16 July 2010 in Astronomy & Astrophysics
The Photodetector Array Camera and Spectrometer (PACS) is one of the three science instruments on ESA's far infrared and submillimetre observatory. It employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16×25 pixels, each, and two filled silicon bolometer arrays with 16×32 and 32×64 pixels, respectively, to perform integral-field spectroscopy and imaging photometry in the 60–210 μm wavelength regime. In photometry mode, it simultaneously images two bands, 60–85 μm or 85–125 μm and 125–210 μm, over a field of view of ~1.75'× 3.5', with close to Nyquist beam sampling in each band. In spectroscopy mode, it images a field of 47” × 47”, resolved into 5×5 pixels, with an instantaneous spectral coverage of ~1500 km s-1 and a spectral resolution of ~175 km s-1. We summarise the design of the instrument, describe observing modes, calibration, and data analysis methods, and present our current assessment of the in-orbit performance of the instrument based on the performance verification tests. PACS is fully operational, and the achieved performance is close to or better than the pre-launch predictions.
1 June 2023 in Publications of the Astronomical Society of the Pacific
Twenty-six years ago a small committee report, building on earlier studies, expounded a compelling and poetic vision for the future of astronomy, calling for an infrared-optimized space telescope with an aperture of at least 4 m. With the support of their governments in the US, Europe, and Canada, 20,000 people realized that vision as the 6.5 m James Webb Space Telescope. A generation of astronomers will celebrate their accomplishments for the life of the mission, potentially as long as 20 yr, and beyond. This report and the scientific discoveries that follow are extended thank-you notes to the 20,000 team members. The telescope is working perfectly, with much better image quality than expected. In this and accompanying papers, we give a brief history, describe the observatory, outline its objectives and current observing program, and discuss the inventions and people who made it possible. We cite detailed reports on the design and the measured performance on orbit.
1 April 2023 in Publications of the Astronomical Society of the Pacific
The Mid-Infrared Instrument (MIRI) extends the reach of the James Webb Space Telescope (JWST) to 28.5 μm. It provides subarcsecond-resolution imaging, high sensitivity coronagraphy, and spectroscopy at resolutions of λ/Δλ ∼ 100–3500, with the high-resolution mode employing an integral field unit to provide spatial data cubes. The resulting broad suite of capabilities will enable huge advances in studies over this wavelength range. This overview describes the history of acquiring this capability for JWST. It discusses the basic attributes of the instrument optics, the detector arrays, and the cryocooler that keeps everything at approximately 7 K. It gives a short description of the data pipeline and of the instrument performance demonstrated during JWST commissioning. The bottom line is that the telescope and MIRI are both operating to the standards set by pre-launch predictions, and all of the MIRI capabilities are operating at, or even a bit better than, the level that had been expected. The paper is also designed to act as a roadmap to more detailed papers on different aspects of MIRI.
1 July 2015 in Publications of the Astronomical Society of the Pacific
We describe the design and performance of the Medium Resolution Spectrometer (MRS) for the JWST-MIRI instrument. The MRS incorporates four coaxial spectral channels in a compact opto-mechanical layout that generates spectral images over fields of view up to 7.7 X 7.7 arcseconds in extent and at spectral resolving powers ranging from 1,300 to 3,700. Each channel includes an all-reflective integral field unit (IFU): an 'image slicer' that reformats the input field for presentation to a grating spectrometer. Two 1024 X 1024 focal plane arrays record the output spectral images with an instantaneous spectral coverage of approximately one third of the full wavelength range of each channel. The full 5 to 28.5 micron spectrum is then obtained by making three exposures using gratings and pass-band-determining filters that are selected using just two three-position mechanisms. The expected on-orbit optical performance is presented, based on testing of the MIRI Flight Model and including spectral and spatial coverage and resolution. The point spread function of the reconstructed images is shown to be diffraction limited and the optical transmission is shown to be consistent with the design expectations
7 July 2023 in Astronomy & Astrophysics
Context. The Medium-Resolution Spectrometer (MRS) provides one of the four operating modes of the Mid-Infrared Instrument (MIRI) on board the James Webb Space Telescope (JWST). The MRS is an integral field spectrometer, measuring the spatial and spectral distributions of light across the 5–28 µm wavelength range with a spectral resolving power between 3700 and 1300. Aims. We present the MRS’s optical, spectral, and spectro-photometric performance, as achieved in flight, and we report on the effects that limit the instrument’s ultimate sensitivity. Methods. The MRS flight performance has been quantified using observations of stars, planetary nebulae, and planets in our Solar System. The precision and accuracy of this calibration was checked against celestial calibrators with well-known flux levels and spectral features. Results. We find that the MRS geometric calibration has a distortion solution accuracy relative to the commanded position of 8 mas at 5 µm and 23 mas at 28 µm. The wavelength calibration is accurate to within 9 km s−1 at 5 µm and 27 km s−1 at 28 µm. The uncertainty in the absolute spectro-photometric calibration accuracy was estimated at 5.6 ± 0.7%. The MIRI calibration pipeline is able to suppress the amplitude of spectral fringes to below 1.5% for both extended and point sources across the entire wavelength range. The MRS point spread function (PSF) is 60% broader than the diffraction limit along its long axis at 5 µm and is 15% broader at 28 µm. Conclusions. The MRS flight performance is found to be better than prelaunch expectations. The MRS is one of the most subscribed observing modes of JWST and is yielding many high-profile publications. It is currently humanity’s most powerful instrument for measuring the mid-infrared spectra of celestial sources and is expected to continue as such for many years to come.
27 June 2023 in The Astrophysical Journal Letters
We present the ultraviolet luminosity function and an estimate of the cosmic star formation rate density at 8 < z < 13 derived from deep NIRCam observations taken in parallel with the MIRI Deep Survey of the Hubble Ultra Deep Field (HUDF), NIRCam covering the parallel field 2. Our deep (40 hr) NIRCam observations reach an F277W magnitude of 30.8 (5σ), more than 2 mag deeper than JWST public data sets already analyzed to find high-redshift galaxies. We select a sample of 44 z > 8 galaxy candidates based on their dropout nature in the F115W and/or F150W filters, a high probability for their photometric redshifts, estimated with three different codes, being at z > 8, good fits based on χ 2 calculations, and predominant solutions compared to z < 8 alternatives. We find mild evolution in the luminosity function from z ∼ 13 to z ∼ 8, i.e., only a small increase in the average number density of ∼0.2 dex, while the faint-end slope and absolute magnitude of the knee remain approximately constant, with values α = − 2.2 ± 0.1, and M * = − 20.8 ± 0.2 mag. Comparing our results with the predictions of state-of-the-art galaxy evolution models, we find two main results: (1) a slower increase with time in the cosmic star formation rate density compared to a steeper rise predicted by models; (2) nearly a factor of 10 higher star formation activity concentrated in scales around 2 kpc in galaxies with stellar masses ∼108 M ⊙ during the first 350 Myr of the universe, z ∼ 12, with models matching better the luminosity density observational estimations ∼150 Myr later, by z ∼ 9.