In this paper, a novel critical-conduction-mode (CRM)-based modulation is proposed for three-phase bi-directional AC/DC converters. With this modulation, the switching frequency variation range shrinks, zero-voltage-switch (ZVS) soft switching is achieved and the switching related loss is reduced, which is especially beneficial for systems operating above hundreds of kHz high switching frequency with wide-band-gap (WBG) power semiconductor devices to achieve both high power density and high efficiency. A 25 kW SiC-based high-frequency three-phase bi-directional AC/DC converter prototype is designed to achieve a power density of 127 W/in, which is at least five times higher than commercial products. All the control functions are digitally implemented with one low-cost microcontroller (MCU), and the aforementioned benefits are experimentally verified on this prototype under both inverter mode and rectifier mode operations. With the proposed soft-switching modulation, the tested peak efficiency is close to 99.0% for this prototype even at above 300 kHz high switching frequency operation.
6 May 2021 in IEEE Transactions on Power Electronics
This article presents a critical conduction mode (CRM) single-phase transformerless full-bridge inverter in a residential photovoltaic system. The CRM full-bridge inverter in bipolar mode features zero-voltage switching capability for the whole line cycle. This enables the inverter to push switching frequency up to hundreds of kHz and achieve high power density with high efficiency. However, CRM operation incurs nonconstant common mode (CM) voltage during the resonant period, causing high frequency leakage current. To minimize the leakage current, a new switching modulation strategy is proposed introducing triangular current mode (TCM) near the ac voltage zero crossing. The switching modulation scheme alleviates the CM voltage by shortening the resonant period and consequently reduces the leakage current. Then, discontinuous conduction mode is inserted between the CRM and TCM operation regions to improve light load efficiency. In this article, the basic operation principle of the CRM full-bridge inverter, impacts of CRM operation on the leakage current, and details of the proposed switching modulation method are discussed. Experimental results with a 2.4-kW prototype built with GaN devices validate its performance.
4 November 2019 in IEEE Transactions on Power Electronics
In this paper, an improved critical-conduction-mode (CRM)-based soft-switching modulation technique is proposed for three-phase photovoltaic (PV) inverter applications under not only the unity power factor operating condition but also non-unity power factor operating conditions in order to reduce switching loss. With the proposed improvements, for the typical power factor range from the 0.8 lagging condition to the 0.8 leading condition in PV applications, zero-voltage-switch (ZVS) turn-on or valley drain-source voltage turn-on is achieved, which is especially beneficial for silicon carbide (SiC)-based systems at high switching frequency operation to achieve not only high power density but also high efficiency. The proposed modulation technique is digitally implemented with one low-cost microcontroller (MCU). The capability of reactive power transfer and benefits of the improved modulation for achieving soft switching under non-unity power factor conditions are experimentally verified on a SiC-based three-phase bidirectional ac-dc converter prototype. The tested peak efficiency is 98.9% under the unity power factor operation, and above 98.0% within the aforementioned typical power factor range in PV applications, at above 300 kHz switching frequency operation.
24 September 2021 in IEEE Transactions on Power Electronics
In this article, balance technique is applied into two-channel interleaved three-phase ac–dc converters with critical conduction mode based soft switching modulation. By adding additional inductors and coupling them with the original ones, the realization of the balance becomes possible with proper design; thus reducing the common-mode (CM) EMI noise. The balance condition is derived, and the impact of balance technique on the circuit operation especially on the switching frequency variation is quantified in order to provide the design guideline. Based on the application of balance technique, instead of the commonly used litz-wire-based inductors, PCB winding coupled inductors are adopted and designed to effectively achieve the reduction of CM EMI noise. The design methodology and process are presented, and the design tradeoff is made between the inductor loss and the inductor footprint. Finally, the effect of CM EMI noise reduction and the system efficiency with balance techniques and PCB winding magnetics are tested on a 25-kW silicon-carbide-based soft-switching three-phase ac–dc converter prototype.
18 March 2022 in IEEE Transactions on Power Electronics
This article explores how to improve the light load efficiency of a critical conduction mode (CRM)-based two-channel paralleled soft-switching three-phase inverter. Although the CRM-based soft-switching scheme achieves high efficiency at heavy load, the efficiency drops rapidly as the output power decreases. Its CRM-based operation makes the switching frequency soar because of the small inductor currents at light load giving rise to the high switching-related loss. To enlarge the inductor current handled by the first channel of the inverter, a phase shedding control is proposed to not excite gate signals for the second channel, thus bringing the first channel's frequency down. The phase shedding is put into effect to only two phases in the second channel running at high frequency to circumvent the undesired circulating current in the two-channel paralleled inverter structure. In addition, for very light load conditions (below 10%), frequency limiting methods are introduced in conjunction with the phase shedding to further improve the efficiency. Experimental results with a 25-kW SiC-based inverter prototype verify that the phase shedding control improves the light load efficiency by 0.5 to 3.9%. It is further improved by 0.3 to 1.3% with the frequency limiting under very light load conditions.