Background: The fixed-dose combination of vildagliptin (VDG) and dapagliflozin (DGZ) is used in the treatment of type 2 diabetes mellitus. According to the literature survey, RP-HPLC and HPTLC methods have been reported for routine analysis of VDG and DGZ. These chromatographic methods have been developed using potentially neurotoxic and teratogenic solvents, which are unsafe for human and aquatic animal life and hazardous to the environment. These types of organic solvents shall be replaced or reduced during chromatographic analysis of drugs for the safety of human and aquatic animal life and the protection of the environment. The novel white analytical chemistry (WAC) approach has been introduced, which emphasizes robust, green, user-friendly, economical, and rapid analysis of drug samples. Objective: Hence, the WAC-based RP-HPLC method has been developed for the estimation of VDG and DGZ using lower toxic and economical solvents. Method: The development of the RP-HPLC method includes the implementation of the analytical quality by design approach using principles of design of experiments to reduce organic waste generation and regulatory compliance of analytical method. The central composite design was applied for response surface modeling (RSM) and optimization of the RP-HPLC method. The method validation was carried out according to ICH Q2 (R1) guidelines. Results: The fixed-dose combinations of VDG and DGZ were assayed, and results were found in compliance with their labeled claim. The published and proposed RP-HPLC methods were assessed for chromatographic analysis of VDG and DGZ using the Red-Green-Blue (RGB) model, AGREE calculator, Eco-Scale Assessment tool, GAPI software, and NEMI standards. Conclusions: The proposed method was found to be robust, green, economical, and user-friendly for chromatographic analysis of VDG and DGZ. The proposed method can be an economical and eco-friendly analytical tool in the pharmaceutical industry for quality control and routine analysis of fixed-dose combinations of VDG and DGZ. Highlights: Hybrid principles of WAC and analytical quality by design to RP-HPLC method for simultaneous estimation of VDG and DGZ in their fixed-dose combinations.
Background: A variety of chromatographic methods have been published for the stability evaluation of thiocolchicoside (THC) and lornoxicam (LNX). Nevertheless, the development of chromatographic methods requires the use of neurotoxic and teratogenic organic solvents that are detrimental to the environment and harmful to human life. Objectives: Using the principles of design of experiments (DoE), a novel white analytical chemistry-driven stability-indicating high-performance thin-layer chromatographic (SI-HPTLC) method has been developed for the concurrent stability study of THC and LNX. To protect the environment and human life, the stability-indicating HPTLC method was developed using safe organic solvents. Method: Potential analytical method risk parameters (AMRPs) and analytical method performance attributes (AMPAs) were screened using the fractional factorial design. The response surface analysis and optimization of critical AMRPs and AMPAs was carried out using full factorial design. Navigation of the method operable design region (MODR) was used to develop the SI-HPTLC technique. The developed method was validated in accordance with the International Council for Harmonization (ICH) Q2 (R1) guideline. Results: The developed method’s greenness was evaluated using the AGREE (Analytical Procedure Greenness) tool and ESA (Eco-Scale Assessment). The Blue (B) model was used to assess the proposed method’s cost and time efficiency and user-friendliness. For the stability studies of THC and LNX, the 12 principles of WAC (white analytical chemistry) were used to evaluate the published and proposed chromatographic techniques. Conclusions: Compared to previously published chromatographic techniques for studying the stability of THC and LNX, the suggested approach was found to be more affordable, environmentally friendly, and user-friendly. Highlights: The development of a stability-indicating HPTLC method using a novel white analytical chemistry approach and organic solvents with low toxicity potential. Application of the developed method for analysis of the forced degraded sample and fixed-dose combinations of THC and LNX.
