Sara N Lim

Dr. Sara N Lim

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
Indra J DasIndra J Das
Indra J Das
JSJooyoung J. Sohn
Jooyoung J. Sohn
SLSara N Lim
Sara N Lim
BSBishwambhar Sengupta
Bishwambhar Sengupta
MFMarcos Feijoo
Marcos Feijoo
PYPoonam Yadav
Poonam Yadav
Background: Plastic scintillating detectors (PSD) have gained popularity due to small size and are ideally suited in small‐field dosimetry due to no correction needed and hence detector reading can be compared to dose. Likewise, these detectors are active and water equivalent. A new PSD from Blue Physics is characterized in photon beam.Purpose: Innovation in small‐field dosimetry detector has led us to examine Blue Physics PSD (BP‐PSD) for use in photon beams from linear accelerator.Methods: BP‐PSD was acquired and its characteristics were evaluated in photon beams from a Varian TrueBeam. Data were collected in a 3D water tank. Standard parameters; dose, dose rate, energy, angular dependence and temperature dependence were studied. Depth dose, profiles and output in a reference condition as well as small fields were measured.Results: BP‐PSD is versatile and provides data very similar to an ion chamber when Cerenkov radiation is properly accounted. This device measures data pulse by pulse which very few detectors can perform. The differences between ion chamber data and PSD are < 2% in most cases. The angular dependence is a bit pronounces to 1.5% which is due to PSD housing. Depth dose and profiles are comparable within < 1% to an ion chamber. For small fields this detector provides suitable field output factor compared to other detectors and Monte Carlo (MC) simulated data without any added correction factor.Conclusions: The characteristics of Blue Physics PSD is uniquely suitable in photon beam and more so in small fields. The data are reproducible compared to ion chamber for most parameters and ideally suitable for small‐field dosimetry without any correction factor.

Verified
Journal Article
Open access
PDF file
YLYirong Liu
Yirong Liu
BCBrian Chou
Brian Chou
AYAmulya Yalamanchili
Amulya Yalamanchili
SLSara N Lim
Sara N Lim
LDLaura A. Dawson
Laura A. Dawson
TTTarita O Thomas
Tarita O Thomas
Hepatocellular carcinoma (HCC) is the most common liver tumor, with a continually rising incidence. The curative treatment for HCC is surgical resection or liver transplantation; however, only a small portion of patients are eligible due to local tumor burden or underlying liver dysfunction. Most HCC patients receive nonsurgical liver-directed therapies (LDTs), including thermal ablation, transarterial chemoembolization (TACE), transarterial radioembolization (TARE), and external beam radiation therapy (EBRT). Stereotactic ablative body radiation (SABR) is a specific type of EBRT that can precisely deliver a high dose of radiation to ablate tumor cells using a small number of treatments (or fractions, typically 5 or less). With onboard MRI imaging, MRI-guided SABR can improve therapeutic dose while minimizing normal tissue exposure. In the current review, we discuss different LDTs and compare them with EBRT, specifically SABR. The emerging MRI-guided adaptive radiation therapy has been reviewed, highlighting its advantages and potential role in HCC management.

22 June 2023 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
JSJames J. Sohn
James J. Sohn
SLSara N Lim
Sara N Lim
Indra J DasIndra J Das
Indra J Das
PYPoonam Yadav
Poonam Yadav
Periodic imaging quality assurance (QA) of magnetic resonance imaging linear accelerator (MRL) is critical. The feasibility of a new MRL imaging phantom used for QA in the low field was evaluated with automated image analysis of various parameters for accuracy and reproducibility. The new MRL imaging phantom was scanned across every 30 degrees of the gantry, having the on/off state of the linac in a low-field MRL system using three magnetic resonance imaging sequences: true fast imaging with steady-state precession (TrueFISP), T1 weighted (T1W), and T2 weighted (T2W). The DICOM files were used to calculate the imaging parameters: geometric distortion, uniformity, resolution, signal-to-noise ratio (SNR), and laser alignment. The point spread function (PSF) and edge spread function (ESF) were also calculated for resolution analysis. The phantom data showed a small standard deviation - and high consistency for each imaging parameter. The highest variability in data was observed with the true fast imaging sequence at the calibration angle, which was expected because of low resolution and short scan time (25 sec). The mean magnitude of the largest distortion measured within 200 mm diameter with TrueFISP was 0.31 ± 0.05 mm. The PSF, ESF, signal uniformity, and SNR measurements remained consistent. Laser alignment traditional offsets and angular deviation remained consistent. The new MRL imaging phantom is reliable, reproducible, time effective, and easy to use for a 0.35 T MRL system. The results promise a more streamlined, time-saving, and error-free QA process for low-field MRL adapted in our clinical setting.

