Jing Lyu

Jing Lyu

Auto-generated profile, based on publicly available information

Jing Lyu

Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JLJing Lyu
Jing Lyu
Xin ZhangXin Zhang
Xin Zhang
XCXu Cai
Xu Cai
MMMarta Molinas
Marta Molinas
The small-signal impedance modeling of a modular multilevel converter (MMC) is the key for analyzing resonance and stability of MMC-based power electronic systems. The MMC is a power converter with a multifrequency response due to its significant steady-state harmonic components in the arm currents and capacitor voltages. These internal harmonic dynamics may have great influence on the terminal characteristics of the MMC, which, therefore, are essential to be considered in the MMC impedance modeling. In this paper, the harmonic state-space (HSS) modeling approach is first introduced to characterize the multiharmonic coupling behavior of the MMC. On this basis, the small-signal impedance models of the MMC are then developed based on the proposed HSS model of the MMC, which are able to include all the internal harmonics within the MMC, leading to accurate impedance models. Besides, different control schemes for the MMC, such as open-loop control, ac voltage closed-loop control, and circulating current closed-loop control, have also been considered during the modeling process, which further reveals the impact of the MMC internal dynamics and control dynamics on the MMC impedance. Furthermore, an impedance-based stability analysis of the MMC-high-voltage direct current connected wind farm has been carried out to show how the HSS-based MMC impedance model can be used in practical system analysis. Finally, the proposed impedance models are validated by both simulation and experimental measurements.

4 October 2017 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
JLJing Lyu
Jing Lyu
XCXu Cai
Xu Cai
MMMarta Molinas
Marta Molinas
A subsynchronous oscillation (SSO) phenomenon has been observed in a modular multilevel converter-based high-voltage DC (MMC-HVDC) transmission system for wind farm integration in the real world, which is independent of the type of wind turbine generator. This kind of oscillation appears different from those in DFIG-based wind farm with series-compensation line or wind farm integration through two-level VSC-HVDC transmission system, because the internal dynamics of the MMC may have significant impact on the oscillation. By far, however, very few papers have reported it. In this paper, the generation mechanism of the SSO phenomenon in an MMC-HVDC transmission system for wind farm integration is revealed from an impedance point of view. The harmonic state-space (HSS) modeling method is applied to model the multi-frequency behavior of the MMC, based on which, the ac-side small-signal impedance of the MMC is analytically derived according to harmonic linearization theory. As a general rule, the controller parameters of the wind power inverter and the HVDC converter are designed separately, to meet the performance requirements of the single converter under ideal conditions, but this practice does not guarantee the stability of the interconnected system. Therefore, an optimal design method for controller parameters is proposed in this paper in order to guarantee the small-signal stability of the interconnected system from a system point of view. Finally, time-domain simulations validate the effectiveness of the theoretical analysis and the proposed optimal design method.

21 April 2021 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
TXTao Xue
Tao Xue
JLJing Lyu
Jing Lyu
HWHan Wang
Han Wang
XCXu Cai
Xu Cai
Impedance modeling of a permanent magnet synchronous generator (PMSG)-based wind energy conversion system (WECS) usually ignores the machine-side dynamics, instead, the machine-side system is simplified as a constant power source, while merely keeping the detailed grid-side converter model. This simplification is mainly based upon the intuition that the dc-bus capacitor is large enough so that the machine- and grid-side dynamics can be decoupled. However, the simplification probably does not hold in practice since there is always a tendency to minimize the capacitor size to achieve a smaller package for installation. Therefore, the machine-side system should not be ignored, otherwise maybe leading to error for stability analysis. To address this issue, this paper developed a complete ac-side impedance model of the PMSG-based WECS. Then, impact factors about the coupling characteristics between machine- and grid-side systems of the PMSG-based WECS are discussed. Finally, a case study of sub/super synchronous oscillation is carried out on a practical offshore wind farm integrated with a modular multilevel converter based high-voltage dc (MMC-HVDC) transmission system in China. The results show that ignoring the machine-side system would lead to an optimistic stability judgement, which confirms the necessity of the complete model of PMSG-based WECS. Furthermore, the system can be stabilized by either changing the couplings between machine- and grid-side systems of PMSG-based WECS or implementing active damping in the wind farm side MMC.

