Istvan Szikora

Istvan Szikora

Auto-generated profile, based on publicly available information

Istvan Szikora

Neurointerventions, National Institute of Neurosciences, Budapest, Hungary

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2013 in Radiology
Verified
Journal Article
Closed access
TBTibor Becske
Tibor Becske
DKDavid F. Kallmes
David F. Kallmes
ISIsil Saatci
Isil Saatci
CMCameron G. McDougall
Cameron G. McDougall
ISIstván Szikora
István Szikora
PNPeter K. Nelson
Peter K. Nelson
To evaluate the safety and effectiveness of the Pipeline Embolization Device (PED; ev3/Covidien, Irvine, Calif) in the treatment of complex intracranial aneurysms. The Pipeline for Uncoilable or Failed Aneurysms is a multicenter, prospective, interventional, single-arm trial of PED for the treatment of uncoilable or failed aneurysms of the internal carotid artery. Institutional review board approval of the HIPAA-compliant study protocol was obtained from each center. After providing informed consent, 108 patients with recently unruptured large and giant wide-necked aneurysms were enrolled in the study. The primary effectiveness endpoint was angiographic evaluation that demonstrated complete aneurysm occlusion and absence of major stenosis at 180 days. The primary safety endpoint was occurrence of major ipsilateral stroke or neurologic death at 180 days. PED placement was technically successful in 107 of 108 patients (99.1%). Mean aneurysm size was 18.2 mm; 22 aneurysms (20.4%) were giant (>25 mm). Of the 106 aneurysms, 78 met the study's primary effectiveness endpoint (73.6%; 95% posterior probability interval: 64.4%-81.0%). Six of the 107 patients in the safety cohort experienced a major ipsilateral stroke or neurologic death (5.6%; 95% posterior probability interval: 2.6%-11.7%). PED offers a reasonably safe and effective treatment of large or giant intracranial internal carotid artery aneurysms, demonstrated by high rates of complete aneurysm occlusion and low rates of adverse neurologic events; even in aneurysms failing previous alternative treatments.

9 December 2010 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PNP.K. Nelson
P.K. Nelson
PLP. Lylyk
P. Lylyk
ISI. Szikora
I. Szikora
SWS.G. Wetzel
S.G. Wetzel
IWI. Wanke
I. Wanke
DFD. Fiorella
D. Fiorella
Endoluminal reconstruction with flow diverting devices represents a novel constructive technique for the treatment of cerebral aneurysms. We present the results of the first prospective multicenter trial of a flow-diverting construct for the treatment of intracranial aneurysms. Patients with unruptured aneurysms that were wide-necked (> 4 mm), had unfavorable dome/neck ratios (<1.5), or had failed previous therapy were enrolled in the PITA trial between January and May 2007 at 4 (3 European and 1 South American) centers. Aneurysms were treated with the PED with or without adjunctive coil embolization. All patients underwent clinical evaluation at 30 and 180 days and conventional angiography 180 days after treatment. Angiographic results were adjudicated by an experienced neuroradiologist at a nonparticipating site. Thirty-one patients with 31 intracranial aneurysms (6 men; 42-76 years of age; average age, 54.6 years) were treated during the study period. Twenty-eight aneurysms arose from the ICA (5 cavernous, 15 parophthalmic, 4 superior hypophyseal, and 4 posterior communicating segments), 1 from the MCA, 1 from the vertebral artery, and 1 from the vertebrobasilar junction. Mean aneurysm size was 11.5 mm, and mean neck size was 5.8 mm. Twelve (38.7%) aneurysms had failed (or recurred after) a previous endovascular treatment. PED placement was technically successful in 30 of 31 patients (96.8%). Most aneurysms were treated with either 1 (n = 18) or 2 (n = 11) PEDs. Fifteen aneurysms (48.4%) were treated with a PED alone, while 16 were treated with both PED and embolization coils. Two patients experienced major periprocedural stroke. Follow-up angiography demonstrated complete aneurysm occlusion in 28 (93.3%) of the 30 patients who underwent angiographic follow-up. No significant in-construct stenosis (≥ 50%) was identified at follow-up angiography. Intracranial aneurysm treatment with the PED is technically feasible and can be achieved with a safety profile analogous to that reported for stent-supported coil embolization. PED treatment elicited a very high rate (93%) of complete angiographic occlusion at 6 months in a population of the most challenging anatomic subtypes of cerebral aneurysms.

29 October 2014 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
DKDavid F. Kallmes
David F. Kallmes
RHR. Hanel
R. Hanel
DLD. Lopes
D. Lopes
EBE. Boccardi
E. Boccardi
ABA. Bonafe
A. Bonafe
PLP. Lylyk
P. Lylyk
BACKGROUND AND PURPOSE: Flow diverters are increasingly used in the endovascular treatment of intracranial aneurysms. Our aim was to determine neurologic complication rates following Pipeline Embolization Device placement for intracranial aneurysm treatment in a real-world setting. MATERIALS AND METHODS: We retrospectively evaluated all patients with intracranial aneurysms treated with the Pipeline Embolization Device between July 2008 and February 2013 in 17 centers worldwide. We defined 4 subgroups: internal carotid artery aneurysms of ≥10 mm, ICA aneurysms of <10 mm, other anterior circulation aneurysms, and posterior circulation aneurysms. Neurologic complications included spontaneous rupture, intracranial hemorrhage, ischemic stroke, permanent cranial neuropathy, and mortality. Comparisons were made with t tests or ANOVAs for continuous variables and the Pearson χ2 or Fisher exact test for categoric variables. RESULTS: In total, 793 patients with 906 aneurysms were included. The neurologic morbidity and mortality rate was 8.4% (67/793), highest in the posterior circulation group (16.4%, 9/55) and lowest in the ICA <10-mm group (4.8%, 14/294) (P = .01). The spontaneous rupture rate was 0.6% (5/793). The intracranial hemorrhage rate was 2.4% (19/793). Ischemic stroke rates were 4.7% (37/793), highest in patients with posterior circulation aneurysms (7.3%, 4/55) and lowest in the ICA <10-mm group (2.7%, 8/294) (P = .16). Neurologic mortality was 3.8% (30/793), highest in the posterior circulation group (10.9%, 6/55) and lowest in the anterior circulation ICA <10-mm group (1.4%, 4/294) (P < .01). CONCLUSIONS: Aneurysm treatment with the Pipeline Embolization Device is associated with the lowest complication rates when used to treat small ICA aneurysms. Procedure-related morbidity and mortality are higher in the treatment of posterior circulation and giant aneurysms.

