4 November 2020 in Journal of the Association for Research in Otolaryngology
Variations in neural health along the cochlea can degrade the spectral and temporal representation of sounds conveyed by cochlear implants (CIs). We evaluated and compared one electrophysiological measure and two behavioural measures that have been proposed as estimates of neural health patterns, in order to explore the extent to which the different measures provide converging and consistent neural health estimates. All measures were obtained from the same 11 users of the Cochlear Corporation CI. The two behavioural measures were multipulse integration (MPI) and the polarity effect (PE), both measured on each of seven electrodes per subject. MPI was measured as the difference between thresholds at 80 pps and 1000 pps, and PE as the difference in thresholds between cathodic- and anodic-centred quadraphasic (QP) 80-pps pulse trains. It has been proposed that good neural health corresponds to a large MPI and to a large negative PE (lower thresholds for cathodic than anodic pulses). The electrophysiological measure was the effect of interphase gap (IPG) on the offset of the ECAP amplitude growth function (AGF), which has been correlated with spiral ganglion neuron density in guinea pigs. This ‘IPG offset’ was obtained on the same subset of electrodes used for the behavioural measures. Despite high test–retest reliability, there were no significant correlations between the neural health estimates for either within-subject comparisons across the electrode array, or between-subject comparisons of the means. A phenomenological model of a population of spiral ganglion neurons was then used to investigate physiological mechanisms that might underlie the different neural health estimates. The combined experimental and modelling results provide evidence that PE, MPI and IPG offset may reflect different characteristics of the electrode-neural interface.
13 April 2022 in IEEE Transactions on Biomedical Engineering
Goal: Advances in computational models of biological systems and artificial neural networks enable rapid virtual prototyping of neuroprostheses, accelerating innovation in the field. Here, we present an end-to-end computational model for predicting speech perception with cochlear implants (CI), the most widely-used neuroprosthesis. Methods: The model integrates CI signal processing, a finite element model of the electrically-stimulated cochlea, and an auditory nerve model to predict neural responses to speech stimuli. An automatic speech recognition neural network is then used to extract phoneme-level speech perception from these neural response patterns. Results: Compared to human CI listener data, the model predicts similar patterns of speech perception and misperception, captures between-phoneme differences in perceptibility, and replicates effects of stimulation parameters and noise on speech recognition. Information transmission analysis at different stages along the CI processing chain indicates that the bottleneck of information flow occurs at the electrode-neural interface, corroborating studies in CI listeners. Conclusion: An end-to-end model of CI speech perception replicated phoneme-level CI speech perception patterns, and was used to quantify information degradation through the CI processing chain. Significance: This type of model shows great promise for developing and optimizing new and existing neuroprostheses.
27 October 2020 in Journal of the Association for Research in Otolaryngology
Variations in the condition of the neural population along the length of the cochlea can degrade the spectral and temporal representation of sounds conveyed by CIs, thereby limiting speech perception. One measurement that has been proposed as an estimate of neural survival (the number of remaining functional neurons) or neural health (the health of those remaining neurons) is the effect of stimulation parameters, such as the interphase gap (IPG), on the amplitude growth function (AGF) of the electrically evoked compound action potential (ECAP). The extent to which such measures reflect neural factors, rather than non-neural factors (e.g. electrode orientation, electrode-modiolus distance, and impedance), depends crucially upon how the AGF data are analysed. However, there is currently no consensus in the literature for the correct method to interpret changes in the ECAP AGF due to changes in stimulation parameters. We present a simple theoretical model for the effect of IPG on ECAP AGFs, along with a re-analysis of both animal and human data that measured the IPG effect. Both the theoretical model and the re-analysis of the animal data suggest that the IPG effect on ECAP AGF slope (IPG slope effect), measured using either a linear or logarithmic input-output scale, does not successfully control for the effects of non-neural factors. Both the model and the data suggest that the appropriate method to estimate neural health is by measuring the IPG offset effect, defined as the dB offset between the linear portions of ECAP AGFs for two stimuli differing only in IPG.
15 February 2021 in IEEE Transactions on Biomedical Engineering
Cochlear implants use electrical stimulation of the auditory nerve to restore the sensation of hearing to deaf people. Unfortunately, the stimulation current spreads extensively within the cochlea, resulting in “blurring” of the signal, and hearing that is far from normal. Current spread can be indirectly measured using the implant electrodes for both stimulating and sensing, but this provides incomplete information near the stimulating electrode due to electrode-electrolyte interface effects. Here, we present a 3D-printed “unwrapped” physical cochlea model with integrated sensing wires. We integrate resistors into the walls of the model to simulate current spread through the cochlear bony wall, and “tune” these resistances by calibration with an in-vivo electrical measurement from a cochlear implant patient. We then use this model to compare electrical current spread under different stimulation modes including monopolar, bipolar and tripolar configurations. Importantly, a trade-off is observed between stimulation amplitude and current focusing among different stimulation modes. By combining different stimulation modes and changing intracochlear current sinking configurations in the model, we explore this trade-off between stimulation amplitude and focusing further. These results will inform clinical strategies for use in delivering speech signals to cochlear implant patients.
27 August 2020 in PsyArXiv
The knowledge of patient-specific neural excitation patterns from cochlear implants can provide important information for optimising efficacy and improving speech perception outcomes. The Panoramic ECAP (or ‘PECAP’) method (Cosentino, et al., 2015) uses forward-masked electrically evoked compound action potentials (ECAPs) to estimate neural activation patterns of cochlear implant (CI) stimulation. The algorithm requires ECAPs be measured for loudness-balanced stimuli from all combinations of probe and masker electrodes, and takes advantage of ECAP amplitudes being a result of the overlapping excitatory areas of both probes and maskers. Here we present an improved version of the PECAP algorithm that imposes biologically realistic constraints on the solution and produces separate estimates of current spread and neural health along the length of the electrode array. The algorithm was evaluated for reliability and accuracy in three ways: (1) computer-simulated current-spread and neural-health scenarios, (2) comparisons to psychophysical correlates of neural health and electrode-modiolus distances in human CI users, and (3) detection of simulated neural ‘dead’ regions (using forward masking) in human CI users. The PECAP algorithm reliably estimated the computer simulated scenarios. A moderate but significant negative correlation between focused thresholds and PECAP’s neural health estimates was found, consistent with previous literature. It also correctly identified simulated dead regions in seven CI users. The revised PECAP algorithm provides an estimate of the electrode-to-neuron interface in CIs that could be used to inform and optimize CI stimulation strategies for individual patients in clinical settings.