1 June 2018 in Nanophotonics
Biophotonic imaging has revolutionized the operation room by providing surgeons intraoperative image‐guidance to diagnose tumors more efficiently and to resect tumors with real‐time image navigation. Among many medical imaging modalities, near‐infrared (NIR) light is ideal for image‐guided surgery because it penetrates relatively deeply into living tissue, while nuclear imaging provides quantitative and unlimited depth information. It is therefore ideal to develop an integrated imaging system by combining NIR fluorescence and gamma‐positron imaging to provide surgeons with highly sensitive and quantitative detection of diseases, such as cancer, in real‐time without changing the look of the surgical field. The focus of this review is to provide recent progress in intraoperative biophotonic imaging systems, NIR fluorescence imaging and intraoperative nuclear imaging devices, and their future perspectives for image‐guided interventions.
2 May 2016 in Medical Physics
19 October 2017 in Physics in Medicine & Biology
A tightly focused pulsed laser beam can locally modify the crystal structure inside the bulk of a scintillator. The result is incorporation of so-called optical barriers with a refractive index different from that of the crystal bulk, that can be used to redirect the scintillation light and control the light spread in the detector. We here systematically study the scintillation light transport in detectors fabricated using the laser induced optical barrier technique, and objectively compare their potential performance characteristics with those of the two mainstream detector types: monolithic and mechanically pixelated arrays. Among countless optical barrier patterns, we explore barriers arranged in a pixel-like pattern extending all-the-way or half-way through a 20 mm thick LYSO:Ce crystal. We analyze the performance of the detectors coupled to MPPC arrays, in terms of light response functions, flood maps, line profiles, and light collection efficiency. Our results show that laser-processed detectors with both barrier patterns constitute a new detector category with a behavior between that of the two standard detector types. Results show that when the barrier-crystal interface is smooth, no DOI information can be obtained regardless of barrier refractive index (RI). However, with a rough barrier-crystal interface we can extract multiple levels of DOI. Lower barrier RI results in larger light confinement, leading to better transverse resolution. Furthermore we see that the laser-processed crystals have the potential to increase the light collection efficiency, which could lead to improved energy resolution and potentially better timing resolution due to higher signals. For a laser-processed detector with smooth barrier-crystal interfaces the light collection efficiency is simulated to >42%, and for rough interfaces >73%. The corresponding numbers for a monolithic crystal is 39% with polished surfaces, and 71% with rough surfaces, and for a mechanically pixelated array 35% with polished pixel surfaces and 59% with rough surfaces.
1 January 2022 in Journal of Instrumentation
The intraoperative gamma probe (IPG) based on single gamma-ray detection remains the current gold standard modality for sentinel lymph node identification and tumor removal in cancer patients. However, IPGs do not meet the <5% false negative rate (FNR) requirement, a key metric suggested by the American Society of Clinical Oncology (ASCO). We aim to reduce FNR by using time of flight (TOF) PET detector technology in limited angle geometry system by using only two detector panels in coincidence. For proof of concept, we used two Hamamatsu TOF PET detector modules (C13500-4075YC-12) featuring 12× 12 arrays of 4.14× 4.14× 20 mm3 LFS crystal pixels with 4.2 mm pitch and coupled one-one to silicon photomultiplier (SiPM) pixels. The measured detector coincidence timing resolution (CTR) was 271 ps FWHM for the whole detector. We 3D printed lesion phantom containing spheres 2–10 mm in diameter, representing lymph nodes, and placed it inside a 10-liter warm background water phantom. Experimental results showed that with subminute data acquisition, 6 mm diameter spheres could be identified in the image when a lesion phantom with a 10:1 activity ratio to background was used. The simulation results were in good agreement with the experimental data by resolving 6 mm diameter spherical lesions with a 60 second acquisition time in a 25 cm deep background water phantom with a 10:1 activity ratio. As expected, the image quality improved as the CTR improved in the simulation and with decreasing background water phantom depth or increasing lesion-to-background activity ratio in the experiment. With the results presented here, we concluded that using a limited angle TOF PET detector system is a major step forward for intraoperative applications in that lesion detectability is beyond what conventional gamma- and NIR-based probes could achieve.
29 April 2019 in Physics in Medicine & Biology
With the goal of developing a low-cost scintillator-based photon counting detector (PCD) with high dose efficiency suitable for CT, the light transport characteristics in LYSO:Ce detectors containing laser induced optical barriers (LIOB) are simulated. Light confinement and light collection efficiencies (LCE) are studied for a variety of optical barrier patterns and properties (refractive index (RI) and barrier/crystal interface roughness). Up to 80% confinement is achievable with a simple pixel pattern with one barrier wall separating each pixel coupled one-to-one to a photodetector (PD) pixel. Confinement is heavily dependent on barrier properties, and rough interfaces and higher RI results in increased cross-talk. Three approaches to enhance performance beyond the basic pattern are explored: (1) Multiple barrier walls separating each crystal pixel. (2) Introduction of long and short range confinement by having multiple crystal pixels per PD pixel. (3) Combination of LIOB and laser ablation (LA). (1) Is effective for rough interfaces where confinement can be increased by up to 24% for double compared to single walls. (2) Results in high confinement in the pixel centered on the PD pixel, but lower confinement closer to the PD edge. This feature may be explored to achieve spatial resolution beyond the PD pixel size using light sharing based positioning algorithms. (3) Can increase confinement for smooth interfaces using a smooth ablation in the bottom part of the crystal. A general trend across all configurations is a trade-off between light confinement and LCE. The LCE attainable is found comparable to that for mechanically pixelated arrays. While the confinement achievable with LIOB is always lower compared to a mechanically pixelated array, the former may offer a high level of flexibility in terms of detector design. This, in combination with the possibility to fabricate sub-mm pixels in a cost-effective manner, makes LIOB a promising technology for scintillator-based PCDs.