‐estimation. The geometric means and variance of the IP, slug test, and GSA derived K‐estimates were consistent with previously studied sandy aquifers. Furthermore, the vertical variation in K between two geological settings, a sandy till and a meltwater sand formation, was clearly identified by the IP K‐estimates. The vertical variation was backed up by hydraulic profiling tool (HPT) measurements. Random realizations of CMD were simulated based on the cross‐borehole IP derived K‐values. For comparison, the CMD was also estimated with a geostatistical conditional simulation approach, using the data from slug tests and GSAs. The high IP resolution captured the small scale variations in K across the transects and led to CMD predictions with a narrow uncertainty interval, whereas slug test and GSA either under‐ or overestimated the magnitude of the areas with the highest CMD. Applying the geophysical cross‐borehole method for estimating K‐distributions in addition to traditional methods would improve CMD‐based risk assessment and evaluation of remediation performance at contaminated sites.

28 May 2026 in Nature Communications
Verified
Journal Article
Open access
PJPeter R. Jørgensen
Peter R. Jørgensen
KMKlaus Mosthaf
Klaus Mosthaf
PKPaul Henning Krogh
Paul Henning Krogh
AHAnders J. Hansen
Anders J. Hansen
INIda Nielsen
Ida Nielsen
MRMassimo Rolle
Massimo Rolle
Glacial aquitards from the last Pleistocene glaciation cover vast areas of the Northern Hemisphere. Due to their clay-rich composition, these aquitards are considered to protect underlying aquifers from surface contaminations, provided they are not penetrated by widespread deep fractures. In this study we combine ancient DNA (aDNA) with detailed hydrological techniques to investigate contaminant transport in the aquitards - an interdisciplinary approach that was not possible when the current understanding of the dominant role of fractures was established. We show that deep fractures (> 2 m below surface) in the glacial aquitards across Denmark are closed or marginal as pathways of dissolved contaminant transport unless they contain flow channels from deep modern and ancient tree roots. Our study reveals that deep tree roots can compromise natural groundwater protection and accelerate groundwater pollution by opening fractures and generating deep macropores. The results highlight that thorough attention needs to be paid to land-use history and widespread legacy and future soil pollution prior to reforestation and afforestation of aquitards above drinking water resources. We furthermore demonstrate that the protection of aquitard areas with less thickness than historical rooting depths and high degrees of lithological heterogeneity (related to aquitard glacial till types) is crucial to preserve drinking water resources and to restore groundwater quality beneath glacial aquitards.

28 March 2022
Verified
Conference Paper
Open access
RTRasmus Thalund-Hansen
Rasmus Thalund-Hansen
LLLéa Levy
Léa Levy
ACAnders Vest Christiansen
Anders Vest Christiansen
TBThue Bording
Thue Bording
KRKirsten Rügge
Kirsten Rügge
PBPoul L. Bjerg
Poul L. Bjerg
BackgroundEvolving In situ methods are showing results for sustainable and efficient plume remediation of groundwater contaminations. By injecting reactive components such as oxidation agents, zero valent iron, substrate and/or bacteria, a treatment zone (TZ) is established. In the TZ, the contamination degrades into harmless components by chemical and/or biological processes. Successful in situ remediation depends on contact between injectants and contamination. Yet, monitoring the spreading of the injectant is difficult by point sampling. The cross-borehole geophysical method DCIP (Direct Current, Induced Polarisation) allows for detailed spatial information on subsurface electrical resistivity and induced polarisation properties. The information can be used to assess the success of the injection and the development over time. Furthermore, the IP properties can be used to infer spatial information on hydraulic conductivity, which can be used in planning of the in situ remediation and in quantification of contaminant mass discharge (CMD) at the site. The objective of this study is to develop a cost-efficient method for detailed spatial and temporal monitoring of in situ remediation and to develop better tools to retrieve spatial subsurface information, able to assist and improve CMD based monitoring. ApproachA TZ in a plume of chlorinated ethenes was established by injecting the micro zerovalent iron product and a bacterial culture into the groundwater. A network of 9 geophysical and 16 monitoring wells was established. Cross-borehole DCIP measurements and water samples were taken before and shortly after injection and during the following year. Soil cores were sampled for chemical analysis of iron shortly after injection, and slug tests and grain size analysis. Data from water samples, soil cores and hydraulic tests were compared to the geophysical measurements to assess correlation between water chemistry and electrical resistivity from cross-borehole DCIP. The hydraulic properties inferred from hydraulic tests and cross-borehole DCIP were compared. The hydraulic properties with uncertainties and the contamination data were used to estimate the CMD through the TZ. Results The changes in electrical conductivity and specific water quality parameters caused by the injection, showed a strong correlation with the geophysical model. The observed correlation enabled a coherent, detailed understanding of both spatial and temporal spreading of the injected components, resulting in a re-injection. Hydraulic tests and hydraulic properties inferred from cross borehole DCIP showed a very good correlation, and applying the hydraulic properties inferred from cross borehole DCIP reduced the uncertainty of the CMD estimate before and after injection. In conclusion, cross borehole DCIP has the potential to improve planning and monitoring of in situ groundwater remediation and to reduce uncertainty of CMD estimation and thereby strengthen CMD as a metric in risk assessment.