Bishwambhar Sengupta

Bishwambhar Sengupta

Auto-generated profile, based on publicly available information

Bishwambhar Sengupta

University of Washington Fred Hutch Cancer Center Seattle Washington USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2015 in RSC Advances
Verified
Journal Article
Closed access
PDF file
BSBishwambhar Sengupta
Bishwambhar Sengupta
WGWren E. Gregory
Wren E. Gregory
JZJingyi Zhu
Jingyi Zhu
SDSiva Dasetty
Siva Dasetty
MKMehmet Karakaya
Mehmet Karakaya
RPRamakrishna Podila
Ramakrishna Podila
The interaction of protein and carbon nanomaterials is influenced by local charge transfer at the defect sites.

20 November 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
Indra J DasIndra J Das
Indra J Das
JSJooyoung J. Sohn
Jooyoung J. Sohn
SLSara N Lim
Sara N Lim
BSBishwambhar Sengupta
Bishwambhar Sengupta
MFMarcos Feijoo
Marcos Feijoo
PYPoonam Yadav
Poonam Yadav
Background: Plastic scintillating detectors (PSD) have gained popularity due to small size and are ideally suited in small‐field dosimetry due to no correction needed and hence detector reading can be compared to dose. Likewise, these detectors are active and water equivalent. A new PSD from Blue Physics is characterized in photon beam.Purpose: Innovation in small‐field dosimetry detector has led us to examine Blue Physics PSD (BP‐PSD) for use in photon beams from linear accelerator.Methods: BP‐PSD was acquired and its characteristics were evaluated in photon beams from a Varian TrueBeam. Data were collected in a 3D water tank. Standard parameters; dose, dose rate, energy, angular dependence and temperature dependence were studied. Depth dose, profiles and output in a reference condition as well as small fields were measured.Results: BP‐PSD is versatile and provides data very similar to an ion chamber when Cerenkov radiation is properly accounted. This device measures data pulse by pulse which very few detectors can perform. The differences between ion chamber data and PSD are < 2% in most cases. The angular dependence is a bit pronounces to 1.5% which is due to PSD housing. Depth dose and profiles are comparable within < 1% to an ion chamber. For small fields this detector provides suitable field output factor compared to other detectors and Monte Carlo (MC) simulated data without any added correction factor.Conclusions: The characteristics of Blue Physics PSD is uniquely suitable in photon beam and more so in small fields. The data are reproducible compared to ion chamber for most parameters and ideally suitable for small‐field dosimetry without any correction factor.

8 September 2015 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
PMPradyumna Mulpur
Pradyumna Mulpur
SYSairam Yadavilli
Sairam Yadavilli
PMPraharsha Mulpur
Praharsha Mulpur
NKNeeharika Kondiparthi
Neeharika Kondiparthi
BSBishwambhar Sengupta
Bishwambhar Sengupta
VKVenkataramaniah Kamisetti
Venkataramaniah Kamisetti
The relatively low sensitivity of fluorescence detection schemes, which are mainly limited by the isotropic nature of fluorophore emission, can be overcome by utilizing surface plasmon coupled emission (SPCE). In this study, we demonstrate directional emission from fluorophores on flexible Ag–C60 SPCE sensor platforms for point-of-care sensing, in healthcare and forensic sensing scenarios, with at least 10 times higher sensitivity than traditional fluorescence sensing schemes. Adopting the highly sensitive Ag–C60 SPCE platform based on glass and novel low-cost flexible substrates, we report the unambiguous detection of acid-fast Mycobacterium tuberculosis (Mtb) bacteria at densities as low as 20 Mtb mm−2; from non-acid-fast bacteria (e.g., E. coli and S. aureus), and the specific on-site detection of acid-fast sperm cells in human semen samples. In combination with the directional emission and high-sensitivity of SPCE platforms, we also demonstrate the utility of smartphones that can replace expensive and cumbersome detectors to enable rapid hand-held detection of analytes in resource-limited settings; a much needed critical advance to biosensors, for developing countries.