11 February 2010 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
ISI. Szikora
I. Szikora
ZBZ. Berentei
Z. Berentei
ZKZsolt Kulcsar
Zsolt Kulcsar
MMM. Marosfoi
M. Marosfoi
ZVZ.S. Vajda
Z.S. Vajda
PNP.K. Nelson
P.K. Nelson
BACKGROUND AND PURPOSE: Aneurysm treatment by intrasaccular packing has been associated with a relatively high rate of recurrence. The use of mesh tubes has recently gained traction as an alternative therapy. This article summarizes the midterm results of using an endoluminal sleeve, the PED, in the treatment of aneurysms. MATERIALS AND METHODS: A total of 19 wide-neck aneurysms were treated in 18 patients: 10 by implantation of PEDs alone and 9 by a combination of PED and coils. Angiographic and clinical results were recorded immediately and at 6 months following treatment. RESULTS: Immediate angiographic occlusion was achieved in 4 and flow reduction, in another 15 aneurysms. Angiography at 6 months demonstrated complete occlusion in 17 and partial filling in 1 of 18 patients. There was no difference between coil-packed and unpacked aneurysms. Of 28 side branches covered by ≥1 device, the ophthalmic artery was absent immediately in 1 and at 6 months in another 2 cases. One patient experienced abrupt in-stent thrombosis resulting in a transient neurologic deficit, and 1 patient died due to rupture of a coexisting aneurysm. All giant aneurysms treated with PED alone were demonstrated by follow-up cross-sectional imaging to have involuted by 6 months. CONCLUSIONS: Treatment of large, wide-neck, or otherwise untreatable aneurysms with functional reconstruction of the parent artery may be achieved with relative safety using dedicated flow-modifying devices with or without adjunctive use of intrasaccular coil packing.

1 May 2007 in Stroke
Verified
Journal Article
Closed access
ABArani Bose
Arani Bose
MHMarius Hartmann
Marius Hartmann
HHHans Henkes
Hans Henkes
HLHon-Man Liu
Hon-Man Liu
MTMichael Mu Huo Teng
Michael Mu Huo Teng
SSSiu Po Sit
Siu Po Sit
Background and Purpose— The purpose of this study was to assess the safety and performance of the Wingspan stent system and Gateway percutaneous transluminal angioplasty balloon catheter in the treatment of high-grade, intracranial atherosclerotic lesions in patients who had failed medical therapy. Methods— In this prospective, multicenter, single-arm study, medically refractory patients with a modified Rankin score ≤3 and recurrent symptoms attributable to angiographically demonstrated intracranial stenosis ≥50% in a vessel 2.5 to 4.5 mm in diameter were enrolled. Intracranial lesions were predilated with an undersized Gateway balloon catheter to 80% of the native vessel diameter, followed by deployment of the self-expanding Wingspan stent to facilitate further remodeling of the atherosclerotic plaque and to maintain vessel patency. Neurologic examinations and angiograms were performed at 6 months after the procedure. Results— Among the 45 patients enrolled, the degree of stenosis was reduced from a baseline of 74.9±9.8% to 31.9±13.6% after stenting and 28±23.2% at the 6-month follow-up. The 30-day composite ipsilateral stroke/death rate was 4.5% (2/44); at the 6-month follow-up, the ipsilateral stroke/death rate was 7.0%, the rate for all strokes was 9.7%, and all-cause mortality was 2.3%. Physician-reported follow-up in 43 patients (average of 13 months) conducted outside the study protocol (not adjudicated by the clinical event committee) reported 1 additional ipsilateral stroke. Conclusions— In medically refractory patients with high-grade intracranial atherosclerotic stenoses, a new treatment paradigm involving predilation with an undersized Gateway percutaneous transluminal angioplasty balloon catheter and placement of a self-expanding Wingspan stent system appears to be safe, may facilitate remodeling, and may contribute to favorable angiographic outcomes.

30 August 2006 in Cerebrovascular Diseases
Verified
Journal Article
Closed access
PDF file
TSThorsten Steiner
Thorsten Steiner
MKMarkku Kaste
Markku Kaste
MFMichael Forsting
Michael Forsting
DMDavid Mendelow
David Mendelow
HKHubert Kwiecinski
Hubert Kwiecinski
WHWerner Hacke
Werner Hacke
This article represents the recommendations for the management of spontaneous intracerebral haemorrhage of the European Stroke Initiative (EUSI). These recommendations are endorsed by the 3 European societies which are represented in the EUSI: the European Stroke Council, the European Neurological Society and the European Federation of Neurological Societies.