Miklos Marosfoi

Miklos Marosfoi

Auto-generated profile, based on publicly available information

Miklos Marosfoi

National Institute of Neurosciences, Budapest, Hungary

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2013 in Radiology
Verified
Journal Article
Closed access
TBTibor Becske
Tibor Becske
DKDavid F. Kallmes
David F. Kallmes
ISIsil Saatci
Isil Saatci
CMCameron G. McDougall
Cameron G. McDougall
ISIstván Szikora
István Szikora
PNPeter K. Nelson
Peter K. Nelson
To evaluate the safety and effectiveness of the Pipeline Embolization Device (PED; ev3/Covidien, Irvine, Calif) in the treatment of complex intracranial aneurysms. The Pipeline for Uncoilable or Failed Aneurysms is a multicenter, prospective, interventional, single-arm trial of PED for the treatment of uncoilable or failed aneurysms of the internal carotid artery. Institutional review board approval of the HIPAA-compliant study protocol was obtained from each center. After providing informed consent, 108 patients with recently unruptured large and giant wide-necked aneurysms were enrolled in the study. The primary effectiveness endpoint was angiographic evaluation that demonstrated complete aneurysm occlusion and absence of major stenosis at 180 days. The primary safety endpoint was occurrence of major ipsilateral stroke or neurologic death at 180 days. PED placement was technically successful in 107 of 108 patients (99.1%). Mean aneurysm size was 18.2 mm; 22 aneurysms (20.4%) were giant (>25 mm). Of the 106 aneurysms, 78 met the study's primary effectiveness endpoint (73.6%; 95% posterior probability interval: 64.4%-81.0%). Six of the 107 patients in the safety cohort experienced a major ipsilateral stroke or neurologic death (5.6%; 95% posterior probability interval: 2.6%-11.7%). PED offers a reasonably safe and effective treatment of large or giant intracranial internal carotid artery aneurysms, demonstrated by high rates of complete aneurysm occlusion and low rates of adverse neurologic events; even in aneurysms failing previous alternative treatments.

11 February 2010 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
ISI. Szikora
I. Szikora
ZBZ. Berentei
Z. Berentei
ZKZsolt Kulcsar
Zsolt Kulcsar
MMM. Marosfoi
M. Marosfoi
ZVZ.S. Vajda
Z.S. Vajda
PNP.K. Nelson
P.K. Nelson
BACKGROUND AND PURPOSE: Aneurysm treatment by intrasaccular packing has been associated with a relatively high rate of recurrence. The use of mesh tubes has recently gained traction as an alternative therapy. This article summarizes the midterm results of using an endoluminal sleeve, the PED, in the treatment of aneurysms. MATERIALS AND METHODS: A total of 19 wide-neck aneurysms were treated in 18 patients: 10 by implantation of PEDs alone and 9 by a combination of PED and coils. Angiographic and clinical results were recorded immediately and at 6 months following treatment. RESULTS: Immediate angiographic occlusion was achieved in 4 and flow reduction, in another 15 aneurysms. Angiography at 6 months demonstrated complete occlusion in 17 and partial filling in 1 of 18 patients. There was no difference between coil-packed and unpacked aneurysms. Of 28 side branches covered by ≥1 device, the ophthalmic artery was absent immediately in 1 and at 6 months in another 2 cases. One patient experienced abrupt in-stent thrombosis resulting in a transient neurologic deficit, and 1 patient died due to rupture of a coexisting aneurysm. All giant aneurysms treated with PED alone were demonstrated by follow-up cross-sectional imaging to have involuted by 6 months. CONCLUSIONS: Treatment of large, wide-neck, or otherwise untreatable aneurysms with functional reconstruction of the parent artery may be achieved with relative safety using dedicated flow-modifying devices with or without adjunctive use of intrasaccular coil packing.

10 February 2011 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
ZKZsolt Kulcsar
Zsolt Kulcsar
ÁUÁ. Ugron
Á. Ugron
MMM. Marosfői
M. Marosfői
ZBZ. Berentei
Z. Berentei
GPG. Paál
G. Paál
ISI. Szikora
I. Szikora
BACKGROUND AND PURPOSE: Cerebral aneurysms are preferentially located at arterial curvatures and bifurcations that are exposed to major hemodynamic forces, increasingly implicated in the life cycle of aneurysms. By observing the natural history of aneurysm formation from its preaneurysm state, we aimed to examine the hemodynamic microenvironment related to aneurysm initiation at certain arterial segments later developing an aneurysm. MATERIALS AND METHODS: The 3 patients included in the study underwent cerebral angiography with 3D reconstruction before a true aneurysm developed. The arterial geometries obtained from the 3D-DSA models were used for flow simulation by using finite-volume modeling. The WSS and SWSSG at the site of the future aneurysm and the flow characteristics of the developed aneurysms were analyzed. RESULTS: The analyzed regions of interest demonstrated significantly increased WSS, accompanied by an increased positive SWSSG in the adjacent proximal region. The WSS reached values of >5 times the temporal average values of the parent vessel, whereas the SWSSG approximated or exceeded peaks of 40 Pa/mm in all 3 cases. All patients developed an aneurysm within 2 years, 1 of which ruptured. CONCLUSIONS: The results of this hemodynamic study, in accordance with the clinical follow-up, suggest that the combination of high WSS and high positive SWSSG focused on a small segment of the arterial wall may have a role in the initiation process of aneurysm formation.

