Advanced district thermal energy systems, which circulate water at temperatures near ambient conditions, and facilitate the utilization of waste heat and renewable thermal sources, can lower the carbon-intensity of urban districts, advancing the U.N. Sustainable Development Goals. Optimization of the network topology — the selection of the best subset of buildings and the best network to connect them, to minimize life cycle cost — can increase adoption of these system in appropriate applications. The potential “solution space” of the topology optimization problem grows factorially with the number of buildings in the district, motivating the consideration of a design heuristic. In this study, a heuristic for the network selection was evaluated with an exhaustive search, for a prototypical four-building district. For the prototypical district considered, the heuristic was effective in selecting an optimal network topology. Additionally, it was found that, in this case, the selection of the subset of buildings was more influential on the life cycle cost than the selection of the network topology. This work is part of a larger effort to develop a topology optimization framework for district thermal energy systems, which is anticipated to address barriers to adoption of ambient-temperature systems.
Distributed electric generation systems are increasingly considered to offset energy costs and carbon emissions of large building complexes. College campuses, with their physical compactness, and diversity in building loads, present a common application for distributed generation systems. This paper presents the analysis approach and the main results of a feasibility study of a distributed generation system to supply electric and thermal energy for a large university campus, incorporating energy efficiency measures, to reduce carbon emissions at minimal life cycle cost. The presented study uses a load profile developed based on calibrated detailed simulation energy models for prototypical campus buildings. The calibration analysis is carried out using measured energy consumption data, at the individual building level, and the whole-campus level. Several combinations of distributed generation options are evaluated, using an hourly optimization analysis tool, to meet the entire campus hourly electrical and thermal loads. Proposed efficiency measures and distributed generation options are evaluated using different indicators, including life cycle cost and carbon emissions. The analysis results indicate that implementing energy efficiency measures to reduce electrical and thermal loads before implementing distributed generation options is the most cost-effective approach to reducing the campus’s energy-related carbon emissions. The results of the study are summarized to guide college campuses and managers of other urban districts as they adapt to a changing energy landscape.
This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. Advanced rooftop unit controls (ARC) generally consist of a supply fan VFD, and controls to implement demand controlled ventilation (DCV) and air-side economizing, as a retrofit to improve energy efficiency of existing rooftop units (RTUs).