M. Keith Matzen

M. Keith Matzen

Auto-generated profile, based on publicly available information

M. Keith Matzen

Sandia National Laboratories 1 , P.O. Box 5800, Albuquerque, New Mexico 87185, USA

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2023 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
DRD. E. Ruiz
D. E. Ruiz
PSP. F. Schmit
P. F. Schmit
DYD. A. Yager-Elorriaga
D. A. Yager-Elorriaga
MGM. R. Gomez
M. R. Gomez
MWM. R. Weis
M. R. Weis
MMM. K. Matzen
M. K. Matzen
Magnetized liner inertial fusion (MagLIF) is a magneto-inertial-fusion (MIF) concept, which is presently being studied on the Z pulsed power facility. The MagLIF platform has achieved interesting plasma conditions at stagnation and produced significant fusion yields in the laboratory. Given the relative success of MagLIF, there is a strong interest to scale the platform to higher peak currents. However, scaling MagLIF is not entirely straightforward due to the large dimensionality of the experimental input parameter space and the numerous physical processes involved in MIF implosions. In this work, we propose a novel method to scale MagLIF loads to higher currents. Our method is based on similarity (or similitude) scaling and attempts to preserve much of the physics regimes already known or being studied on today's Z pulsed-power driver. By avoiding significant deviations into unexplored and/or less well-understood regimes, the risk of unexpected outcomes on future scaled-up experiments is reduced. Using arguments based on similarity scaling, we derive the scaling rules for the experimental input parameters characterizing a MagLIF load (as functions of the characteristic current driving the implosion). We then test the estimated scaling laws for various metrics measuring performance against results of 2D radiation–magneto-hydrodynamic hydra simulations. Agreement is found between the scaling theory and the simulation results.

1 December 2000 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
PDF file
RSR B Spielman
R B Spielman
CDC Deeney
C Deeney
MDM R Douglas
M R Douglas
GCG A Chandler
G A Chandler
MCM E Cuneo
M E Cuneo
JHJ H Hammer
J H Hammer

1 January 1996 in Progress in Nuclear Energy
Verified
Journal Article
Closed access
JQJ.P. Quintenz
J.P. Quintenz
DBD.D. Bloomquist
D.D. Bloomquist
RLR.J. Leeper
R.J. Leeper
TMTom Mehlhorn
Tom Mehlhorn
COC.L. Olson
C.L. Olson
DCD.L. Cook
D.L. Cook

1 March 2023 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
DRD. E. Ruiz
D. E. Ruiz
PSP. F. Schmit
P. F. Schmit
MWM. R. Weis
M. R. Weis
KPK. J. Peterson
K. J. Peterson
MMM. K. Matzen
M. K. Matzen
Magnetized liner inertial fusion (MagLIF) is a z-pinch magneto-inertial-fusion concept studied at the Z Pulsed Power Facility of Sandia National Laboratories. Two important metrics characterizing current delivery to a z-pinch load are the peak current and the current-rise time, which is roughly the time interval to reach the peak current. It is known that, when driving a z-pinch load with a longer current-rise time, the performance of the z-pinch decreases. However, a theory to understand and quantify this effect is still lacking. In this paper, we utilize a framework based on similarity scaling to analytically investigate the variations in the performance of MagLIF loads when varying the current-rise time, or equivalently, the implosion timescale. To maintain similarity between the implosions, we provide scaling prescriptions of experimental input parameters defining a MagLIF load and derive the expected scaling laws for stagnation conditions and for various performance metrics. We compare predictions of the theory to 2D numerical simulations using the radiation, magneto-hydrodynamic code hydra. For several metrics, we find acceptable agreement between the theory and simulations. Our results show that the voltage φload near the MagLIF load follows a weak scaling law φload∝tφ−0.12 with respect to the characteristic timescale tφ of the voltage source, instead of the ideal φload∝tφ−1 scaling. This occurs because the imploding height of the MagLIF load must increase to preserve end losses. As a consequence of the longer imploding liners, the required total laser preheat energy and delivered electric energy increase. Overall, this study helps understand the trade-offs of the MagLIF design space when considering future pulsed-power generators with shorter and longer current-rise times.

24 July 2023 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
CMClayton E. Myers
Clayton E. Myers
DBDavid E. Bliss
David E. Bliss
PCPeter M. Celliers
Peter M. Celliers
PDPhilip S. Datte
Philip S. Datte
MHMark H. Hess
Mark H. Hess
AYAdam J. York
Adam J. York
Pulsed power generators create high-energy-density conditions by rapidly delivering an immense pulse of electrical current to a compact imploding load. Accurately measuring the shape and amplitude of this load current pulse is essential to understanding the behavior of all pulsed power experiments. At the Z Pulsed Power Facility, the closest-in load current measurements are provided by velocimetry techniques such as VISAR (velocity interferometer system for any reflector) and PDV (photonic Doppler velocimetry). Here, fiber-coupled interferometers measure the velocity history of an exploding metallic flyer plate that is embedded in the vertical walls of the current return can. The flyer plate is driven outward by the magnetic pressure from the load current such that magnetohydrodynamic modeling can be used to determine the load current waveform from the measured velocity history. In this paper, we present the first load current velocimetry measurements to be made from the horizontal top flyer plate that carries current radially inward from the return can to the load. These spatially resolved measurements, which span R=5–9  mm, are enabled by a transformative new velocimetry diagnostic—a line-imaging velocity interferometer called Z Line VISAR (ZLV)—whose optical performance overcomes the measurement challenges presented by the steep velocity gradients encountered on the top flyer plate. To validate ZLV’s capabilities, a 14-MA, 100-ns experiment was conducted to losslessly couple current up the return can and radially inward across the top flyer plate. Comparisons between the ZLV data obtained from this experiment and two-dimensional magnetohydrodynamic simulations driven with the current measured on the return can indicate that the current delivery across the top flyer plate is indeed lossless to within the few-percent uncertainty of the ZLV data. Given that the current coupling is lossless, the experimental results are used to demonstrate that one-dimensional current unfold techniques can be applied to generate a radially resolved load current map from the ZLV velocity data. This analysis provides a template for how to use the ZLV diagnostic to determine the efficacy of current delivery in future experiments where losses may occur in close proximity to the load.

24 September 2025 in Journal of Applied Physics
Verified
Journal Article
Open access
EJE. R. Jans
E. R. Jans
SKS. P. Kearney
S. P. Kearney
ASA. M. Steinberg
A. M. Steinberg
MMM. K. Matzen
M. K. Matzen
NBNathan Brown
Nathan Brown
Single-shot fs laser-induced breakdown spectroscopy (LIBS) has been used to interrogate low-density gases of H2, CH4, CO2, and H2O ranging from 0.5×1015 to 9.1×1015 cm−3 (15–275 mTorr). Strong spectral signatures were observed above the noise baseline for each test gas at all densities considered. Unique molecular signatures were observed for both CH4 and CO2 along with atomic features for each gas. The LIBS intensity response with respect to density was determined for each species using Voigt lineshape fitting or numerical integration. Finally, the collection and analysis of LIBS spectra of composite mixtures of CH4–CO2 and CH4–H2 demonstrates that the extraction of individual densities from gas mixtures is feasible at low densities.