Atle Rygg

Atle Rygg

Auto-generated profile, based on publicly available information

Atle Rygg

Department of Engineering Cybernetics, Norwegian University of Science and Technology, Trondheim, Norway

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2016 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ARAtle Rygg
Atle Rygg
MMMarta Molinas
Marta Molinas
CZChen Zhang
Chen Zhang
XCXu Cai
Xu Cai
Representation of ac power systems by frequency-dependent impedance equivalents is an emerging technique in the dynamic analysis of power systems including power electronic converters. The technique has been applied for decades in dc-power systems, and it was recently adopted to map the impedances in ac systems. Most of the work on ac systems can be categorized into two approaches. One is the analysis of the system in the dq domain, whereas the other applies harmonic linearization in the phase domain through symmetric components. Impedance models based on analytical calculations, numerical simulation, and experimental studies have been previously developed and verified in both domains independently. The authors of previous studies discuss the advantages and disadvantages of each domain separately, but neither a rigorous comparison nor an attempt to bridge them has been conducted. This paper attempts to close this gap by deriving the mathematical formulation that shows the equivalence between the dq-domain and the sequence-domain impedances. A modified form of the sequence-domain impedance matrix is proposed, and with this definition the stability estimates obtained with the generalized Nyquist criterion become equivalent in both domains. The second contribution of this paper is the definition of a mirror frequency decoupled (MFD) system. The analysis of MFD systems is less complex than that of non-MFD systems because the positive and negative sequences are decoupled. This paper shows that if a system is incorrectly assumed to be MFD, this will lead to an erroneous or ambiguous estimation of the equivalent impedance.

2 November 2017 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
CZChen Zhang
Chen Zhang
XCXu Cai
Xu Cai
ARAtle Rygg
Atle Rygg
MMMarta Molinas
Marta Molinas
This paper presents a generalized method for converting multi-input and multi-output (MIMO) dq impedance model of a grid-tied voltage source converter system into its sequence domain single-input and single-output (SISO) equivalents. As a result, two types of SISO impedance models were derived, one of which was derived from relatively strong and dq symmetric grid assumption (reduced SISO model) and the other was based on closed-loop equivalent (accurate SISO model). It was proven that the accurate SISO model has the same marginal stability condition as the MIMO model. Accuracy of these models is assessed with respect to the measured impedances in PSCAD/EMTDC simulations, their effects on stability are analyzed as well. Findings show that the accurate SISO model presents identical stability conclusions as the MIMO model. However, the reduced SISO model may lead to inaccurate results if the system is highly dq asymmetric, e.g., VSC with fast phase-locked loop or an actively controlled grid.

3 May 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
CZChen Zhang
Chen Zhang
MMMarta Molinas
Marta Molinas
ARAtle Rygg
Atle Rygg
XCXu Cai
Xu Cai
Impedance is an intuitive and effective way for dynamical representation of power electronics devices (e.g. VSCs). One of its strengths towards others is the natural association with circuits. However, impedances of VSCs are locally evaluated via linearization, a process dependent on the angle of the reference frame, thus the reference frame transformation (i.e. rotation) is required before connecting them in circuits for the purpose of network analysis. Although this issue was properly treated in the state-space modeling, a counterpart for the impedance-based analysis, particularly the stability impacts of this rotation have not been thoroughly discussed and worth being clarified. On the other hand, there are fundamental differences in applying the impedance-based stability criteria of a single-VSC system to an interconnected one. Several restrictions as revealed (e.g. sensitivity to partition points of the Nyquist-based analysis), if not properly considered, may lead to inaccurate stability assessments. In this respect, a clarification of three commonly employed impedancebased stability criteria is achieved. At last, the capability of the Nyquist-based analysis in identifying the system’s weak point and in facilitating better network design and planning is presented. All the models and analyses are verified by frequency-scanning and time-domain simulations in PSCAD/EMTDC.

