13 July 2022 in IEEE Transactions on Industrial Electronics
This article proposes pulse width modulation (PWM) methods for low inductance brushless dc (BLDC) motor drives that minimize the commutation torque ripples. An uneven current of noncommutation phase generates the commutation torque ripples. In the low inductance BLDC motor drives, two types of time delays in PWM also induce critical torque ripples. In this article, the analyses of the time delays in PWM and their effects are introduced. Then, two PWM methods are proposed to eliminate the time delays in the commutation region and the conduction region, respectively. The commutation period is controlled to be synchronized to the switching period. In addition, the proposed methods synchronize the switching period to the commutation interrupt. As a result, the proposed methods effectively maintain the minimum commutation period as well as minimize the commutation torque ripples in the low inductance BLDC motor drives. The validity of the proposed methods is demonstrated by the simulation and experimental results in various driving conditions. The results show that the commutation period is remarkably shortened and the commutation torque ripples are reduced by 27.6% in comparison to the conventional method.
15 May 2023 in IEEE Transactions on Industrial Electronics
In vector-controlled drive systems, a position sensorless drive with a single current sensor (SD-SCS) is an attractive system due to the minimum number of sensors. However, when the saliency-based SD-SCS is applied, the position estimation accuracy is deteriorated due to the errors in the injected pulsewidth-modulated voltage and the reconstructed current. This article proposes a current-derivative-based sensorless control using a three active vector pulsewidth modulation (TAVPWM) to enhance the saliency-based SD-SCS. First, the TAVPWM scheme, which eliminates the current reconstruction dead zone in the low-modulation region, is adopted to improve the low-speed drive. Next, the derivatives of the phase currents are utilized and analyzed to minimize the position estimation error in the overall operating regions. Finally, the transition strategy with respect to the speed is proposed for the full-speed sensorless drive. Owing to the proposed method, the switching frequency increases up to 16 kHz and the audible noise is virtually eliminated in the saliency-based SD-SCS. Furthermore, the enhanced dynamic performance is verified by various experimental results.
29 February 2024 in IEEE Transactions on Industrial Electronics
Position sensorless drive with single current sensor (SD-SCS) is widely utilized in cost-effective applications. The drive performance of saliency-based SD-SCS can be easily deteriorated due to several reasons: inaccurate phase current reconstruction (PCR) and the interference in injected voltages for the PCR and position estimation. Here, this article proposes an enhanced sensorless control strategy employing six-vertex voltage injection for PCR and position estimation. First, the parameter dependency in position estimation is eliminated by using the current derivative measurements at six active vectors. In addition, by modifying the sequence of voltage vectors, the proposed pulsewidth modulation scheme reduces the current ripple caused by the injected voltages. Experimental results verify that the proposed method shows high accuracy of position estimation and significantly reduces the total harmonic distortion of the phase current in SD-SCS, making it comparable to that of a position-sensored drive.
24 September 2024 in IEEE Transactions on Industrial Electronics
Voltage source inverters (VSIs) are widely used in electric vehicle due to their high control performance and efficiency in electric motor drive systems. However, the output voltage of the inverter during switching instances generates bearing currents, leading to bearing damage. This article analyzes the relationship between bearing currents and bearing damage, and proposes a new method for reducing bearing currents. First, a precise bearing current measurement system using a current transformer is introduced. This system verifies the phenomenon of bearing damage caused by bearing currents at low speeds. Fourier transform analysis of audio signals from bearings is employed to confirm this phenomenon. Subsequently, a two-phase pulse-width modulation (PWM) method that considers the saliency of interior permanent magnet synchronous machines (IPMSMs) and a capacitive filter topology is presented. The proposed method is validated through experimental results in a commercial electric vehicle drive system. As a result, the bearing current is reduced by 91% compared to that of space vector PWM (SVPWM) method.
2 April 2024 in IEEE Transactions on Industry Applications
In capacitive power transfer systems, coupling variation inevitably occurs due to air gap variation and coupler misalignment. This paper presents a single-sided compensation network design method for capacitive power transfer systems considering coupling variation. The proposed method adopts a single-sided compensation network to reduce the volume and weight of the receiver side circuit. The proposed compensation network, within a preselected narrow operational frequency range, effectively transforms the variable load impedance into a single resistive point, resulting in constant output power and zero-phase angle operation under coupling variation. The proposed method employs the impedance matching network design based on a twoport network analysis. The validity of the proposed design method is confirmed with a simulation and a 1.2 kW small air gap capacitive power transfer system prototype. The experimental prototype system achieved a maximum efficiency of 91.2% under no misalignment and a minimum efficiency of 89.9% under a maximum 40% area displacement in coupling conductor plates, with a near-constant output power and zero-phase angle operation
2 November 2022 in IEEE Transactions on Industrial Electronics
In the field-oriented control of an induction machine (IM), a full-order flux observer has been widely used to estimate the flux. It has several critical issues, such as discrete-time domain instability, dynamics deterioration, and another instability in a low-speed sensorless flux estimation. This article addresses and analyzes these three issues. And it proposes a feedback gain design method for the full-order flux observer to solve the problems. In additional, the parameter sensitivity in the flux estimation is analyzed with a frequency response function. The experiments were conducted with an EV-traction IM. The results show the performances of the proposed feedback gain design in the high-speed operation over the conventional discrete-time domain stability limit, the dynamics improvement in mid- and high-speed region, and the stable operation in the low-speed regeneration mode.