6 December 2023 in Biomedical Optics Express
Quantitative phase microscopy (QPM) is indispensable in biomedical research due to its advantages in unlabeled transparent sample thickness quantification and obtaining refractive index information. Fourier ptychographic microscopy (FPM) is among the most promising QPM methods, incorporating multi-angle illumination and iterative phase recovery for high-resolution quantitative phase imaging (QPI) of large cell populations over a wide field of-view (FOV) in a single pass. However, FPM is limited by data redundancy and sequential acquisition strategies, resulting in low imaging efficiency, which in turn limits its real-time application in in vitro label-free imaging. Here, we report a fast QPM based on Fourier ptychography (FQP-FPM), which uses an optimized annular downsampling and parallel acquisition strategy to minimize the amount of data required in the front end and reduce the iteration time of the back-end algorithm (3.3% and 4.4% of conventional FPM, respectively). Theoretical and data redundancy analyses show that FQP-FPM can realize high-throughput quantitative phase reconstruction at thrice the resolution of the coherent diffraction limit by acquiring only ten raw images, providing a precondition for in vitro label-free real-time imaging. The FQP-FPM application was validated for various in vitro label-free live-cell imaging. Cell morphology and subcellular phenomena in different periods were observed with a synthetic aperture of 0.75 NA at a 10× FOV, demonstrating its advantages and application potential for fast high-throughput QPI.
18 December 2023 in Optics Express
Fourier ptychographic microscopy (FPM) is used to achieve high resolution and a large field of view. However, traditional FPM image reconstruction methods often yield poor image quality when encountering out-of-focus issues during reconstruction. Therefore, this study proposes a defocus-distance regression network based on convolutional neural networks. In an experimental validation, the root-mean-square error calculated from 1000 sets of predicted and true values was approximately 6.2 µm. The experimental results suggest that the proposed method has good generalization, maintains high accuracy in predicting defocus distances even for different biological samples, and extends the imaging depth-of-field of the FPM system by a factor of more than 3.
1 March 2023 in Journal of Biomedical Optics
SignificanceFourier ptychographic microscopy (FPM) enables quantitative phase imaging with a large field-of-view and high resolution by acquiring a series of low-resolution intensity images corresponding to different spatial frequencies stitched together in the Fourier domain. However, the presence of various aberrations in an imaging system can significantly degrade the quality of reconstruction results. The imaging performance and efficiency of the existing embedded optical pupil function recovery (EPRY-FPM) aberration correction algorithm are low due to the optimization strategy.AimAn aberration correction method (AA-P algorithm) based on an improved phase recovery strategy is proposed to improve the reconstruction image quality.ApproachThis algorithm uses adaptive modulation factors, which are added while updating iterations to optimize the spectral function and optical pupil function updates of the samples, respectively. The effectiveness of the proposed algorithm is verified through simulations and experiments using an open-source biological sample dataset.ResultsExperimental results show that the proposed AA-P algorithm in an optical system with hybrid aberrations, recovered complex amplitude images with clearer contours and higher phase contrast. The image reconstruction quality was improved by 82.6% when compared with the EPRY-FPM algorithm.ConclusionsThe proposed AA-P algorithm can reconstruct better results with faster convergence, and the recovered optical pupil function can better characterize the aberration of the imaging system. Thus, our method is expected to reduce the strict requirements of wavefront aberration for the current FPM.
1 November 2023 in Journal of Biomedical Optics
Optical microscopic imaging is an important technical tool in many fields, such as life sciences and biomedicine. Traditional optical microscopes are limited by the space-bandwidth product (SBP)1 of the optical imaging system and cannot simultaneously achieve a large field of view (FOV) and high-resolution (HR) imaging at the same time. Fourier ptychographic microscopy (FPM) is an emerging computational imaging technology that usually uses the combination of an optical microscope and a light emitting diode (LED) illumination array (programmable control) and combines phase recovery2 – 4 and the synthetic aperture principle5 – 8 to restore the HR intensity and phase image of the sample. To a certain extent, it overcomes the limitations of traditional optical microscopes of the difficulty they face in balancing a large FOV and HR imaging, and thus constitutes an improvement over traditional optical microscopy. In contrast to traditional optical microscopes, FPM transfers the high-frequency information in an object that initially surpasses the system cutoff frequency to within the passband of the system through multi-angle illumination,9 collects a series of low-resolution (LR) images at the camera side, and then uses a phase recovery algorithm to stitch them in the frequency domain to achieve large SBP and quantitative phase imaging.10 The summation of the numerical aperture of the objective () and the numerical aperture of illumination () determines the reconstruction resolution.11 Simultaneously achieving a large FOV and HR imaging has significance in microscopic imaging. Therefore, FPM-related theories and technologies have been widely researched and applied in the fields of digital microscopy and life sciences.12 – 15
2 June 2025 in Biomedical Optics Express
The recent Fourier ptychographic microscopy (FPM) for computational optical super-resolution imaging achieves a large field of view and high resolution without relying on precision instruments. However, current FPM requires extensive raw image acquisition for reconstruction, thus reducing the imaging efficiency. We propose a quantitative phase imaging method that combines bright-field annular-matched illumination with dark-field parallel-coded illumination. Based on parallel-coding illumination theory, our illumination scheme integrates single LED activation in bright-field annular-matched illumination and parallel LED activation in dark-field illumination, drastically reducing the data acquisition requirements for FPM reconstruction. Experimental results demonstrate that our combined FPM method acquires only eight raw images to realize fast quantitative phase imaging with a resolution three times the coherent diffraction limit, which improves the imaging efficiency by 50% compared with the traditional annular downsampling. Moreover, only 3.5% of the data for conventional FPM is required, substantially accelerating raw data acquisition and high-resolution image reconstruction. Our efficient FPM method can enable real-time dynamic imaging of living cells.