Dmitriy Sergeyevich Likhachev

Dmitriy Sergeyevich Likhachev

Auto-generated profile, based on publicly available information

Dmitriy Sergeyevich Likhachev

Institute of Process Equipment, College of Energy Engineering, Zhejiang University 1 , 310027 Hangzhou, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
BCBangxiang Che
Bangxiang Che
NCNING CHU
NING CHU
LCLinlin Cao
Linlin Cao
SSSteffen J. Schmidt
Steffen J. Schmidt
DLDmitriy Likhachev
Dmitriy Likhachev
Dazhuan WuDazhuan Wu
Dazhuan Wu
The control effect of micro-vortex generators (VGs) on the instability of attached cavitation was investigated in a series of experiments. The micro-VGs, located at the leading edge of a NACA0015 hydrofoil, were used to alter the near-wall flow and control the attached cavitation dynamics. The effect of the nondimensional height of micro-VGs on the nondimensional cavity length was quantitatively evaluated by regression equations through response surface methodology. The micro-VGs increased the nondimensional cavity length. The counter-rotating streamwise vortices induced by micro-VGs had a rectifying effect on the near-wall flow and withstood the flow disturbance in the spanwise direction. Additionally, the micro-VGs partially suppressed Rayleigh–Taylor instability and Kelvin–Helmholtz instability arising from reverse flow underneath the cavity. Under a partial cavity oscillation (PCO) condition, the growth of sheet cavitation was highly two-dimensional in the spanwise direction, and the cloud cavity shedding had a strict periodicity with a smaller Strouhal number (St) than for the smooth hydrofoil. The shedding cloud cavity was captured in a single spanwise vortex core, which was advected toward the trailing edge of the hydrofoil. The transition from PCO to transitional cavity oscillation (TCO) occurred when the cavity length was larger than 0.8 of chord length. Under the TCO condition, the concave cavity closure line of sheet cavitation on the hydrofoil showed perfect symmetry and the St was nearly constant. As a result of our investigation, the micro-VGs have high potential to manipulate and control the attached cavitation dynamics.

1 March 2013 in Desalination and Water Treatment
Verified
Journal Article
Open access
DLDmitriy Sergeyevich Likhachev
Dmitriy Sergeyevich Likhachev
FLFeng-Chen Li
Feng-Chen Li
In this paper, modern large-scale industrial water desalination technologies are briefly reviewed and a comparison between their technological characteristics and field of application is presented to indicate possible areas for technology advancement. In addition, recent developments in distillation processes and new desalination methods are introduced for relevant technologies, offering more accessible water supplies. The research was based on both work with analytic materials from large information agencies involved in the desalination industry and research carried out by individual authors and research institutions. The authors discuss the possibility of applying their own technology for water distillation, so called supercavitating evaporation. Analysis of the current situation indicates an increasing trend for reverse osmosis technology for water desalination, the rise of newer technologies and further limitation of thermal methods for heat utilization purposes.

1 April 2019 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
BCBangxiang Che
Bangxiang Che
NCNING CHU
NING CHU
SSSteffen J. Schmidt
Steffen J. Schmidt
LCLinlin Cao
Linlin Cao
DLDmitriy Likhachev
Dmitriy Likhachev
Dazhuan WuDazhuan Wu
Dazhuan Wu
In this study, we investigate the effects of micro vortex generators (VGs) installed close to the leading edge of a quasi-two-dimensional NACA0015 hydrofoil under cavitating and non-cavitating conditions. Our aim is to improve physical insight into interaction mechanisms of the boundary layer with the formation and stability of partial cavities. Under non-cavitating conditions, the proposed micro VGs effectively suppress laminar separation. However, under cavitating conditions, even very small micro VGs within the boundary layer promote the formation of counter-rotating cavitating vortices. In comparison with the smooth hydrofoil surface (without micro VGs), the cavitation onset is shifted toward the leading edge. Additionally, classical “fingering structures” and Tollmien–Schlichting waves are no longer present. Since the onset of the cavity does no longer appear at (or close to) the laminar separation line, a novel onset mechanism is observed experimentally. The mechanism consists of stable vortex cavitation, followed by vortex break-down into bubbly structures that are finally accumulated into an attached cavity region. By reduction in the height of the micro VGs, a delayed vortex break-down is found, leading to an increase in the length of the cavitating vortex pattern. This allows for enhanced control on the cavity dynamics, especially with respect to the penetration depth of the re-entrant jet. As a result of our investigation, we conclude that well suited micro VGs show a high potential to manipulate and control cavity dynamics.

14 June 2013 in Science China Physics, Mechanics & Astronomy
Verified
Journal Article
Closed access
PDF file
DLDmitriy S. Likhachev
Dmitriy S. Likhachev
FLFengChen Li
FengChen Li

1 November 2014 in Desalination and Water Treatment
Verified
Journal Article
Open access
DLDmitriy Sergeevich Likhachev
Dmitriy Sergeevich Likhachev
FLFeng-Chen Li
Feng-Chen Li
Computation results of the supercavitation on a cone in a bounded axial cold water (20°C) flow, obtained by ANSYS13 CFX and FLUENT, are found to correlate with experimental data. CFX solution has captured considerable backflow, and temperature gradient of 7°C between free water stream and steam inside the supercavity, with the average water vapor temperature of supercavity volume equal to 17.8°C, while FLUENT has revealed negligible temperature gradient, and the position of backflow vortex is different. Although we have used the same setup and appropriate meshes for both solvers, due to different cavitation models: mixture Rayleigh–Plesset and Schnerr-Sauer, for CFX and FLUENT, respectively, we have found wide discrepancy in the resulted thermal, mass, and velocity flow fields. Understanding thermal, mass, and velocity fields of the supercavitating flow is important for the development of an industrial application of supercavitation for the design of the evaporators, open-type heat exchangers, coolers, deaerators, mixers, and chemical reactors. The CFX solver have been used for revealing the multiply factor response of the supercavitating flow on the temperature of source water, its inlet velocity, rate of steam extraction from the supercavity, and the degree of flow obstruction by the cavitator. This analysis goes beyond the presently referred experimental results, and the influences of the each factor on the supercavitating flow dynamics have been formulated in respect of the steam volume fraction, steam motion and effective temperature influence on the interphase heat mass transfer.