Benjamin Hohermuth

Benjamin Hohermuth

Auto-generated profile, based on publicly available information

Benjamin Hohermuth

ETH Zurich

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in International Journal of Multiphase Flow
Verified
Journal Article
Closed access
SFStefan Felder
Stefan Felder
BHBenjamin Hohermuth
Benjamin Hohermuth
RBRobert M. Boes
Robert M. Boes

1 November 2021 in Journal of Hydraulic Engineering
Verified
Journal Article
Closed access
PDF file
BHBenjamin Hohermuth
Benjamin Hohermuth
RBRobert M. Boes
Robert M. Boes
SFStefan Felder
Stefan Felder
Aeration occurs in many natural and human-made flows and must be considered in engineering design. In water infrastructure, air–water flows can be violent and of very high velocity. To date, most fundamental research and engineering design guidelines involving air–water flows have been based upon laboratory scale measurements with limited validation at prototype scale with larger Reynolds numbers. Herein, unique measurements were conducted in high-velocity air–water flows in the tunnel chute of the 225-m-high Luzzone arch Dam in Switzerland. For each of the two test series, an array of 16 double-tip conductivity probes was installed in the circular tunnel chute of 3 m diameter and slope of ≈37° measuring void fraction, bubble count rate, interfacial velocity, and droplet sizes for four different discharges of up to 15.9  m3/s corresponding to Reynolds numbers of up to 2.4 × 107 and mean flow velocities of up to 38  m/s . Void fraction and interfacial velocity distributions, as well as design parameters such as depth-averaged void fractions and flow resistance, compared well with previous laboratory studies and empirical equations. The droplet chord sizes exhibited scale effects, and care must be taken if air–water mass transfer and droplet momentum exchange processes are assessed at the laboratory scale.

5 July 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
BHB. Hohermuth
B. Hohermuth
MKMatthias Kramer
Matthias Kramer
SFStefan Felder
Stefan Felder
DVDaniel Valero
Daniel Valero
Gas–liquid flows occur in many natural environments such as breaking waves, river rapids and human-made systems, including nuclear reactors and water treatment or conveyance infrastructure. Such two-phase flows are commonly investigated using phase-detection intrusive probes, yielding velocities that are considered to be directly representative of bubble velocities. Using different state-of-the-art instruments and analysis algorithms, we show that bubble–probe interactions lead to an underestimation of the real bubble velocity due to surface tension. To overcome this velocity bias, a correction method is formulated based on a force balance on the bubble. The proposed methodology allows to assess the bubble–probe interaction bias for various types of gas-liquid flows and to recover the undisturbed real bubble velocity. We show that the velocity bias is strong in laboratory scale investigations and therefore may affect the extrapolation of results to full scale. The correction method increases the accuracy of bubble velocity estimations, thereby enabling a deeper understanding of fundamental gas-liquid flow processes.

17 August 2018 in Water Resources Research
Verified
Journal Article
Open access
PDF file
BHB. Hohermuth
B. Hohermuth
Volker WeitbrechtVolker Weitbrecht
Volker Weitbrecht
This study investigates the influence of bed‐load transport on flow resistance and bed stability in steep step‐pool channels. A total of 86 flume experiments was performed. Stable step‐pool sequences were formed with increasing discharge under clear‐water conditions. The addition of fine bed‐load material to the flow led to a decrease in bed roughness and an increased mobility of step‐forming clasts. Velocity measurements showed that bed‐load transport significantly decreased flow resistance and increased near‐bed velocity for the conditions investigated. A set of existing resistance equations was tested against our data, of which the hydraulic geometry relation performed best. However, none of the existing equations was able to reproduce flow resistance during active bed‐load transport. Two new resistance equations based on a hydraulic geometry approach are proposed for conditions with and without bed‐load transport. The increase in near‐bed velocity associated with bed‐load transport was identified as the main cause for the observed increase in step mobility associated with bed‐load transport. For flows with bed‐load transport, step‐forming clasts were mobilized at discharges some 10% to 30% lower than under clear‐water conditions.

1 August 2020 in Journal of Hydraulic Engineering
Verified
Journal Article
Closed access
PDF file
BHBenjamin Hohermuth
Benjamin Hohermuth
LSLukas Schmocker
Lukas Schmocker
RBRobert M. Boes
Robert M. Boes
Low-level outlets are key safety elements of reservoir dams, especially for structures with high heads. Their main purpose is the regulation and—if required—rapid drawdown of the reservoir water level in case of maintenance works or structural damage to the dam. A common outlet configuration for high-head structures uses a high-pressure vertical slide gate discharging into a free-flow tunnel. The high-speed water jet in the outlet tunnel leads to considerable air entrainment and transport, resulting in negative air pressures, which can aggravate problems with gate vibration, cavitation, and slug flow. Sufficient air supply via an air vent mitigates such problems. However, current methods for estimating the required air demand do not incorporate all factors affecting design of air vents for low-level outlets. Therefore, tests were conducted in a 20.6-m-long hydraulic scale model at heads up to 30 m, to improve the general understanding of aeration processes, to determine the governing parameters affecting air demand, and to formulate a new air demand design equation. The results show that air demand is mainly a function of the Froude number at the vena contracta. Furthermore, the new design equation enables quantifying the effects of the air vent loss coefficient, air vent size, tunnel slope, and tunnel length on air demand.

1 October 2020 in Journal of Hydraulic Research
Verified
Journal Article
Closed access
BHBenjamin Hohermuth
Benjamin Hohermuth
LSLukas Schmocker
Lukas Schmocker
Robert BoesRobert Boes
Robert Boes
DVDavid Florian Vetsch
David Florian Vetsch
Numerical models are used increasingly to tackle aerated flows for example in spillway design. However, these models are usually empirical and often lack thorough calibration. Herein a mixture model is calibrated with experimental data on uniform aerated flow from literature. A commercial code was used to solve the mixture Reynolds-averaged Navier–Stokes equations. Air entrainment was modelled with a turbulent kinetic energy based sub-grid model. The effects of drag, swarm correction and bubble diameter were evaluated with different models for sub-grid scale air-transport. Employing dynamic bubble size calculation and swarm correction resulted in ∼10% typical error in the simulated mixture flow depth and concentration profile for chute slopes from 7.5° to 75° and unit discharges from 0.20 to 0.51 m2 s−1. The obtained calibration parameters are independent of mean air concentration over a wide range of parameters; thereby providing a basis for air entrainment simulations of more complex flows.