21 April 2023 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
KOKyuhak Oh
Kyuhak Oh
MGMary P. Gronberg
Mary P. Gronberg
TNTucker J. Netherton
Tucker J. Netherton
BSBishwambhar Sengupta
Bishwambhar Sengupta
CCCarlos E. Cardenas
Carlos E. Cardenas
EFEric C. Ford
Eric C. Ford
A novel cobalt-60 compensator-based intensity-modulated radiation therapy (IMRT) system was developed for a resource-limited environment but lacked an efficient dose verification algorithm. The aim of this study was to develop a deep-learning-based dose verification algorithm for accurate and rapid dose predictions. A deep-learning network was employed to predict the doses from static fields related to beam commissioning. Inputs were a cube-shaped phantom, a beam binary mask, and an intersecting volume of the phantom and beam binary mask, while output was a 3-dimensional (3D) dose. The same network was extended to predict patient-specific doses for head and neck cancers using two different approaches. A field-based method predicted doses for each field and combined all calculated doses into a plan, while the plan-based method combined all nine fluences into a plan to predict doses. Inputs included patient computed tomography (CT) scans, binary beam masks, and fluence maps truncated to the patient's CT in 3D. For static fields, predictions agreed well with ground truths with average deviations of less than 0.5% for percent depth doses and profiles. Even though the field-based method showed excellent prediction performance for each field, the plan-based method showed better agreement between clinical and predicted dose distributions. The distributed dose deviations for all planned target volumes and organs at risk were within 1.3 Gy. The calculation speed for each case was within two seconds. A deep-learning-based dose verification tool can accurately and rapidly predict doses for a novel cobalt-60 compensator-based IMRT system.

6 January 2023 in Physica Medica
Verified
Journal Article
Closed access
BSBishwambhar Sengupta
Bishwambhar Sengupta
KOKyuhak Oh
Kyuhak Oh
PSPatricia Sponseller
Patricia Sponseller
PZPeter Zaki
Peter Zaki
BEBoryana Eastman
Boryana Eastman
EFEric Ford
Eric Ford

11 November 2024 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
AKAhtesham Ullah Khan
Ahtesham Ullah Khan
BSBishwambhar Sengupta
Bishwambhar Sengupta
Indra J DasIndra J Das
Indra J Das
Objective. Current reference dosimetry methods for spatially fractionated radiation therapy (SFRT) assume a negligible beam quality change, perturbation, or volume-averaging correction factor. Therefore, the aim of this work was to investigate the impact of the grid collimators on the dosimetric characteristics of a 6 MV photon beam. A detector-specific correction factor, k Q grid ,     Q msr   f grid , f msr , was proposed. Several dosimeters were evaluated for their ability to measure both reference dose and grid output factors (GOFs). Approach. A Monte Carlo model of a grid collimator was created to study the change in the depth dose characteristics with the grid collimator. The impact of the collimator on the percent depth dose (PDD), electron contamination, and average photon energy was investigated. The k Q grid ,     Q msr   f grid , f msr correction factors were calculated for two reference-class micro ion chambers. The reference dose and GOFs were measured with a grid collimator using six ion chambers, two silicon diodes, and a diamond detector. Main results. The PDD in the presence of the grid was observed to be steeper compared to the open field. The average photon energy increased from 1.33 MeV to 1.74 MeV with the presence of the grid collimator. The dose contribution by scattered photons was significantly higher at deeper regions for the open field compared to the grid field. The k Q grid ,     Q msr   f grid , f msr correction was calculated to be <0.5%. The reference dose for all detectors, except for the CC13 and CC04 chambers, was within 1% of each other. The CC13 under-responded up to 3.2% due to volume-averaging effects. The GOFs calculated for all detectors, except Razor and A16, were within 1% of each other. Significance. The phantom scatter dictates the change in the PDD with the presence of the grid. The micro ion chambers exhibit negligible k Q grid ,     Q msr   f grid , f msr correction. All detectors, except the CC13 ion chamber, were found to be suitable for SFRT reference dosimetry.