In this paper, we propose and demonstrate a method for enhancing the sensitivity of accelerometers using a thin-cladding weak fiber Bragg grating (WFBG) array. Compared to a 125 $\mu \mathrm{m}$ cladding diameter single-mode fiber (SMF), a thin-cladding fiber (TCF) will produce greater deformation for the same force, resulting in a significant increase in the phase change of the transmitted light. The enhanced sensitivity was verified using a 60 $\mu \mathrm{m}$ diameter SMF in a spring-mass accelerometer structure. The accelerometer has an operating bandwidth of 10 Hz to 400 Hz and a sensitivity of 284.96 rd/g (49.09 dB, ref rad/g), which represents a 9.92 dB increase in sensitivity compared to a 125 $\mu \mathrm{m}$ diameter SMF with a sensitivity of 90.87 rd/g (39.17 dB). The proposed sensitivity enhancement scheme is applicable to almost all interferometric fiber optic accelerometers and offers significant advantages in large-scale quasi-distributed oil and gas exploration and monitoring.
22 July 2025 in IEEE Transactions on Instrumentation and Measurement
In this paper, we propose and demonstrate a fiber three-component accelerometer based on ultra-short fiber Bragg gratings (FBGs) arrays for seismic exploration in oil and gas wells. The three-component accelerometer consists of three orthogonal sensing units, each based on a spring-mass structure and encapsulated in a cylindrical casing that is resistant to temperatures up to 155 °C and pressures of 50 MPa. Ultra-short FBGs, fabricated using femtosecond laser direct writing technology, exhibit a 3 dB bandwidth > 7.10 nm and are used as mirrors for the interferometric three-component sensor, ensuring stable operation of the accelerometer over a wide temperature range [25, 300] °C. Experimental results demonstrate that the accelerometer exhibits excellent linearity, with a sensitivity of 49.14 dB (ref rad/g) measured within the [10, 700] Hz frequency range. The accelerometer has a minimum detectable acceleration (MDA) of 122.80 ng/√Hz and outperforms standard electrical geophones used for surface seismic exploration in comparative tests. To validate the detection performance of the developed fiber-optic three-component accelerometer, it was employed in receiving tests of ground-excited seismic signals in wells and cross-well seismic exploration tests. The proposed fiber interferometric accelerometer demonstrates significant advantages for large-scale quasi-distributed multi-component oil and gas resource exploration and monitoring.
9 October 2025 in IEEE Transactions on Instrumentation and Measurement
An extrinsic three-component accelerometer based on fiber Fabry-Perot (F-P) interferometer is proposed. Unlike the traditional parallel connection, a dedicated filter is proposed to realize single-channel multiplexing of accelerometers. This dedicated filter can serve as a reflective surface for an F-P cavity while also enabling wavelength selection, allowing light of a specific wavelength band to pass through and reflecting light of other bands with minimal loss to the next stage. A hinged diaphragm-type sensing element is optimized by finite element simulation. The performance of the accelerometer is explored with respect to the different free spectral ranges (FSR). The proposed three-component fiber accelerometer has a specific bandwidth of 20 nm for each stage, and the FSR for each stage is 5 nm, the natural frequency of the three-component fiber accelerometer is 680 Hz, the X-axis wavelength sensitivity is 3.01 nm/g, the Y-axis wavelength sensitivity is 3.02 nm/g, the Z-axis wavelength sensitivity is 3.21 nm/g, and the lateral interference ability is less than 6.3%. Finally, surface seismic field tests were performed for both the single-component accelerometer and the three-component accelerometer.
We propose and demonstrate a spring-mass structure accelerometer based on a fiber Bragg grating Fabry–Perot interferometer (FBG-FPI). The sensitivity and resonant frequency of the accelerometer can be adjusted by adding an additional mass block. A theoretical model of the accelerometer was established and simulated using finite element analysis, with experimental verification of the theoretical formulas for its sensitivity and resonant frequency. Experimental results indicate that modifying the additional mass block allows adjustment of the accelerometer’s resonant frequency within the range of 720 Hz to 1200 Hz, achieving a maximum sensitivity of 403.2 rad/g. To further validate the proposed method’s effectiveness, we conducted a comparative test between this accelerometer and a traditional electromagnetic one, confirming its performance and reliability in practical applications.