Yemi Ojo

Yemi Ojo

Auto-generated profile, based on publicly available information

Yemi Ojo

Department of Engineering, University of Cambridge, Cambridge, U.K.

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2021 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
JWJeremy Watson
Jeremy Watson
YOYemi Ojo
Yemi Ojo
KLKhaled Laib
Khaled Laib
ILIoannis Lestas
Ioannis Lestas
Microgrids are increasingly recognized as a key technology for the integration of distributed energy resources into the power network, allowing local clusters of load and distributed energy resources to operate autonomously. However, microgrid operation brings new challenges, especially in islanded operation as frequency and voltage control are no longer provided by large rotating machines. Instead, the power converters in the microgrid must coordinate to regulate the frequency and voltage and ensure stability. We consider the problem of designing controllers to achieve these objectives. Using passivity theory to derive decentralized stability conditions for the microgrid, we propose a control design method for grid-forming inverters. For the analysis we use higher-order models for the inverters and also advanced dynamic models for the lines with an arbitrarily large number of states. By satisfying the decentralized condition formulated, plug-and-play operation can be achieved with guaranteed stability, and performance can also be improved by incorporating this condition as a constraint in corresponding optimization problems formulated. In addition, our control design can improve the power sharing properties of the microgrid compared to previous non-droop approaches. Finally, realistic simulations confirm that the controller design improves the stability and performance of the power network.

30 January 2023 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Closed access
YOYemi Ojo
Yemi Ojo
JWJeremy Watson
Jeremy Watson
KLKhaled Laib
Khaled Laib
ILIoannis Lestas
Ioannis Lestas
Grid-forming inverter-based autonomous microgrids present new operational challenges as the stabilizing rotational inertia of synchronous machines is absent. The design of efficient control policies for grid-forming inverters is, however, a nontrivial problem where multiple performance objectives need to be satisfied, including voltage/frequency regulation, current limiting capabilities, and active power sharing and a scalable operation. We propose, in this article, a novel control architecture for frequency and voltage control, which allows current limitation via an inner loop, active power sharing via a distributed secondary control policy, and scalability by satisfying a passivity property. In particular, the frequency controller employs the inverter output current and angle to provide an angle droop-like policy, which improves its stability properties. This also allows us to incorporate a secondary control policy for which we provide an analytical stability result, which takes line conductances into account (in contrast to the lossless line assumptions in the literature). The distinctive feature of the voltage control scheme is that it has a double-loop structure that uses the dc voltage in the feedback control policy to implement a power-balancing strategy to improve performance. The performance of the control policy is illustrated via simulations with detailed nonlinear models in a realistic setting.

1 January 2020 in IFAC-PapersOnLine
Verified
Journal Article
Open access
YOYemi Ojo
Yemi Ojo
MBMohammed Benmiloud
Mohammed Benmiloud
ILIoannis Lestas
Ioannis Lestas
Grid-forming inverters play an important role in supporting power systems with low rotational inertia. Their frequency and voltage control policies must guarantee a synchronised operation, accurate power sharing amongst inverters, and a good transient response. Simultaneously achieving the latter two requirements is in general a non-trivial problem and existing schemes in the literature often focus on one of these two aspects. In this paper, we propose a simple frequency controller that uses the inverter output current as feedback to adapt its frequency, and also propose controllers for the regulation of the DC and AC voltages. We show that the proposed control architectures achieve both power sharing without a communication link, and desirable passivity properties that can enhance the dynamic performance. Closed loop stability of the grid-forming inverter with a dynamic load is also proven and simulations on advanced models are carried out to validate the results.

20 June 2024 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
YOYemi Ojo
Yemi Ojo
S M Shafiul AlamS M Shafiul Alam
S M Shafiul Alam
WBW. Hill Balliet
W. Hill Balliet
TMThomas M. Mosier
Thomas M. Mosier
This paper proposes a control architecture for frequency, current, and voltage control that facilitates using battery storage to improve the response of standalone small hydropower plants. The frequency controller uses rate-of-change of frequency and frequency-Watt-based generations to produce active power commands. The distinctive feature of the controller design is that it nicely integrates response to frequency change with constraints on frequency and state of battery to enable power injections. The current and voltage control scheme allows incorporating the frequency controller. The distinctive feature of this controller is that it incorporates a bounded integral control strategy that guarantees stability. Results on the stability of the hydropower plant with proposed scheme are presented and robust ways to choose the controller gains are investigated via root locus analysis. Simulations performed show that: the hydropower plant response is significantly improved with battery storage using the proposed scheme; the load carrying capability of the hydropower plant is significantly improved with battery storage; the proposed scheme has the capability to recharge the battery; and the proposed control scheme gives improved performance.

1 June 2017
Verified
Conference Paper
Closed access
YOYemi Ojo
Yemi Ojo
JSJohannes Schiffer
Johannes Schiffer
Small-signal analysis is one of the most frequently used techniques to assess the operating conditions of power systems. Typically, this analysis is conducted by employing a phasor-based model of the power network derived under the assumption of balanced operating conditions. However, distribution networks and, amongst these, microgrids are often unbalanced. Hence, their analysis requires the development of tools and methods valid under such conditions. Motivated by this, we propose a modeling approach for generic nonlinear and unbalanced three-phase microgrids, which allows to derive a small-signal model in a standard fashion. The approach is based on a time-domain decomposition of the electrical waveforms in positive and negative synchronous reference frames. The efficacy of the approach is demonstrated via application to an exemplary unbalanced microgrid.

2 January 2023 in IEEE Control Systems Letters
Verified
Journal Article
Closed access
YOYemi Ojo
Yemi Ojo
KLKhaled Laib
Khaled Laib
ILIoannis Lestas
Ioannis Lestas
We consider the problem of synchronization of coupled oscillators in an advanced Kuramoto model that includes coupling conductances, and is characterized by nonhomogeneous coupling weights and noncomplete coupling graphs. Lyapunov analysis once such coupling conductances and aforementioned properties are included becomes nontrivial and more conventional energy-like Lyapunov functions are not applicable or are conservative. Small-signal analysis has been performed for such models, but due to the fact that we have convergence to a manifold, stability analysis via a linearization is on its own inconclusive for the nonlinear model. In this paper, we provide a formal derivation using centre manifold theory that if a particular condition on the equilibrium point associated with the coupling conductances and susceptances holds, then the synchronization manifold for the nonlinear system considered is asymptotically stable. Our analysis is demonstrated with simulations.