Background: The fixed-dose combination (FDC) of vildagliptin (VDG) and remogliflozin etabonate (RGE) is used as antidiabetic medicine. Numerous reverse phase high-pressure liquid chromatographic (RP-HPLC) methods have been reported for the estimation of VDG and RGE using toxic organic solvents such as acetonitrile and methanol. These organic solvents are also hazardous to the environment. Objective: Hence, the robust and green analytical chemistry–based RP-HPLC-PDA method has been developed for chromatographic analysis of VDG and RGE for the safety of analysts and protection of the environment. Method: The multivariate analysis has been carried out for the identification of critical method risk parameters (CMRPs) and critical method performance attributes (CMPAs) using principal component analysis (PCA). The identified CMRPs and CMPAs were linked with each other for optimization of the RP-HPLC-PDA method using DoE-based response surface modeling. The analytical design space (ADS) has been explored for robust chromatographic analysis of VDG and RGE. Results: The chromatographic analysis of VDG and RGE has been carried out using Shim-Pack C18 column (250 mm L, 4.6 mm ID, 5.0 µm PS) and isopropyl alcohol–0.1% (v/v) formic acid (FA) in water (45 + 55, v/v, pH −3.5). The developed method has been validated in accordance with ICH Q2 (R1) guidelines. The method has been applied for the assay of VDG and RGE in their FDCs. The results of the assay were found in compliance with the labeled claims. Conclusions: The developed RP-HPLC-PDA method did not include any toxic or carcinogenic solvents. Hence, it is safe for analysts and the environment. The greenness profiles of the published and proposed RP-HPLC methods were evaluated by the national environmental method index (NEMI) scale, and the analytical greenness scores were calculated using the AGREE software. The developed method can be used as an eco-friendly tool in the pharmaceutical industry for routine analysis and quality control of FDCs of VDG and RGE. Highlights: Development of a green and robust RP-HPLC method for the estimation of VDG and RGE using safe organic solvents. The analytical quality by design (AQbD) approach has been implemented in the development of a method to minimize solvent wastage. The method was applied for the assay of FDCs of VDG and RGE.
Background: White analytical chemistry (WAC) is a recent approach for evaluating analytical procedures based on their effectiveness in validating results, capacity to be environmentally friendly, and economic effectiveness. Objective: The detection of diclofenac sodium (DCF) and thiocolchicoside (THC) simultaneously has been established using a WAC-driven stability-indicating chromatographic method (SICM). Methods: For the concurrent stability study of THC and DCF, the suggested chromatographic technique was developed employing safe and environmentally acceptable organic solvents. To identify critical analytical method parameters (AMPs) and analytical quality attributes (AQAs), a design of experiments (DoE)-based screening design was applied. For the DoE-based response surface modelling (RSM) of critical AMPs and AQAs, the Box–Behnken design (BBD) was employed. Results: A robust SICM was developed by navigating the analytical design space for simultaneous estimation of THC and DCF. IR, NMR, and mass spectral data were used to characterize the degradation products. Red, green, and blue (RGB) models were used to evaluate the suggested method's validation effectiveness, greenness power, and economic efficiency and compared to published chromatographic techniques. The effectiveness of the chromatographic method's validation concerning the International Council for Harmonization (ICH) Q2 (R1) guideline was evaluated using the red model. The analytical greenness (AGREE) evaluation tool and eco-scale assessment (ESA) approach were used to evaluate the green model's methodology. The blue model-based assessment was carried out for comparison of simplicity of instruments handling, cost, and time during sample analysis. The red, blue, and green scores of the techniques were averaged to arrive at the white score of the suggested and reported methods. Conclusion: For the concurrent stability study of THC and DCF, the suggested technique was shown to be validated, environmentally friendly, and cost effective. The suggested approach could be a cost-effective and environmentally friendly analytical technique for determining the stability and monitoring the quality of fixed-dose combinations (FDC) of THC and DCF. Highlights: Stability-indicating HPTLC method was developed for concomitant analysis of THC and DCF using concepts of DoE and WAC.
Oriental Journal of Chemistry is a peer reviewed quarterly research journal of pure and applied chemistry. It publishes standard research papers in almost all thrust areas of current chemistry of academic and commercial importance. It provides a platform for rapid publication of quality research papers, reviews and chemistry letters. Oriental Journal of Chemistry is abstracted and indexed in almost all reputed National and International agencies.
An unambiguous, precise, and accurate approach was created for the contemporaneous assessment of Meropenem (MPM) and Vaborbactam (VBM) in pharmaceutical dosage form and bulk. For the chromatogram, Standard Zorbax column C18 (4.6 x 150 mm, 5 µm) was utilized. Mobility Phase with buffer : One mL of 65 formic acid :35 acetonitrile was poured into a column at a time. 0.1% Formic acid buffer was utilized in this procedure. A constant temperature of 30°C was maintained. The ideal wavelength was chosen as 220 nm. Retention time of VBM and MPM were found to be 3.953, 2.364 minutes . MPM and VBM have respective RSD of 1.3 and 0.6. The recovery rates were 100.31% and 100.30% with MPM and VBM, respectively. LOD and LOQ values for MPM and VBM were 0.53, 1.62, and 0.52, 1.57, respectively, according to the regression models. The regression formula for MPM was y = 21101x + 10155,and for VBM was y = 21037x + 22037. The method was created in a simple and economical way, and it may be applied in many industries for regular quality control testing because the retention and run times were reduced.