Alfredo I. Hernandez

Alfredo I. Hernandez

Auto-generated profile, based on publicly available information

Alfredo I. Hernandez

Univ Rennes, Inserm, LTSI - UMR 1099, Rennes, F-35000, France

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2009 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Closed access
AHAlfredo I. Hernández
Alfredo I. Hernández
VLVirginie Lerolle
Virginie Lerolle
ADAntoine Defontaine
Antoine Defontaine
GCGuy Carrault
Guy Carrault
The role of modelling and simulation in the systemic analysis of living systems is now clearly established. Emerging disciplines, such as systems biology, and worldwide research actions, such as the Physiome Project or the Virtual Physiological Human, are based on an intensive use of modelling and simulation methodologies and tools. One of the key aspects in this context is to perform an efficient integration of various models representing different biological or physiological functions, at different resolutions, spanning through different scales. This paper presents a multiformalism modelling and simulation environment (M2SL) that has been conceived to ease model integration. A given model is represented as a set of coupled and atomic model components that may be based on different mathematical formalisms with heterogeneous structural and dynamical properties. A co-simulation approach is used to solve these hybrid systems. The pioneering model of the overall regulation of the cardiovascular system proposed by Guyton and co-workers in 1972 has been implemented under M2SL and a pulsatile ventricular model based on a time-varying elastance has been integrated in a multi-resolution approach. Simulations reproducing physiological conditions and using different coupling methods show the benefits of the proposed environment.

30 September 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DODavid Ojeda
David Ojeda
VLVirginie Lerolle
Virginie Lerolle
HRHector Romero
Hector Romero
CGClément Gallet
Clément Gallet
JBJean-Luc Bonnet
Jean-Luc Bonnet
AHAlfredo I Hernández
Alfredo I Hernández
Although the therapeutic effects of Vagus Nerve Stimulation (VNS) have been recognized in pre-clinical and pilot clinical studies, the effect of different stimulation configurations on the cardiovascular response is still an open question, especially in the case of VNS delivered synchronously with cardiac activity. In this paper, we propose a formal mathematical methodology to analyze the acute cardiac response to different VNS configurations, jointly considering the chronotropic, dromotropic and inotropic cardiac effects. A latin hypercube sampling method was chosen to design a uniform experimental plan, composed of 75 different VNS configurations, with different values for the main parameters (current amplitude, number of delivered pulses, pulse width, interpulse period and the delay between the detected cardiac event and VNS onset). These VNS configurations were applied to 6 healthy, anesthetized sheep, while acquiring the associated cardiovascular response. Unobserved VNS configurations were estimated using a Gaussian process regression (GPR) model. In order to quantitatively analyze the effect of each parameter and their combinations on the cardiac response, the Sobol sensitivity method was applied to the obtained GPR model and inter-individual sensitivity markers were estimated using a bootstrap approach. Results highlight the dominant effect of pulse current, pulse width and number of pulses, which explain respectively 49.4%, 19.7% and 6.0% of the mean global cardiovascular variability provoked by VNS. More interestingly, results also quantify the effect of the interactions between VNS parameters. In particular, the interactions between current and pulse width provoke higher cardiac effects than the changes on the number of pulses alone (between 6 and 25% of the variability). Although the sensitivity of individual VNS parameters seems similar for chronotropic, dromotropic and inotropic responses, the interacting effects of VNS parameters provoke significantly different cardiac responses, showing the feasibility of a parameter-based functional selectivity. These results are of primary importance for the optimal, subject-specific definition of VNS parameters for a given therapy and may lead to new closed-loop methods allowing for the optimal adaptation of VNS therapy through time.

1 January 1999 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
AHA.I. Hernandez
A.I. Hernandez
GCG. Carrault
G. Carrault
FMF. Mora
F. Mora
LTL. Thoraval
L. Thoraval
GPG. Passariello
G. Passariello
JSJ.M. Schleich
J.M. Schleich
Information management for critical care monitoring is still a very difficult task. Medical staff are often overwhelmed by the amount of data provided by the increased number of specific monitoring devices and instrumentation, and the lack of an effective automated system. Specifically, a basic task such as arrhythmia detection still produce an important amount of undesirable alarms, due in part to the mechanistic approach of current monitoring systems. In this work, multisensor and multisource data fusion schemes to improve atrial and ventricular activity detection in critical care environments are presented. Applications of these schemes are quantitatively evaluated and compared with current methods, showing the potential advantages of data fusion techniques for event detection in noise corrupted signals.

5 October 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HRHector Romero
Hector Romero
VLVirginie Lerolle
Virginie Lerolle
JBJean-Luc Bonnet
Jean-Luc Bonnet
CHChristine Henry
Christine Henry
PMPhilippe Mabo
Philippe Mabo
AHAlfredo I. Hernandez
Alfredo I. Hernandez
Objective: Vagus nerve stimulation (VNS) is a potential therapeutic approach in a number of clinical applications. Although VNS is commonly delivered in an open-loop approach, it is now recognized that closed-loop stimulation may be necessary to optimize the therapy. In this paper, we propose an original generic closed-loop control system that can be readily integrated into an implantable device and allows for the adaptive modulation of multiple VNS parameters. Methods: The proposed control method consists of a state transition model (STM), in which each state represents a set of VNS parameters, and a state transition algorithm that optimally selects the best STM state, minimizing the error between an observed physiological variable and a given target value. The proposed method has been integrated into a real-time adaptive VNS prototype system and has been applied here to the regulation of the instantaneous heart rate, working synchronously with cardiac cycles. A quantitative performance evaluation is performed on seven sheep by computing classical control performance indicators. A comparison with a proportional-integral (PI) controller is also performed. Results: The STM controller presents a median mean square error, overshoot, and settling time, respectively, equal to 622.21 ms 2 , 72.8%, and 7.5 beats. Conclusion: The proposed control method yields satisfactory accuracy and time response, while presenting a number of benefits over classical PI controllers. It represents a feasible approach for multiparametric VNS control on implantable devices. Significance: Closed-loop multiparametric stimulation may improve response and minimize side effects on current pathologies treated by VNS.

1 October 2011 in Progress in Biophysics and Molecular Biology
Verified
Journal Article
Closed access
AHAlfredo I. Hernández
Alfredo I. Hernández
VLVirginie Lerolle
Virginie Lerolle
DODavid Ojeda
David Ojeda
PBPierre Baconnier
Pierre Baconnier
JFJulie Fontecave-Jallon
Julie Fontecave-Jallon
STS. Randall Thomas
S. Randall Thomas