10 March 2021 in IEEE Access
The integration of energy storage facilities into existing structures will result in increased costs. Therefore, it is of great significance to optimize the configuration of integrated power systems with multienergy flows to reduce the cost of the comprehensive utilization of energy. This study established a wind-solar-battery-fuel cell integrated power supply system to optimize the grid-connected regional power supply. First, the load is given with a known daily energy demand. The optimization goal is to minimize the average annual cost and the loss of power supply probability. The cost model includes the constraints of transportation costs and the benefits of selling hydrogen and oxygen. Then, an improved genetic algorithm is developed to optimize the structure of the wind-solar-battery-fuel cell integrated power supply system. The basic idea of the improved genetic algorithm is to change the coordination mode of the crossover operator and the mutation operator according to the size of the initial population fitness. Finally, according to the calculation results of the improved genetic algorithm, the optimal configuration of the capacity of devices in the system is obtained, verifying the effectiveness of the improved genetic algorithm. The cost calculation result of the genetic algorithm is 18.7% higher than that of the improved genetic algorithm, and it completely converges at approximately 70 steps. The cost calculation result of the particle swarm optimization is 17.1% higher than that of the improved genetic algorithm, and it completely converges at approximately 75 steps. The cost calculation result of the nondominated sorting genetic algorithm is 9.6% higher than that of the improved genetic algorithm, and it completely converges at approximately 58 steps. The system established in this research can fully meet the power demands for a given area and effectively reduce the local curtailment of wind energy and solar energy.
1 October 2026 in Physics of Fluids
Effective inflow velocity reconstruction recovers a reference velocity, representing the external inflow from a near-field velocity field affected by the airfoil. Under attached flow, the difference between local velocity and effective inflow is mainly associated with bound circulation. A circulation distribution on the airfoil profile can, therefore, provide a physically consistent induced velocity correction. Under separated flow, however, near-wall reverse flow and separated vortices distort the local velocity direction, making the airfoil surface inconsistent with the external effective flow. To address this limitation, an effective control body (ECB) model is proposed. It treats the airfoil and separated region as an integrated control body and relocates the circulation support boundary outside the separated region. Two variants define this boundary using a total pressure contour line or stagnation point streamlines. The method is evaluated using unsteady Reynolds-averaged Navier–Stokes flow fields around the Delft University 00-W2-350 airfoil. Under deep stall, the Shen2 model retains a pronounced directional deviation. Both ECB variants recover nearly parallel effective inflow streamlines, bring the inflow angle closer to the prescribed direction, and improve spatial uniformity. During unsteady separation, vortex evolution changes the induced velocity correction with phase, but both variants maintain small inflow angle deviations. Under the investigated two-dimensional separated flow conditions, relocating the circulation support boundary outside the separated region makes the induced velocity correction more consistent with the external flow. The ECB model, therefore, provides a physically motivated approach to effective inflow reconstruction for the examined cases.