Donglan Zou

Donglan Zou

Auto-generated profile, based on publicly available information

Donglan Zou


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2025 in Biomedical Optics Express
Verified
Journal Article
Closed access
JHJiawei He
Jiawei He
ZLZicong Luo
Zicong Luo
MLMingdi Liu
Mingdi Liu
LJLiang Junzhao
Liang Junzhao
XRXie Rui
Xie Rui
YWYanxiong Wu
Yanxiong Wu
The recent Fourier ptychographic microscopy (FPM) for computational optical super-resolution imaging achieves a large field of view and high resolution without relying on precision instruments. However, current FPM requires extensive raw image acquisition for reconstruction, thus reducing the imaging efficiency. We propose a quantitative phase imaging method that combines bright-field annular-matched illumination with dark-field parallel-coded illumination. Based on parallel-coding illumination theory, our illumination scheme integrates single LED activation in bright-field annular-matched illumination and parallel LED activation in dark-field illumination, drastically reducing the data acquisition requirements for FPM reconstruction. Experimental results demonstrate that our combined FPM method acquires only eight raw images to realize fast quantitative phase imaging with a resolution three times the coherent diffraction limit, which improves the imaging efficiency by 50% compared with the traditional annular downsampling. Moreover, only 3.5% of the data for conventional FPM is required, substantially accelerating raw data acquisition and high-resolution image reconstruction. Our efficient FPM method can enable real-time dynamic imaging of living cells.

9 April 2026 in Applied Optics
Verified
Journal Article
Closed access
HLHongbo Li
Hongbo Li
HLHongan Lin
Hongan Lin
LLLintong Lin
Lintong Lin
XZXiyi Zhou
Xiyi Zhou
YLYinghong Liu
Yinghong Liu
YWYanxiong Wu
Yanxiong Wu
In space-based gravitational-wave observatories, tilt-to-length (TTL)-coupled noise represents a critical limitation, ranking as the second-largest noise contribution after shot noise. Suppressing this noise in large-aperture telescopes, which typically exhibit high TTL coupling coefficients, remains a significant challenge due to the absence of a generalized suppression methodology. This work introduces a comprehensive design strategy to directly mitigate TTL-coupled noise in such systems. A wavefront aberration contribution model based on Zernike coefficients is established, and a hierarchical optimization strategy is introduced, in which lower-order aberrations are controlled based on their contribution to the total root mean square, whereas adaptive weights are assigned to higher-order aberrations. An optimization metric centered on the TTL-coupled noise coefficient is formulated, establishing a direct link between optical performance and noise suppression. The method is applied to design an off-axis four-mirror optical system. Aberration contribution ratios are quantified, hierarchical optimization weights assigned, and 24 sampling zones defined to compute the TTL noise coefficient. This coefficient guides optimization via a custom evaluation function implemented in Zemax. Simulations confirm the method’s efficacy: under identical disturbance conditions, the TTL-coupled noise coefficient is reduced from 50.9519 pm/µrad to 0.0441 pm/µrad—a suppression exceeding 99%. This approach markedly enhances detection sensitivity and offers a generalizable framework for the design of high-precision space gravitational-wave telescopes.