Ann-Kathrin Einfeldt

Ann-Kathrin Einfeldt

Auto-generated profile, based on publicly available information

Ann-Kathrin Einfeldt

Affiliation Laboratory for Biomechanics and Biomaterials, Department of Orthopedic Surgery, Hannover Medical School, Hannover, Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AEAnn-Kathrin Einfeldt
Ann-Kathrin Einfeldt
FRFranziska Rebmann
Franziska Rebmann
DYDawei Yao
Dawei Yao
CSChristina Stukenborg-Colsmann
Christina Stukenborg-Colsmann
CHChristof Hurschler
Christof Hurschler
Eike JakubowitzEike Jakubowitz
Eike Jakubowitz
Background: High rejection rates of upper limb prosthetics indicate that current prosthetic devices only partially meet user demands. This study therefore investigated the benefits and challenges with current prostheses, associated services and potential areas for improvement from the perspective of upper limb prosthesis users and various professionals working in the field of upper limb and hand prosthetics. Methods and findings: Seven different focus group discussions were conducted with 32 participants. Participants were grouped by prosthesis type, if they were prosthesis users, or professionals. All focus group discussions were transcribed verbatim, and a summarizing content analysis was performed. Three main topic areas to be addressed emerged from the interviews: 1. a properly functioning prosthesis, 2. the infrastructure, and 3. users’ psychological and physical prerequisites. The interaction between a well-functioning prosthesis and a well-developed infrastructure was shown to be important for successful use. Conclusions: Our study raises many of the same issues that have been reported in previous qualitative studies, dating back over several decades. This study underlines the need to include users and professionals in the future development of prosthetic devices.

8 November 2023 in Injury
Verified
Journal Article
Closed access
JMJorge Mayor
Jorge Mayor
VBVera Birgel
Vera Birgel
JCJan-Dierk Clausen
Jan-Dierk Clausen
GAGökmen Aktas
Gökmen Aktas
SSStephan Sehmisch
Stephan Sehmisch
Emmanouil LiodakisEmmanouil Liodakis
Emmanouil Liodakis

11 March 2026 in JMIR Formative Research
Verified
Journal Article
Open access
IPImke Pitz
Imke Pitz
AEAnn-Kathrin Einfeldt
Ann-Kathrin Einfeldt
AWAnnika Michaela Willnat
Annika Michaela Willnat
PJPatrick Patrick Jahn
Patrick Patrick Jahn
CRChristoph Russmann
Christoph Russmann

11 March 2026 in JMIR Preprints
Verified
Preprint
Open access
IPImke Pitz
Imke Pitz
AEAnn-Kathrin Einfeldt
Ann-Kathrin Einfeldt
AWAnnika Michaela Willnat
Annika Michaela Willnat
PJPatrick Patrick Jahn
Patrick Patrick Jahn
CRChristoph Russmann
Christoph Russmann
BACKGROUND Passive exoskeletons are implemented in occupational settings to reduce physical strain and muscle activity during demanding tasks. Surface electromyography (sEMG) is commonly used to quantify these effects, but sEMG signal acquisition in exoskeleton applications is often compromised by mechanical artifacts from exoskeleton–sensor interaction. Existing standards for sEMG electrode placement and data processing rarely address these challenges. Additionally, extensive signal filtering can remove relevant muscle activity information. OBJECTIVE This experimental study aimed to evaluate custom 3D-printed covers (‘boxes’) for dry sEMG electrodes, designed to protect sensors from simulated exoskeleton related perturbations. We hypothesized that these covers would reduce motion artifacts and improve signal integrity without affecting skin physiology. METHODS Twenty-three healthy adults participated. Dry sEMG electrodes (Delsys Trigno Mini/ Avanti) were attached to the right and left vastus medialis muscles. A 3D printed cover (‘small Box or large Box’ depending on sensor size) was attached to the skin over the sensors. Each participant performed knee extension tasks under six conditions, combining two cover states (NoBox, Box) and three types of mechanical perturbation (none, vertical load, lateral load). Loads of 3.35 kg simulated typical exoskeleton-induced disturbances. sEMG data were rectified and normalized to maximal voluntary contraction (%MVC). Signal quality was evaluated using RMS amplitude in %MVC, standard deviation, frequency-domain SNR via fast Fourier transformation (FFT), and time synchronization using dynamic time warping (DTW). Skin temperature and electrical resistance due to skin moisture were monitored. Linear mixed-effects models and paired t-tests were used for analysis. RESULTS Application of the boxes resulted in reduced mean muscle activation during mechanical perturbations (vertical: –3.61% MVC, lateral: –2.17% MVC; both P <.001), lower within-trial variability (e.g., lateral perturbation ΔSD: –5.86, P <.001), and higher SNR compared to uncovered conditions (ΔSNR up to +1.10, P <.001). Skin temperature, resistance, and baseline noise were not influenced by the box (all P >.05). The large cover yielded inconsistent results, with some reduction in variability during perturbation (lateral ΔSD: –2.86, P <.001), but lower SNR and more variability in unperturbed trials compared to NoBox. CONCLUSIONS The small 3D-printed box stabilizes the sEMG signal by mechanically shielding the sensor from external disturbances and reducing motion artifacts. Consistency and reliability of sEMG recordings are enhanced without negatively affecting local skin temperature and resistance. The medical adhesive, used to attach the box to the skin, further improves signal quality by limiting lateral dissipation and providing a localized measurement area beneath the box. In contrast, inadequate anatomical fit of the large box may introduce additional variability rather than reduce disturbances. Our study demonstrates that a small, anatomically designed protective cover can effectively reduce motion artifacts and improve sEMG signal quality during mechanical perturbations, without interfering with physiological skin parameters. This approach represents a promising method for enhancing the reliability of sEMG measurements in exoskeleton studies. CLINICALTRIAL German Clinical Trials Register (Germany), DRKS00035777; https://drks.de/search/en/trial/DRKS00035777