A certified reference material (CRM) for aflatoxins (AFTB1, AFTB2, AFTG1, AFTG2) and zearalenone (ZEN) in corn/peanut blended vegetable oil (GBW(E)100863) was developed to address the critical need for matrix-specific reference materials in mycotoxin analysis. The CRM was prepared by blending naturally contaminated corn and peanut oils, followed by homogenization, sterilization, and sub-packing. Homogeneity and stability studies were conducted using high-performance liquid chromatography isotope-dilution tandem mass spectrometry with a dilute-and-shoot pretreatment process. The CRM demonstrated excellent homogeneity and stability, with no significant degradation observed under either short-term (65 °C for 14 days) or long-term (25 °C for 12 months) storage conditions. An inter-laboratory comparison involving six authoritative laboratories confirmed the CRM’s accuracy and reliability, with recovery rates ranging from 90.3% to 97.3% and low relative standard deviations (RSDs) of 3.79% to 7.99%. The CRM provided a robust metrological tool for mycotoxin analysis in complex oil matrices. This study not only enriches the national reference materials library but also supports food safety initiatives by facilitating accurate and reliable mycotoxin detection in vegetable oils, thereby enhancing regulatory compliance and public health protection.
In this paper, we built a method of verifying the 4 retinols of vitamin A and 8 tocopherol isomers of vitamin E in the food industry based on RP-HPLC-PDA-FLR. The effect of laboratory light conditions on the target components was considered for the first time, and it was found that the loss rate of the target components was the smallest in the case of a white laboratory bench with red or LED light in the dark room. There was no finding of extraction recoveries of the target components with a significant difference under different saponification conditions. Meanwhile, it was found that using ethyl acetate/n-hexane mixed solvent as the extraction solvent could ensure the effective extraction of the target components. Finally, baseline separation of 12 components was achieved within 45min using the C30 column. With the help of methodological verification, we found that the recovery rate ranged from 76.45 to 93.52, and RSD was between 0.19 and 12.99; the Limit of Detection minimum value was 0.01mg/100g and the Limit of Quantitation minimum value was 0.03mg/100g. The detection method was successfully applied to the distribution detection of 4 kinds of retinols and 8 kinds of vitamin E in egg and dairy products and provided technical support for the accurate nutritional evaluation of vitamin A and vitamin E.