6 May 2021 in IEEE Transactions on Power Electronics
This article presents a critical conduction mode (CRM) single-phase transformerless full-bridge inverter in a residential photovoltaic system. The CRM full-bridge inverter in bipolar mode features zero-voltage switching capability for the whole line cycle. This enables the inverter to push switching frequency up to hundreds of kHz and achieve high power density with high efficiency. However, CRM operation incurs nonconstant common mode (CM) voltage during the resonant period, causing high frequency leakage current. To minimize the leakage current, a new switching modulation strategy is proposed introducing triangular current mode (TCM) near the ac voltage zero crossing. The switching modulation scheme alleviates the CM voltage by shortening the resonant period and consequently reduces the leakage current. Then, discontinuous conduction mode is inserted between the CRM and TCM operation regions to improve light load efficiency. In this article, the basic operation principle of the CRM full-bridge inverter, impacts of CRM operation on the leakage current, and details of the proposed switching modulation method are discussed. Experimental results with a 2.4-kW prototype built with GaN devices validate its performance.
23 May 2022 in IEEE Transactions on Power Electronics
This article presents the design and analysis of a double-side-cooled printed circuit board (PCB) embedded silicon carbide (SiC) MOSFET half-bridge package with low loop inductances and an integrated gate driver. The 1.2 kV SiC MOSFET dies used in the half-bridge package are embedded in the PCB using AT&S's patented technique. The dies are cooled and electrically connected to traces in the PCB through copper-filled microvias. The design methodology accounts for both electrical and thermal performance, limiting the power-loop inductance to 2.3 nH and the maximum package temperature to less than the 175 °C limit. The integration of the gate drive circuitry allows for a high power density and 2.2 nH gate-loop inductances. At 0.12 K/W, the measured junction-to-case thermal resistance with double-sided cooling is 57% lower than that of a TO-247 package. Under similar operating conditions, the PCB-embedded half-bridge package also achieves a 5.6 times lower voltage overshoot and a 0.5% higher peak efficiency than a TO-247-based half-bridge. This article reports the first demonstration of PCB-embedded 1.2 kV SiC MOSFET packages in buck, boost, and ac–dc converters. The prototype three-phase ac–dc converter for an electric vehicle on-board charger is composed of six PCB-embedded half-bridge packages and achieves an efficiency of 98.2% and a power density of 182 W/in 3 .
15 March 2017 in IEEE Transactions on Power Electronics
This paper proposes an improved modulated carrier control with on-time doubler for the single-phase shunt active power filter, which eliminates harmonic and reactive currents drawn by nonlinear loads. This control method directly shapes the line current to be sinusoidal and in phase with the grid voltage by generating a modulated carrier signal with a resettable integrator, comparing the carrier signal to the average line current and making duty ratio doubled. Since the line current compared to the carrier signal is not the peak, but the average value, dc-offset appeared at the conventional control methods based on one-cycle control is effectively addressed. The proposed control technique extirpates the harmonic and reactive currents and solves the dc-offset problem. The operation principle and stability characteristic of the single-phase shunt active power filter with the proposed control method are discussed, and experimental results with laboratory prototype under various load conditions verify its performance.
18 July 2022 in IEEE Transactions on Power Electronics
This article presents a PCB winding coupled inductor design for both high efficiency and effective common-mode (CM) noise reduction in a silicon carbide (SiC)-based soft-switching three-phase ac–dc converter. A balance technique is applied to reduce the CM noise, creating a return path with additional inductors. The inductors in the main circuit and return path are coupled in one core and implemented with PCB windings. A winding interleaving structure with strong coupling between the main inductors is selected to minimize the winding loss and to improve the converter efficiency; however, the interwinding capacitance brought on by the winding interleaving worsens the CM noise. An inductor model including the capacitance is introduced, and its impact on the CM noise is analyzed. A novel inductor structure is proposed to scale back the interwinding capacitance and to enhance the CM noise reduction capability. Experiments with a SiC-based 25-kW soft-switching three-phase ac–dc converter prototype validates the performances of the proposed PCB winding coupled inductors.
11 January 2022 in IEEE Transactions on Power Electronics
This article presents control techniques for the critical conduction mode(CRM) based high-frequency soft-switching three-phase inverter under unbalanced grid conditions. The soft-switching technique with silicon carbide (SiC) power devices allows the inverter to operate at hundreds of kHz with high efficiency and high power density. To extend the soft-switching technique to more practical cases, behaviors of the inverter under unbalanced grid conditions, specifically voltage sag, are investigated. During the voltage sag, the ac voltage at the grid becomes unbalanced. This requires unbalanced ac current reference to avoid output active power oscillation. With the unbalanced grid voltage and the ac current reference, the inverter loses the soft-switching capability. Continuous conduction mode (CCM) operation occurs where discontinuous conduction mode (DCM) operation is intended leading to large turn- on loss. To eliminate the CCM issue, two improved modulation techniques are proposed by using off -time extension in the CRM phase and by skipping pulses in the DCM phase. This article discusses how the CCM operation arises and details the proposed control methods. The performance of the proposed control is validated experimentally under a variety of grid imbalance cases with an SiC-based three-phase inverter prototype.
24 September 2021 in IEEE Transactions on Power Electronics
In this article, balance technique is applied into two-channel interleaved three-phase ac–dc converters with critical conduction mode based soft switching modulation. By adding additional inductors and coupling them with the original ones, the realization of the balance becomes possible with proper design; thus reducing the common-mode (CM) EMI noise. The balance condition is derived, and the impact of balance technique on the circuit operation especially on the switching frequency variation is quantified in order to provide the design guideline. Based on the application of balance technique, instead of the commonly used litz-wire-based inductors, PCB winding coupled inductors are adopted and designed to effectively achieve the reduction of CM EMI noise. The design methodology and process are presented, and the design tradeoff is made between the inductor loss and the inductor footprint. Finally, the effect of CM EMI noise reduction and the system efficiency with balance techniques and PCB winding magnetics are tested on a 25-kW silicon-carbide-based soft-switching three-phase ac–dc converter prototype.