1 July 2017 in Journal of Neurosurgery
Verified
Journal Article
Closed access
TBTibor Becske
Tibor Becske
MPMatthew B. Potts
Matthew B. Potts
MSMaksim Shapiro
Maksim Shapiro
DKDavid F. Kallmes
David F. Kallmes
WBWaleed Brinjikji
Waleed Brinjikji
PNPeter K. Nelson
Peter K. Nelson
OBJECTIVE: The long-term effectiveness of endovascular treatment of large and giant wide-neck aneurysms using traditional endovascular techniques has been disappointing, with high recanalization and re-treatment rates. Flow diversion with the Pipeline Embolization Device (PED) has been recently used as a stand-alone therapy for complex aneurysms, showing significant improvement in effectiveness while demonstrating a similar safety profile to stent-supported coil treatment. However, relatively little is known about its long-term safety and effectiveness. Here the authors report on the 3-year safety and effectiveness of flow diversion with the PED in a prospective cohort of patients with large and giant internal carotid artery aneurysms enrolled in the Pipeline for Uncoilable or Failed Aneurysms (PUFS) trial.METHODS: The PUFS trial is a prospective study of 107 patients with 109 aneurysms treated with the PED. Primary effectiveness and safety end points were demonstrated based on independently monitored 180-day clinical and angiographic data. Patients were enrolled in a long-term follow-up protocol including 1-, 3-, and 5-year clinical and imaging follow-up. In this paper, the authors report the midstudy (3-year) effectiveness and safety data.RESULTS: At 3 years posttreatment, 74 subjects with 76 aneurysms underwent catheter angiography as required per protocol. Overall, complete angiographic aneurysm occlusion was observed in 71 of these 76 aneurysms (93.4% cure rate). Five aneurysms were re-treated, using either coils or additional PEDs, for failure to occlude, and 3 of these 5 were cured by the 3-year follow-up. Angiographic cure with one or two treatments of Pipeline embolization alone was therefore achieved in 92.1%. No recanalization of a previously completely occluded aneurysm was noted on the 3-year angiograms. There were 3 (2.6%) delayed device- or aneurysm-related serious adverse events, none of which led to permanent neurological sequelae. No major or minor late-onset hemorrhagic or ischemic cerebrovascular events or neurological deaths were observed in the 6-month through 3-year posttreatment period. Among 103 surviving patients, 85 underwent functional outcome assessment in which modified Rankin Scale scores of 0–1 were demonstrated in 80 subjects.CONCLUSIONS: Pipeline embolization is safe and effective in the treatment of complex large and giant aneurysms of the intracranial internal carotid artery. Unlike more traditional endovascular treatments, flow diversion results in progressive vascular remodeling that leads to complete aneurysm obliteration over longer-term follow-up without delayed aneurysm recanalization and/or growth.Clinical trial registration no.: NCT00777088 (clinicaltrials.gov)

14 March 2013 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
ISI. Szikora
I. Szikora
MMM. Marosfői
M. Marosfői
BSB. Salomváry
B. Salomváry
ZBZ. Berentei
Z. Berentei
IGI. Gubucz
I. Gubucz
BACKGROUND AND PURPOSE: Alleviation of aneurysm induced mass effect has been difficult with both conventional endovascular and surgical techniques. Our aim was to study the efficacy of endovascular flow modification on aneurysm-induced mass effect and compression syndrome, as demonstrated by cross-sectional imaging studies and clinical follow-up. MATERIALS AND METHODS: Thirty aneurysms larger than 10 mm were treated by flow diversion alone and previously had undergone pre- and posttreatment cross-sectional imaging. Pretreatment MR imaging or contrast CT, follow-up angiography at 6 months, and follow-up MR imaging studies between 6 and 18 months were retrospectively analyzed. The neurologic and neuro-ophthalmologic statuses of all patients were recorded before treatment and at the time of follow-up cross-sectional imaging. RESULTS: At 6 months, 28 aneurysms were completely occluded, 1 had a neck remnant, and 1 had residual filling on angiography. Between 6 and 18 months, 3 aneurysms decreased in size and 27 completely collapsed as demonstrated on MR imaging. Before treatment, 6 patients had vision loss, 10 had double vision due to a third or sixth nerve palsy or both, and 1 had hemiparesis due to brain stem compression. On MR imaging follow-up, vision loss had either improved or resolved in all except 1 patient, double vision had resolved completely (7/10) or partially (3/10), and the patient with brain stem compression became asymptomatic. There was no bleeding observed in this series. One parent artery thrombosis resulted in a major infarct. CONCLUSIONS: Endovascular flow diversion is a highly effective technique for resolving radiologic mass effect and clinical compression syndromes.

31 July 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
GUGiovanni J. Ughi
Giovanni J. Ughi
MMMiklos G. Marosfoi
Miklos G. Marosfoi
RKRobert M. King
Robert M. King
JCJildaz Caroff
Jildaz Caroff
LPLindsy M. Peterson
Lindsy M. Peterson
APAjit S. Puri
Ajit S. Puri
Intravascular imaging has emerged as a valuable tool for the treatment of coronary and peripheral artery disease; however, no solution is available for safe and reliable use in the tortuous vascular anatomy of the brain. Endovascular treatment of stroke is delivered under image guidance with insufficient resolution to adequately assess underlying arterial pathology and therapeutic devices. High-resolution imaging, enabling surgeons to visualize cerebral arteries' microstructure and micron-level features of neurovascular devices, would have a profound impact in the research, diagnosis, and treatment of cerebrovascular diseases. Here, we present a neurovascular high-frequency optical coherence tomography (HF-OCT) system, including an imaging console and an endoscopic probe designed to rapidly acquire volumetric microscopy data at a resolution approaching 10 microns in tortuous cerebrovascular anatomies. Using a combination of in vitro, ex vivo, and in vivo models, the feasibility of HF-OCT for cerebrovascular imaging was demonstrated.