Maria Varnava

Maria Varnava

Auto-generated profile, based on publicly available information

Maria Varnava

Gunma University Heavy Ion Medical Center Maebashi Gunma Japan

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2023 in Cancer Medicine
Verified
Journal Article
Open access
MVMaria Varnava
Maria Varnava
AMAtsushi Musha
Atsushi Musha
MTMutsumi Tashiro
Mutsumi Tashiro
NKNobuteru Kubo
Nobuteru Kubo
NONaoko Okano
Naoko Okano
TOTatsuya Ohno
Tatsuya Ohno
Background: Carbon ion radiotherapy (CIRT) has been applied in cancer treatment for over 25 years. However, guidelines for dose–volume constraints have not been established yet. The aim of this review is to summarize the dose–volume constraints in CIRT for head‐and‐neck (HN) cancer that were determined through previous clinical studies based on the Japanese models for relative biological effectiveness (RBE).Methods: A literature review was conducted to identify all constraints determined for HN cancer CIRT that are based on the Japanese RBE models.Results: Dose–volume constraints are reported for 17 organs at risk (OARs), including the brainstem, ocular structures, masticatory muscles, and skin. Various treatment planning strategies are also presented for reducing the dose delivered to OARs.Conclusions: The reported constraints will provide assistance during treatment planning to ensure that radiation to OARs is minimized, and thus adverse effects are reduced. Although the constraints are given based on the Japanese RBE models, applying the necessary conversion factors will potentially enable their application by institutions worldwide that use the local effect model for RBE.

12 February 2022 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
MKMotohiro Kawashima
Motohiro Kawashima
MTMutsumi Tashiro
Mutsumi Tashiro
MVMaria Varnava
Maria Varnava
SSShintaro Shiba
Shintaro Shiba
TMToshiaki Matsui
Toshiaki Matsui
TOTatsuya Ohno
Tatsuya Ohno
In carbon-ion radiotherapy for pancreatic cancer, altered dose distributions due to changes in the gastrointestinal gas volume and anatomy during irradiation are an unresolved therapeutic issue. We developed and investigated an adaptive strategy involving beam angle selection to improve dose distributions in pancreatic cancer. In the adaptive strategy, multiple beams were prepared with angles similar to those of the conventional strategy, and the beam that best reproduces the dose distribution of the treatment plan was used. The dose distributions of the adaptive strategy were compared with those of the conventional strategy for five patients. Patients underwent computed tomography (CT) before every irradiation. The adaptive strategy was evaluated using the same irradiation schedule as that of the conventional method and an adjusted method based on anatomical changes per fraction. Dose distributions on the pre-treatment CT and accumulated dose distributions on the treatment planning CT were evaluated using the volume receiving ≥95% of the prescription dose (V95) from the clinical target volume (CTV) between strategies. There were significant differences in the CTV V95 values for the pre-treatment CT between all strategies. The median (range) CTV V95 for the conventional strategy was 92.7% (87.1–96.1%), for the proposed adaptive strategy without adjusted schedules was 96.9% (95.1–97.8%), and for the proposed strategy with adjusted schedules was 97.8% (96.5–99.2%). The adaptive strategy can improve target coverage for the pre-treatment CT and accumulated dose distributions for the treatment planning CT without increasing the dose to critical organs.

22 November 2025 in Technical Innovations & Patient Support in Radiation Oncology
Verified
Journal Article
Open access
MVMaria Varnava
Maria Varnava
MKMotohiro Kawashima
Motohiro Kawashima
AMAkihiko Matsumura
Akihiko Matsumura
YOYoshiaki Oohashi
Yoshiaki Oohashi
MMMakoto Miyazawa
Makoto Miyazawa
TOTatsuya Ohno
Tatsuya Ohno
Upright patient positioning is an emerging approach in radiotherapy that may overcome current limitations in carbon ion radiotherapy (CIRT). This study evaluated upright immobilization techniques for abdominal and head-and-neck (HN) cancers in a CIRT setting. Ten volunteers were positioned on the Chair, a demo upright positioning system (Leo Cancer Care, USA). Three setups were evaluated: no immobilization devices, vacuum bags alone (ESFORM; Engineering System Co., Japan), and vacuum bags with a thermoplastic shell (Shellfitter; Kuraray Trading Co., Japan), called the “shell” setup. Interfractional and intrafractional errors were assessed using skin markers drawn on the abdominal and HN areas. Interfractional shifts per direction and Euclidean distances were calculated by comparing reference and repeated images. Intrafractional shifts per direction and Euclidean distances were calculated from images acquired over a 15-min period. Also, volunteers rated their comfort for each setup on a scale of 1–5. Differences in the interfractional and intrafractional motion, and comfort ratings between the three setups were investigated. Significant differences (p < 0.05) in the interfractional Euclidean distances were observed between the three setups in both anatomical areas, while significant differences were observed in more shifts per direction in the abdominal case. The “shell” setup minimized intrafractional distances. No significant differences were observed in the comfort ratings between the setups. Upright positioning in CIRT appears feasible. Further research is needed to refine immobilization techniques to support clinical implementation of upright positioning in CIRT.

28 March 2025 in Cancer Medicine
Verified
Journal Article
Open access
MVMaria Varnava
Maria Varnava
MTMutsumi Tashiro
Mutsumi Tashiro
MOMasahiko Okamoto
Masahiko Okamoto
KAKen Ando
Ken Ando
NKNobutero Kubo
Nobutero Kubo
TOTatsuya Ohno
Tatsuya Ohno
Background: Applying dose–volume constraints is extremely important in ensuring the safe use of radiotherapy. However, constraints for carbon ion radiotherapy (CIRT) have not been established yet. This review aims to summarize dose–volume constraints for thoracic, abdominal, and pelvic CIRT that have been identified through previous research based on the Japanese models for relative biological effectiveness (RBE).Results: Constraints are reported for the lungs, liver, stomach, gastrointestinal tract, rectum, sigmoid, bladder, nerves, rib, femoral head, sacrum, and skin. The constraints are classified into hard and soft to aid in determining whether priority should be given to the target coverage or organ‐at‐risk (OAR) sparing during treatment planning.Conclusions: Further research is necessary to verify the applicability of the reported constraints and to identify constraints for the OARs that have not been investigated yet.

1 August 2024 in Radiological Physics and Technology
Verified
Journal Article
Open access
PDF file
MKMotohiro Kawashima
Motohiro Kawashima
MVMaria Varnava
Maria Varnava
SOShuichi Ozawa
Shuichi Ozawa
HHHiromitsu Higuchi
Hiromitsu Higuchi
YHYoshihiko Hoshino
Yoshihiko Hoshino
MTMutsumi Tashiro
Mutsumi Tashiro
Electrometers are important devices that are part of the standard dosimetry system. Therefore, we evaluated the variation of electrometer calibration coefficients (kelec) over 1 year in this study. We investigated two types of electrometers: a rate mode and an integrate mode. Each electrometer was connected to a charge generator, a constant charge was applied, and kelec was determined by measuring the current. The current measurements were repeated once a month. For electrometers with multiple ranges, measurements were taken at low and medium ranges. Almost all kelec measurements agreed within 0.2% of the initial measurements. However, the low range of the electrometer with an integrate mode showed seasonal variation, with a variation greater than 0.2%. This study shows that electrometers may exhibit errors that cannot be detected through annual inspections. The importance of quality assurance using a charge generator at one’s own institution was demonstrated.