Paul Trodden

Paul Trodden

Auto-generated profile, based on publicly available information

Paul Trodden

University of Sheffield

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2013 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
WBWaqquas A. Bukhsh
Waqquas A. Bukhsh
AGAndreas Grothey
Andreas Grothey
KMKen I. M. McKinnon
Ken I. M. McKinnon
PTPaul A. Trodden
Paul A. Trodden
The existence of locally optimal solutions to the AC optimal power flow problem (OPF) has been a question of interest for decades. This paper presents examples of local optima on a variety of test networks including modified versions of common networks. We show that local optima can occur because the feasible region is disconnected and/or because of nonlinearities in the constraints. Standard local optimization techniques are shown to converge to these local optima. The voltage bounds of all the examples in this paper are between ±5% and ±10% off-nominal. The examples with local optima are available in an online archive (http://www.maths.ed.ac.uk/optenergy/LocalOpt/) and can be used to test local or global optimization techniques for OPF. Finally we use our test examples to illustrate the behavior of a recent semi-definite programming approach that aims to find the global solution of OPF.

18 December 2013 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
PTPaul A. Trodden
Paul A. Trodden
WBWaqquas Ahmed Bukhsh
Waqquas Ahmed Bukhsh
AGAndreas Grothey
Andreas Grothey
KMKen I. M. McKinnon
Ken I. M. McKinnon
In this paper, a flexible optimization-based framework for intentional islanding is presented. The decision is made of which transmission lines to switch in order to split the network while minimizing disruption, the amount of load shed, or grouping coherent generators. The approach uses a piecewise linear model of AC power flow, which allows the voltage and reactive power to be considered directly when designing the islands. Demonstrations on standard test networks show that solution of the problem provides islands that are balanced in real and reactive power, satisfy AC power flow laws, and have a healthy voltage profile.

24 June 2010 in International Journal of Control
Verified
Journal Article
Closed access
PTPaul Trodden
Paul Trodden
ARArthur Richards
Arthur Richards
This article presents a new form of robust distributed model predictive control (MPC) for multiple dynamically decoupled subsystems, in which distributed control agents exchange plans to achieve satisfaction of coupling constraints. The new method offers greater flexibility in communications than existing robust methods, and relaxes restrictions on the order in which distributed computations are performed. The local controllers use the concept of tube MPC – in which an optimisation designs a tube for the system to follow rather than a trajectory – to achieve robust feasibility and stability despite the presence of persistent, bounded disturbances. A methodical exploration of the trades between performance and communication is provided by numerical simulations of an example scenario. It is shown that at low levels of inter-agent communication, distributed MPC can obtain a lower closed-loop cost than that obtained by a centralised implementation. A further example shows that the flexibility in communications means the new algorithm has a relatively low susceptibility to the adverse effects of delays in computation and communication.

1 July 2012 in Control Engineering Practice
Verified
Journal Article
Closed access
EHEdward N. Hartley
Edward N. Hartley
PTPaul A. Trodden
Paul A. Trodden
ARArthur G. Richards
Arthur G. Richards
JMJan M. Maciejowski
Jan M. Maciejowski

11 March 2016 in IEEE Transactions on Automatic Control
Verified
Journal Article
Closed access
PTPaul Trodden
Paul Trodden
A procedure and theoretical results are presented for the problem of determining a minimal robust positively invariant (RPI) set for a linear discrete-time system subject to unknown, bounded disturbances. The procedure computes, via the solving of a single LP, a polytopic RPI set that is minimal with respect to the family of RPI sets generated from a finite number of inequalities with pre-defined normal vectors.

1 February 2013 in Automatica
Verified
Journal Article
Closed access
PTPaul Trodden
Paul Trodden
ARArthur Richards
Arthur Richards