Bin Li

Bin Li

Auto-generated profile, based on publicly available information

Bin Li

School of Electrical and Control Engineering, Liaoning Technical University, Huludao, China

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2015 in RSC Advances
Verified
Journal Article
Closed access
PDF file
LWLidong Wang
Lidong Wang
YCYe Cui
Ye Cui
BLBin Li
Bin Li
SYShuai Yang
Shuai Yang
RLRuiyu Li
Ruiyu Li
WFWeidong Fei
Weidong Fei
The RGO sheets are homogeneously distributed in the RGO/Cu composite produced by the molecular-level mixing and high-shear mixing method and the composites with high mechanical properties are obtained.

22 September 2020 in IEEE Access
Verified
Journal Article
Open access
BLBin Li
Bin Li
CLChenyu Luo
Chenyu Luo
ZWZhiyong Wang
Zhiyong Wang
High-speed train will produce pantograph arc during the driving process, which is harmful to pantograph-catenary system. In order to reduce pantograph-catenary system damage, a method based on Gray Wolf algorithm to optimize the binary Support Vector Machine classifier to identify pantograph arc is proposed. In this paper, 5 groups of pantograph current experiments under different conditions are carried out, and the current data in the pantograph-catenary system under different conditions are measured. The current data state obtained from the pantograph experiments is divided into normal current state and arc current state. Select the mean value, variance, standard deviation, mean value of the first-order difference, and mean value of the second-order difference of the current data as the characteristic value of the pantograph current, and calculate the contribution rate of each characteristic value at the same time, then the current eigenvalue data with a high contribution rate is used as a training sample for learning and recognition through the classifier optimized by Gray Wolf algorithm. The experimental results show that the Gray Wolf optimization algorithm can quickly and accurately identify the pantograph arc, and the classification model obtained is more accurate than the commonly used optimization algorithms such as genetic algorithm and particle swarm. In addition, an engineering implementation of on-line identification of pantograph arc based on industrial computer is proposed.

15 January 2024 in IEEE Access
Verified
Journal Article
Open access
BLBin Li
Bin Li
JWJinglong Wu
Jinglong Wu
The current of the residential series arc fault is affected by the load type, and the fault feature change is not obvious and contains noise. Therefore, the extraction of fault features will affect the arc fault detection results. To solve this problem, an improved salp swarm optimization algorithm combined with variational mode decomposition is proposed to extract the characteristics of current signal, improve the decomposition effect of current signal, and construct a dataset that can fully reflect the characteristics of arc fault. The ReliefF algorithm is designed to combine minimum redundancy maximum relevance to reduce the feature dimension and eliminate redundancy. Finally, the random forest model is used to diagnose the fault, which can quickly detect the fault and does not cause overfitting. Experiments based on the self–built sample set prove that the arc fault can be quickly detected under different acquisition frequencies and noise environments, and the detection rate is more than 95%.

15 December 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BLBin Li
Bin Li
ZBZhiqiang Bian
Zhiqiang Bian
ZWZhiyong Wang
Zhiyong Wang
The failure of AC relay contacts will cause electrical control system fault, which will bring certain economic losses. Therefore, the accurate prediction and evaluation of the electrical life of the relay have certain research value and practical significance. The measurement of the contact resistance of the relay was performed by using a self-designed experimental platform. An electrical life prediction method of AC relay was proposed. Firstly, the measured contact resistance signal was decomposed by using empirical mode decomposition (EMD), and several sub-sequence components and residual components were obtained. Secondly, the prediction of these components was conducted by using a long short-term memory neural network (LSTM), and the prediction value was reconstructed. Thirdly, the Group Method of Data Handling (GMDH) algorithm and Harris Hawk optimization (HHO) algorithm were used to optimize the LSTM. Finally, contact pressure was calculated by using the predicted contact resistance. And the electrical life of the relay was predicted according to a contact pressure based electrical life criterion. Compared with other models, the prediction accuracy of the contact resistance is higher. The electrical life of the relay can be predicted effectively by using the prediction results of both contact resistance and contact pressure. In practical application, a pressure sensor can be installed in the relay, and the electrical life of the contact can be predicted by the measured contact pressure.