In the present study, wound healing ferroelectric membranes doped with zinc oxide nanoparticles were fabricated from vinylidene fluoride-tetrafluoroethylene copolymer and polyvinylpyrrolidone using the electrospinning technique. Five different ratios of vinylidene fluoride-tetrafluoroethylene to polyvinylpyrrolidone were used to control the properties of the membranes at a constant zinc oxide nanoparticle content. It was found that an increase of polyvinylpyrrolidone content leads to a decrease of the spinning solution conductivity and viscosity, causing a decrease of the average fiber diameter and reducing their strength and elongation. By means of X-ray diffraction and infrared spectroscopy, it was revealed that increased polyvinylpyrrolidone content leads to difficulty in crystallization of the vinylidene fluoride-tetrafluoroethylene copolymer in the ferroelectric β-phase in membranes. Changing the ratio of vinylidene fluoride-tetrafluoroethylene copolymer and polyvinylpyrrolidone with a constant content of zinc oxide nanoparticles is an effective approach to control the antibacterial properties of membranes towards Staphylococcus aureus. After carrying out in vivo experiments, we found that ferroelectric hybrid membranes, containing from five to ten mass percent of PVP, have the greatest wound-healing effect for the healing of purulent wounds.
Wound healing is a complex process and an ongoing challenge for modern medicine. Herein, we present the results of study of structure and properties of ferroelectric composite polymer membranes for wound healing. Membranes were fabricated by electrospinning from a solution of vinylidene fluoride/tetrafluoroethylene copolymer (VDF–TeFE) and polyvinylpyrrolidone (PVP) in dimethylformamide (DMF). The effects of the PVP content on the viscosity and conductivity of the spinning solution, DMF concentration, chemical composition, crystal structure, and conformation of VDF–TeFE macromolecules in the fabricated materials were studied. It was found that as PVP amount increased, the viscosity and conductivity of the spinning solutions decreased, resulting in thinner fibers. Using FTIR and XRD methods, it was shown that if the PVP content was lower than 50 wt %, the VDF–TeFE copolymer adopted a flat zigzag conformation (TTT conformation) and crystalline phases with ferroelectric properties were formed. Gas chromatography results indicated that an increase in the PVP concentration led to a higher residual amount of DMF in the material, causing cytotoxic effects on 3T3L1 fibroblasts. In vivo studies demonstrated that compared to classical gauze dressings impregnated with a solution of an antibacterial agent, ferroelectric composite membranes with 15 wt % PVP provided better conditions for the healing of purulent wounds.
Aim. To examine the pattern of morphological changes, RNA quality number, and gene expression in mouse tissues sampled at autopsy under controlled experimental conditions.Materials and methods. Balb/c mice were euthanized and subsequently subjected to necropsy at 0, 3, 12, 24, 48, and 72 hours of the postmortem period. During the first three hours following euthanasia, the mice were maintained at room temperature, after which they were transferred to a refrigerator (4 º С). Total RNA was extracted from tissue samples taken from the kidney, liver, and brain; the integrity of the RNA samples was assessed by capillary electrophoresis, and the RNA quality number (RQN) was calculated. The expression levels of Actb, Epas1, and Rps18 housekeeping genes were evaluated by real-time quantitative reverse transcription polymerase chain reaction (RT-qPCR) with original primers and probes using the TaqMan assay. The histologic examination was performed according to standard techniques.Results. Degradation of RNA extracted from mouse kidney tissues appeared to be greater than that of RNA taken from the liver. In the meantime, a negative linear correlation was observed between RQN and the duration of the postmortem interval for liver and kidney samples. In contrast, no significant changes in the RQN score were observed for brain RNA samples at any of the time points. The expression of the Epas1 and Rps18 genes was significantly decreased in mouse kidney and liver tissues. However, the level of Epas1 and Rps18 gene expression in the brain remained stable at all time points and did not exhibit a significant decrease at 72 hours after euthanasia. No obvious morphological changes were detected by the histologic examination, which does not exclude the presence of ultrastructural pathological changes.Conclusion. RQN in autopsy tissues serves as a crucial predictor of sample quality for molecular biology studies, including gene expression analysis.