9 April 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CZChen Zhang
Chen Zhang
MMMarta Molinas
Marta Molinas
ARAtle Rygg
Atle Rygg
JLJing Lyu
Jing Lyu
XCXu Cai
Xu Cai
Impedance modeling and stability analysis of a grid-voltage source converters (VSC) system under symmetric ac grids have been extensively discussed in the literature, where the dq domain impedances are usually adopted. As for asymmetric ac grids, impedance modeling is no longer straightforward in the dq domain due to the presence of negative sequence components, where the linearization will result in a linear-time-periodically-varying system, making the frequency-domain analysis intractable. One way to address this issue would be the harmonic-transfer-function (HTF) approach. Although this method is conceptually clear, its application to the stability analysis of an unbalanced grid-VSC system is still challenging and an effective model is missing here, therefore this paper aims to bridge this gap. First, the sequence impedances of an unbalanced grid-VSC system is modeled in the HTF framework. Then the HTFs are truncated into four-by-four matrices by exploiting the property of frequency couplings. Based on this, the equivalent source and load model for Nyquist-based analysis are established, and they are thoroughly verified by impedance measurements as well as the accuracy on stability analysis. Finally, several stability concerns of the unbalanced grid-VSC system, as well as the feasibility of symmetric models for asymmetric ac grid stability analysis are discussed and clarified.

16 March 2020 in IEEE Access
Verified
Journal Article
Open access
HZHaoxiang Zong
Haoxiang Zong
CZChen Zhang
Chen Zhang
JLJing Lyu
Jing Lyu
XCXu Cai
Xu Cai
MMMarta Molinas
Marta Molinas
FRFangquan Rao
Fangquan Rao
Recently, small-signal stability of the modular multilevel converter (MMC) based high-voltage direct current (HVDC) transmission for wind farm integration has attracted great attentions. The impedance-based frequency-domain method is an effective tool for such studies, in which the accuracy of the impedance model is of significant importance. Currently, the decoupled single-input single-output (SISO) sequence impedance of the MMC-HVDC system with wind farm is commonly used due to the simplicity in stability analysis. However, since both the MMC and wind farm exhibit frequency coupling behaviors, the decoupled SISO sequence impedance model may lead to inaccurate stability conclusion under certain conditions. In order to improve the model accuracy, based on the harmonic state-space (HSS) modeling approach, this paper proposes a generalized multi-input multi-output (MIMO) sequence impedance model of the MMC-wind farm system. The proposed MIMO impedance model can effectively capture the frequency couplings in the interconnected system, based on which the coupling mechanism of multi-frequency components within the MMC is then revealed. To facilitate the interconnection analysis, the model truncation criteria is proposed and validated by comparing the accuracy of the MIMO model with different truncated dimensions. In addition, this paper considers the internal impedance network of the wind farm when developing the aggregated wind farm impedance model for interaction stability analysis. Finally, the proposed MIMO sequence impedance model is applied to accurately predict the instability of the MMC-HVDC connected wind farm system.

17 November 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
JLJing Lyu
Jing Lyu
YRYiming Rao
Yiming Rao
ZWZhong Wang
Zhong Wang
JDJinshui Dai
Jinshui Dai
XCXu Cai
Xu Cai
This paper presents a data-driven methodology for impedance identification and online stability assessment of wind farm integration with modular multilevel converter-based high-volage dc (MMC-HVDC) transmission system, which is applicable for black/grey-box models in practice. In order to improve the impedance identification accuracy, a neural network (NN) optimization method based on the evaluation coefficient is proposed to train the wideband impedance identification models of wind turbine generator (WTG) and MMC. On this basis, the physics-informed data-driven method for online wideband impedance identification of a wind farm is then proposed by combining the NN-based impedance identification models of WTGs and physical topology information of wind farm, which has the advantages of low data requirements and better interpretability. Based on the identified impedances, the oscillatory stability of the wind farm-MMC interconnected system can be evaluated online using generalized Nyquist criterion. Finally, case studies are carried out to validate the accuracy of the proposed impedance identification and online stability assessment methods.