12 March 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
WWW. A. Worstell
W. A. Worstell
SSS. Sajedi
S. Sajedi
LBL. Blackberg
L. Blackberg
YFYuemeng Feng
Yuemeng Feng
MAM. J. Aviles
M. J. Aviles
HSH. Sabet
H. Sabet
We have used a sub-picosecond laser with an output trigger synched to a 4GHz oscilloscope sampling at 25 GSa/s to characterize the temporally resolved response of a Large Area Picosecond Photo-Detector (LAPPD) to single photons/photoelectrons. The LAPPD is a large area (20cm x 20cm) photosensor with a nanosecond-width time response arising from its underlying Multi-Channel Plate Photomultiplier Tube (MCP-PMT) structure. We used optical filters to attenuate the laser pulse intensity to single photon level. LAPPD pulses are nearly identical in shape, particularly for pulses whose peak amplitude is a large multiple of our system’s 0.6 mV rms baseline electronic noise. Three waveform timing algorithms were compared in their measurements of the transit time spread (TTS) Gaussian fitted to the distribution of measured Single Photoelectron (SPE) pulse times under zero-width laser excitation: 1) a Constant Fraction algorithm, 2) a Pulse Centroid Timing algorithm, and 3) a Pulse Model Fitting algorithm. The measured SPE values with the three algorithms are: 79 ± 17, 67 ± 15, and 82 ± 20 ps Gaussian sigma, respectively. The LAPPD provides independent voltage control for its photocathode, and at the entry and entry faces of its Chevron Pair of MCPs. We found no or minimal change in TTS with photocathode voltage for pulses >15mV.

16 October 2021
Verified
Conference Paper
Closed access
YFYuemeng Feng
Yuemeng Feng
LBLisa Blackberg
Lisa Blackberg
GFGeorges El Fakhri
Georges El Fakhri
WWWilliam Worstell
William Worstell
HSHamid Sabet
Hamid Sabet
A Dynamic Cardiac SPECT (DC-SPECT) system is being developed at the Massachusetts General Hospital, Harvard, featuring a cardio focus asymmetrical geometry to enable simultaneous high resolution and high sensitivity. We have generated 14 design iterations of the DC-SPECT with varying number of detector heads, system sensitivity, and system resolution. In such asymmetrical geometry the life cycle of design optimization from mechanical drawing to Monte Carlo implementation to image reconstruction and evaluation is long and labor intensive. This work presents a first implementation of List Mode Maximum Likelihood Expectation Maximization (LM-MLEM) reconstruction for the DC-SPECT system to enable fast design optimization using analytical method. We investigate the DC-SPECT system imaging resolution by applying a simple system modeling while implementing LM-MLEM. Results show that without any correction of scattering or attenuation effects, LM-MLEM reconstruction can achieve a 5 mm FWHM spatial resolution. The results agree with the expected performance of the DC-SPECT. Specifically, we show the advantages of analytic based system matrix model over Monte-Carlo (MC) based models. A comparison between images reconstructed by analytic modeling and MC methods is presented.

5 December 2023 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
YFYuemeng Feng
Yuemeng Feng
WWWilliam Worstell
William Worstell
MKMatthew Kupinski
Matthew Kupinski
LFLars R Furenlid
Lars R Furenlid
HSHamid Sabet
Hamid Sabet
The Dynamic Cardiac SPECT (DC-SPECT) system is being developed at the Massachusetts General Hospital, featuring a static cardio focus asymmetrical geometry enabling simultaneous high-resolution and high-sensitivity imaging. Among 14 design iterations of the DC-SPECT with varying number of detector heads, system sensitivity and resolution, the current version under development features 10 mm FWHM geometrical resolution (without resolution recovery) and 0.07% sensitivity at the center of the FOV, this is 1.5× resolution gain and 7× sensitivity gain compared to a conventional dual head gamma camera (0.01% sensitivity and 15-mm resolution). This work presents improvement in imaging resolution by implementing a spatially variant point spread function (SV-PSF) with list mode MLEM reconstruction. A resolution recovery method by PSF deconvolution is validated on list mode MLEM reconstruction for the DC-SPECT. A spatial invariant PSF is included as an additional test to show the influence of the PSF modelling accuracy on reconstructed image quality. We compare the MLEM reconstruction with and without PSF deconvolution; an analytic model is used for the calculation of system response, and the results are compared to the reconstruction with system modelling using Monte Carlo (MC) based methods. Results show that with PSF modelling applied, the quality of the reconstructed image is improved, and the DC-SPECT system can achieve a 4.5 mm central spatial resolution with average 795 counts/Mbq. Both the SV-PSF and the spatial-invariant PSF improve the image quality, and the reconstruction with SV-PSF generates line profiles closer to the ground truth. The results show substantial improvement over the GE Discovery 570c performance (7 mm spatial resolution with an average 460 counts/MBq, 5.8 mm resolution at the FOV center). The impact of PSF deconvolution is significant, improvement of the reconstructed image quality is evident in comparison to MC simulated system matrix with the same sampling size in the simulation.