Klaudia Juszczyk-Andraszyk

Klaudia Juszczyk-Andraszyk

Auto-generated profile, based on publicly available information

Klaudia Juszczyk-Andraszyk

Compact-Project Company, Al. Politechniki 22/24, 93-590 Lodz, Poland

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2025 in Materials
Verified
Journal Article
Open access
PDF file
Jacek SzafranJacek Szafran
Jacek Szafran
KJKlaudia Juszczyk-Andraszyk
Klaudia Juszczyk-Andraszyk
PKPaulina Kaszubska
Paulina Kaszubska
This paper presents an analysis of the effectiveness of the existing reinforcement of steel lattice tower legs made of L-sections by expanding to closely spaced built-up members. Due to the significant differences between the standard assumptions and the existing reinforcement, numerical analyses based on the component-based finite element method (CBFEM) were used to estimate the capacity of the existing structure’s tower legs. Geometrically and materially nonlinear stress analysis and linear buckling analysis were performed. The obtained results (stress distribution maps, buckling forms, and corresponding critical forces) were used to modify the geometric parameters of the section of the analyzed tower legs in order to adapt the standard formulas in the calculation procedure. In the analyzed case, distance of the connections between the branches exceeded that indicated in EN 1993-1-1:2005 for the condition concerning the possibility of ignoring the deformation susceptibility in the calculation process. However, it did not result in the separate operation of each branch of the section. Thus, in the case of the analyzed reinforcement, it is possible to neglect the form susceptibility when calculating the buckling resistance of the element. The buckling capacity of the reinforced legs of the tower and the compression capacity of the section of the analyzed structure were calculated according to the method that took into account the results of the numerical analyses. These values are about 35–48% and 30–39% higher, respectively, than the capacity of the unreinforced angle calculated according to EN 1993-1-1:2005 and EN 1993-1-8:2006 standards. Thus, it may be possible to avoid costly and labor-intensive retrofitting of the existing reinforcement to meet the standard requirements. A key issue, and one that is particularly important in light of the lack of standard guidelines aimed at designing reinforcements for telecommunications structures, seems to be the performance of full-scale experimental tests.

17 June 2025 in Archives of Civil Engineering
Verified
Journal Article
Open access
PDF file
Jacek SzafranJacek Szafran
Jacek Szafran
EKEwelina Kubacka
Ewelina Kubacka
KJKlaudia Juszczyk-Andraszyk
Klaudia Juszczyk-Andraszyk
The paper presents analyses aimed at determining how the spacing between legs of a steel lattice telecommunication tower affects displacements of its top, its natural frequency, and its self-weight. The critical characteristic of the results is that they were obtained for structures optimized with respect to the load-carrying capacity of their individual components. It was assumed that levels of effort should be kept between 85% and 95%. As far as engineering practice is concerned, the key conclusion is that a larger distance between the legs has a positive impact on the self-weight of the structure. It was demonstrated that a larger leg spacing is related to a smaller self-weight of the tower and thus a smaller quantity of material required. The proposed research and calculation method makes it possible to conclude that providing a larger distance between the legs while optimizing structural members with respect to their effort (preferably by means of an automated process) results in both higher bending stiffness and lower structure self-weight required.