25 June 2022 in Issues of Reconstructive and Plastic Surgery
The paper contains the results of an experimental study of the effect of ferroelectric composite polymer membranes on the healing process of purulent wounds. The membranes were formed by electrospinning based on vinylidene fluoride-terafluoroethylene copolymer, polyvinylpyrrolidone K17 (PVP) polymer, zinc oxide nanoparticles (ZnO). Five spinning solutions with different contents of PVP were prepared: 0, 5, 10, 20 and 40 mass %.The effect of the membranes was evaluated depending on the content of PVP. The conductivity and viscosity ofthe spinning solutions were determined. The structure of the formed membranes was studied. The diameter of the fibers forming the membranes was determined by scanning electron microscopy. The antibacterial activity of the membranes was evaluated. The ability of the developed membranes to heal a purulent wound was studied in experiments on laboratory animals.
Herein, we report results of the study of the composite ferroelectric scaffolds based on vinylidene fluoride-tetrafluoroethylene copolymer (VDF-TeFE) and polyvinylpyrrolidone (PVP) produced by electrospinning and their application as a wound-healing material. The physicochemical properties of ferroelectric composite polymer scaffolds depending on the content of PVP (in the range from 0 to 50 wt %) including morphology, composition and crystalline structure were studied. The cytotoxicity of materials and the proliferative activity of cells during their cultivation on the surface of formed scaffolds are reported. It has been found that the optimal PVP content in the VDF-TeFE composite scaffolds is 15 wt%. On a model of a full-thickness contaminated wound in vivo, it was shown that piezoelectric scaffolds based on VDF-TeFE copolymer containing 15 wt% PVP provide better wound healing results in comparison with standard gauze dressings impregnated with a solution of an antibacterial agent.
23 March 2022 in Journal of Experimental and Clinical Surgery
Introduction. Enterostomy remains a relevant option of staged treatment of small intestine diseases in children. T-anastomosis with stoma (Bishop-Koop) and double-barreled enterostomy with compression anastomosis (Mikulicz) are among the most widely accepted ones. Disadvantages of compression anastomosis can be eliminated by using a NiTi-clip with shape memory. The aim of the study was to perform an experimental study to detect effectiveness and advantages of NiTi-clip application in formation of a compression anastomosis in a double-barreled enterostomy compared with manual T-anastomosis. Methods. The study included 24 rabbits of the "Serebristyi" breed, aged 2.5-3 months, weighed 2790-3100 g; they were divided into two equal groups. Autopsy was performed in 10, 14, 21 days with pneumopression and histological examination. Differences were considered statistically significant at p-value 0.05. Results. The duration of the Mikulicz operation (group A) was significantly shorter than that of Bishop-Koop`s (group B) (p = 0.000). Significant differences in weight were found in 14. 21 days, with a predominance in group A (p = 0.029). Complications included wound suppuration, eventration, peritonitis, evagination, dermatitis, and anastomotic leakage. In 10 days, compression anastomosis had a lower anastamotic pressure, but in 21 days, it was more stabile than in manual anastomosis (p = 0.019). In 14 days, inflammatory changes in the mucosa with fibrosis in the muscle layers and lesions were detected in the area of manual anastomosis, they were accompanied by inflammation around sutures. In 21 days, fibrotic changes spread in all layers. Proliferation prevailed over inflammation in the area of the compression anastomosis. Conclusions. Double-barreled stoma formation with NiTi-clip application took less time than T-anastomosis. Animals with a double-barreled stoma and compression anastomosis had a larger weight gain. Compression anastomosis with NiTi-clip in the stoma was stabile than manual anastomosis. With compression anastomosis, layer-by-layer regeneration from serous to mucous membrane occurs, healing occurred faster, with a predominance of proliferation processes, the risk of stenosis decreased. The use of NiTi-clip in the surgical treatment of children with double-barreled enterostomy can be recommended for practical use.