Mathias Davids

Mathias Davids

Auto-generated profile, based on publicly available information

Mathias Davids

A. A. Martinos Center for Biomedical Imaging, Department of Radiology Massachusetts General Hospital Charlestown Massachusetts USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2022 in NeuroImage
Verified
Journal Article
Open access
QFQiuyun Fan
Qiuyun Fan
CECornelius Eichner
Cornelius Eichner
MAMaryam Afzali
Maryam Afzali
LMLars Mueller
Lars Mueller
CTChantal M.W. Tax
Chantal M.W. Tax
SHSusie Y. Huang
Susie Y. Huang
Tremendous efforts have been made in the last decade to advance cutting-edge MRI technology in pursuit of mapping structural connectivity in the living human brain with unprecedented sensitivity and speed. The first Connectom 3T MRI scanner equipped with a 300 mT/m whole-body gradient system was installed at the Massachusetts General Hospital in 2011 and was specifically constructed as part of the Human Connectome Project. Since that time, numerous technological advances have been made to enable the broader use of the Connectom high gradient system for diffusion tractography and tissue microstructure studies and leverage its unique advantages and sensitivity to resolving macroscopic and microscopic structural information in neural tissue for clinical and neuroscientific studies. The goal of this review article is to summarize the technical developments that have emerged in the last decade to support and promote large-scale and scientific studies of the human brain using the Connectom scanner. We provide a brief historical perspective on the development of Connectom gradient technology and the efforts that led to the installation of three other Connectom 3T MRI scanners worldwide – one in the United Kingdom in Cardiff, Wales, another in continental Europe in Leipzig, Germany, and the latest in Asia in Shanghai, China. We summarize the key developments in gradient hardware and image acquisition technology that have formed the backbone of Connectom-related research efforts, including the rich array of high-sensitivity receiver coils, pulse sequences, image artifact correction strategies and data preprocessing methods needed to optimize the quality of high-gradient strength diffusion MRI data for subsequent analyses. Finally, we review the scientific impact of the Connectom MRI scanner, including advances in diffusion tractography, tissue microstructural imaging, ex vivo validation, and clinical investigations that have been enabled by Connectom technology. We conclude with brief insights into the unique value of strong gradients for diffusion MRI and where the field is headed in the coming years.

11 September 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
MDMathias Davids
Mathias Davids
BGBastien Guerin
Bastien Guerin
VKValerie Klein
Valerie Klein
LWLawrence L. Wald
Lawrence L. Wald
Peripheral Nerve Stimulation (PNS) limits the acquisition rate of Magnetic Resonance Imaging data for fast sequences employing powerful gradient systems. The PNS characteristics are currently assessed after the coil design phase in experimental stimulation studies using constructed coil prototypes. This makes it difficult to find design modifications that can reduce PNS. Here, we demonstrate a direct approach for incorporation of PNS effects into the coil optimization process. Knowledge about the interactions between the applied magnetic fields and peripheral nerves allows the optimizer to identify coil solutions that minimize PNS while satisfying the traditional engineering constraints. We compare the simulated thresholds of PNS-optimized body and head gradients to conventional designs, and find an up to 2-fold reduction in PNS propensity with moderate penalties in coil inductance and field linearity, potentially doubling the image encoding performance that can be safely used in humans. The same framework may be useful in designing and operating magneto- and electro-stimulation devices.

16 July 2025 in Nature Biomedical Engineering
Verified
Journal Article
Open access
PDF file
GRGabriel Ramos-Llordén
Gabriel Ramos-Llordén
HLHong-Hsi Lee
Hong-Hsi Lee
MDMathias Davids
Mathias Davids
PDPeter Dietz
Peter Dietz
AKAndreas Krug
Andreas Krug
SHSusie Y. Huang
Susie Y. Huang
Defining the connectome, the complete matrix of structural connections between the nervous system nodes, is a challenge for human systems neuroscience due to the range of scales that must be bridged. Here we report the design of the Connectome 2.0 human magnetic resonance imaging (MRI) scanner to perform connectomics at the mesoscopic and microscopic scales with strong gradients for in vivo human imaging. We construct a 3-layer head-only gradient coil optimized to minimize peripheral nerve stimulation while achieving a gradient strength of 500 mT m −1 and a slew rate of 600 T m −1 s −1 , corresponding to a 5-fold greater gradient performance than state-of-the-art research gradient systems, including the original Connectome (Connectome 1.0) scanner. We find that gains in sensitivity of up to two times were achieved by integrating a 72-channel in vivo head coil and a 64-channel ex vivo whole-brain radiofrequency coil with built-in field monitoring for data fidelity. We demonstrate mapping of fine white matter pathways and inferences of cellular and axonal size and morphology approaching the single-micron level, with at least a 30% sensitivity improvement compared with Connectome 1.0.

10 October 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
JSJason P. Stockmann
Jason P. Stockmann
NANicolas S. Arango
Nicolas S. Arango
TWThomas Witzel
Thomas Witzel
AMAzma Mareyam
Azma Mareyam
CSCharlotte Sappo
Charlotte Sappo
LWLawrence L. Wald
Lawrence L. Wald

13 April 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
MDMathias Davids
Mathias Davids
PDPeter Dietz
Peter Dietz
GRGudrun Ruyters
Gudrun Ruyters
MRManuela Roesler
Manuela Roesler
VKValerie Klein
Valerie Klein
LWLawrence L Wald
Lawrence L Wald

14 January 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
MDMathias Davids
Mathias Davids
BGBastien Guérin
Bastien Guérin
VKValerie Klein
Valerie Klein
MSMartin Schmelz
Martin Schmelz
LSLothar R Schad
Lothar R Schad
LWLawrence L Wald
Lawrence L Wald
Objective . We present a PNS oracle, which solves these computation time and linearity problems and is, therefore, well-suited for fast optimization of voltage distributions in contact electrode arrays and current drive patterns in non-contact magnetic coil arrays. Approach . The PNS oracle metric for a nerve fiber is computed from an electric field map using only linear operations (projection, differentiation, convolution, scaling). Due to its linearity, this PNS metric can be precomputed for a set of coil or electrode segments, allowing rapid PNS prediction and comparison of any possible coil or electrode stimulation configuration constructed from this set. The PNS oracle is closely related to the classical activating function and modified driving functions but is adjusted to better correlate with full neurodynamic modeling of myelinated mammalian nerves. Main results . We validated the PNS oracle in three MRI gradient coils and two body models and found good correlation between the PNS oracle and the full neurodynamic modeling approach ( R 2 > 0.995). Finally, we demonstrated its potential utility by optimizing the driving currents and voltages of arrays of 108 magnetic coils or 108 contact electrodes to selectively stimulate target nerves in the lower leg. Significance . Peripheral nerve stimulation (PNS) by electromagnetic fields can be accurately simulated using coupled electromagnetic and neurodynamic modeling. Such simulations are slow and non-linear in the electric field, which makes it difficult to iteratively optimize coil and electrode configurations or drive patterns aiming to avoid PNS or to initiate it for therapeutic purposes.