25 October 2024 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
SLSara N Lim
Sara N Lim
JSJames J Sohn
James J Sohn
SKSlade J Klawikowski
Slade J Klawikowski
JHJohn P Hayes
John P Hayes
EDEric Donnelly
Eric Donnelly
Indra J DasIndra J Das
Indra J Das
Purpose. Bolus is often required for targets close to or on skin surface, however, standard bolus on complex surfaces can result in air gaps that compromise dosimetry. Brass mesh boluses (RPD, Inc., Albertville, MN) are designed to conform to the patient’s surface and reduce air gaps. While they have been well characterized for their use with photons, minimal characterization exists in literature for their use with electrons. Methods and materials. Dosimetric characteristics of brass mesh bolus was investigated for use with 6, 9 and 12 MeV electrons using a 10 × 10 cm2 applicator on standard multi-energy LINAC. Measurements for bolus equivalence and percentage depth doses (PDDs) under brass mesh, as well as surface dose measurements were performed on solid water and a 3D printed resin breast phantom (Anycubic Photon MonoX, Shenzhen, China) using Markus® parallel-plate ionization chamber (Model 34045, PTW Freiburg, Germany), thermoluminescent detectors (TLD) and EBRT film. After obtaining surface dose measurements, these were compared to dose calculated on the Pinnacle3 treatment planning system (TPS, 16.2, Koninklijke Philips N.V.). Results. Measurements of surface dose under brass mesh showed consistently higher dose than without bolus, confirming that brass mesh can increase the PDD at surface up to ∼ 94% of dose at dmax, depending on incident electron energy. This increase is equivalent to using ∼ 7.2 mm water equivalent bolus for 6 MeV, ∼ 3.6 mm for 9 MeV and ∼ 2.2 mm bolus for 12 MeV electrons. TPS results showed close agreement with in-vivo measurements, confirming the potential for brass mesh as bolus for electron irradiation, provided blousing effect is correctly modelled. Conclusions. To increase electron surface dose, a brass mesh can be used with equivalent effect of water-density bolus varying with electron energy. Proper implementation could allow for ease of treatment, as well as increase bolus conformality in electron-only plans.

21 March 2024
Verified
Book Chapter
Closed access
PDF file
EHElizabeth Huynh
Elizabeth Huynh
EOEenas A. Omari
Eenas A. Omari
SLSara N Lim
Sara N Lim
RMRaymond H. Mak
Raymond H. Mak

19 April 2025 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
SLSara N Lim
Sara N Lim
YLYirong Liu
Yirong Liu
AJAnugayathri Jawahar
Anugayathri Jawahar
BMBharat B. Mittal
Bharat B. Mittal
TTTarita O. Thomas
Tarita O. Thomas
Trials have been performed on irradiating celiac plexus for pancreatic cancer pain management. Images from a combined magnetic resonance imaging and linear accelerator system (MR-linac) for ten patients were assessed for delineation of celiac ganglia, aiming for smaller target volumes and reducing treatment risks versus standard linac-based treatments. MRI-linacs showed superior soft tissue contrast, enabling increased dose to ganglia while irradiating smaller target volumes versus regular linacs (median: 0.8 cm3 vs. 32.2 cm3, p < 0.05 for ten pairs of plans). While further studies are needed, MR-linac treatments could improve targeting precision, minimize dose to organs-at-risk and enhance effectiveness in palliative care.