Illumination stress (IS) and negative bias under illumination stress (NBIS) cause considerable device instability in thin-film transistors based on amorphous In–Ga–Zn–O (a-IGZO). Models using in-gap states are suggested to explain device instability. Therefore, to provide reliably their density of states (DOS), this study investigated the valence band, conduction band, and in-gap states of an a-IGZO thin film. The DOS of in-gap states was directly determined in a dynamic range of six orders of magnitude through constant final state yield spectroscopy (CFS-YS) using low-energy and low-flux photons. Furthermore, light irradiation irreversibly induced extra in-gap states near the Fermi level and shifted the Fermi level to the vacuum level side, which should be related to the device instability due to IS and NBIS. Hard x-ray photoemission spectroscopy and ultraviolet photoemission spectroscopy using synchrotron radiation observed the large DOS of in-gap states near the Fermi level as in previous works. Here, we reveal that they are not intrinsic electronic states of undamaged a-IGZO, but induced by the intense measurement light of synchrotron radiation. This study demonstrates that CFS-YS is useful for determining the reliable DOS of the in-gap states for samples that are sensitive to light irradiation. The absorption spectrum measured through photothermal deflection spectroscopy is interpreted based on DOS directly determined via photoemission spectroscopies. This indicates that the line shape in the energy region below the region assigned to the Urbach tail in previous works actually roughly reflects the DOS of occupied in-gap states.
The energy band structure of the conduction band (energy–momentum relation of electrons) is crucial to understanding the electron transport of crystalline materials. In this paper, we describe an angle-resolved low-energy inverse photoelectron spectroscopy (AR-LEIPS) apparatus that examines the conduction band structures of materials sensitive to the electron beam, such as organic semiconductors and organic–inorganic hybrid perovskites. The principle of this apparatus is based on AR inverse photoelectron spectroscopy. To minimize radiation damage and improve energy resolution, we employed our previous approach used in LEIPS [H. Yoshida, Chem. Phys. Lett. 539–540, 180 (2012)]. We obtained an overall energy resolution of 0.23 eV with a momentum resolution of 0.9 nm−1 at the electron kinetic energy of 2 eV or higher.
A high-current electron source for inverse photoemission spectroscopy is described. The source comprises a thermal cathode electron emission system, an electrostatic deflector-monochromator, and a lens system for variable kinetic energy (1.6–20 eV) at the target. When scaled to the energy resolution, the electron current is an order of magnitude higher than that of previously described electron sources developed in the context of electron energy loss spectroscopy. Surprisingly, the experimentally measured energy resolution turned out to be significantly better than calculated by standard programs, which include the electron–electron repulsion in the continuum approximation. The achieved currents are also significantly higher than predicted. We attribute this “inverse Boersch-effect” to a mechanism of velocity selection in the forward direction by binary electron–electron collisions.
Conservation of energy has become a major concern all over the world. Especially in the domestic area, public buildings, and office buildings, energy supply systems have to be optimized swiftly balancing with the time-dependent energy demand. This paper discusses the exemplary energy assessment of the cogeneration and air-conditioning system on Keio University Shonan Fujisawa Campus with approximately 5,000 students and 200 faculty members. The purpose of the cogeneration system consisting of prime mover and exhaust heat recovery equipment is a contribution to energy conservation. Exhaust heat of the prime mover can be reutilized in form of heated or chilled water by the exhaust heat recovery equipment. Optimized reutilization of exhaust heat shall bring the main benefit for energy conservation. Therefore, the effectiveness of the cogeneration system has been evaluated based on collected annual data of energy consumption on the campus. Furthermore, curtailment of air-conditioning systems during peak load caused by the congestion of the grid power has been examined. In order to optimize the energy management under these conditions, the forecast of power consumption has been discussed, and the relation of power consumption to air temperature has been examined.