25 August 2017 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ARAtle Rygg
Atle Rygg
MMMarta Molinas
Marta Molinas
CZChen Zhang
Chen Zhang
XCXu Cai
Xu Cai
Small-signal analysis of power electronic converters and systems is often carried out by impedance-based methods. At the core of these methods lies the impedance modeling, which can either be obtained through analytical calculations, simulations, or measurements. The impedance models can be obtained into two main domains: the dq-domain and the sequence domain. In the dq-domain, the impedance model is a 2×2 matrix, while in the sequence domain, it is composed by the positive and negative sequence impedance. Recently, a third domain called the modified sequence domain was defined as an extension to the sequence domain, but also with clear similarities to the dq-domain. The objective of this paper is to unambiguously relate to each other the impedances in these three domains, and to show how this equivalence translates into their respective stability assessments. It is also proven that the sequence domain impedance has the same marginal stability condition as the dq-domain impedance matrix. The three-phase voltage source converter is used as an example converter in this paper, as its impedance model in all three domains is well established and reported by previous research. The results in this paper show that the modified sequence domain model can be derived from the dq-domain model (and vice versa), and that the stability analysis will be identical in these two domains. It is also shown how the original sequence domain model can be derived from the two other models through a model reduction. However, a small discrepancy between the two Nyquist plots is observed in the presence of components such as phase-locked loop or dc-link control.

20 July 2017 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ARAtle Rygg
Atle Rygg
MMMarta Molinas
Marta Molinas
In this paper, a new method for power system stability analysis is introduced. The method is based on injection of a small voltage or current in an arbitrary point of a power system. The apparent impedance is then defined as the ratio between the voltage and current at the injection point. It is shown that the apparent impedance can be used to estimate the eigenvalues of the system that are observable from the injection point. The eigenvalues are obtained by applying system identification techniques to the measured set of apparent impedances. The method is similar to the well-established impedance-based stability analysis based on source and load impedance models. However, while the source/load impedance ratio is viewed as the minor-loop gain, the apparent impedance can be viewed as a closed-loop transfer function. It can also be expressed as the parallel connection of the source and load impedance. It is shown, in this paper, how the system eigenvalues can be extracted based on a set of apparent impedance values. The apparent impedance holds, therefore, complementary information compared with the existing impedance-based stability analysis. The method can also be used as a tool to validate analytically derived state-space models. In this paper, the method is presented as a simulation tool, while further work will extend it to include experimental setups. Two case studies are presented to illustrate the method: 1) a dc case with a buck converter feeding a constant power load and 2) a three-phase grid-connected voltage source converter with a current controller and a phase lock loop. The estimated (apparent) eigenvalues of the studied systems are equal to those obtained from the analytic state-space model.

9 April 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CZChen Zhang
Chen Zhang
MMMarta Molinas
Marta Molinas
ARAtle Rygg
Atle Rygg
JLJing Lyu
Jing Lyu
XCXu Cai
Xu Cai
Impedance modeling and stability analysis of a grid-voltage source converters (VSC) system under symmetric ac grids have been extensively discussed in the literature, where the dq domain impedances are usually adopted. As for asymmetric ac grids, impedance modeling is no longer straightforward in the dq domain due to the presence of negative sequence components, where the linearization will result in a linear-time-periodically-varying system, making the frequency-domain analysis intractable. One way to address this issue would be the harmonic-transfer-function (HTF) approach. Although this method is conceptually clear, its application to the stability analysis of an unbalanced grid-VSC system is still challenging and an effective model is missing here, therefore this paper aims to bridge this gap. First, the sequence impedances of an unbalanced grid-VSC system is modeled in the HTF framework. Then the HTFs are truncated into four-by-four matrices by exploiting the property of frequency couplings. Based on this, the equivalent source and load model for Nyquist-based analysis are established, and they are thoroughly verified by impedance measurements as well as the accuracy on stability analysis. Finally, several stability concerns of the unbalanced grid-VSC system, as well as the feasibility of symmetric models for asymmetric ac grid stability analysis are discussed and clarified.