Benjamin Böttcher

Benjamin Böttcher

Auto-generated profile, based on publicly available information

Benjamin Böttcher

Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2025 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
BBBenjamin Böttcher
Benjamin Böttcher
FMFelix G. Meinel
Felix G. Meinel
KDKarolin K. Deyerberg
Karolin K. Deyerberg
LWLena‐Maria Watzke
Lena‐Maria Watzke
MMMathias Manzke
Mathias Manzke
AKAnn‐Christin Klemenz
Ann‐Christin Klemenz
Background: Accurate plane positioning is important for high‐quality cardiac MRI images but requires specialized training, limiting accessibility. Purpose: To evaluate an automated plane positioning tool and compare it with manual planning. Study Type: Prospective. Population: Fifty‐seven healthy volunteers (28 males; median age 42 years) and 20 consecutive patients (15 males; median age 61 years) scheduled for clinical cardiac MRI. Field Strength/Sequence: Steady state free precession cine sequence at 1.5 T. Assessment: In volunteers, short‐axis (SAX), 2‐chamber (2CH), 3‐chamber (3CH), and 4‐chamber (4CH) cine images were acquired using both automated and manual prescription. Two blinded radiologists (5 and 6 years of clinical cardiac MRI experience) rated plane quality on a Likert scale (1 = nondiagnostic to 5 = excellent ). Mean plane angle differences between manual and automated prescriptions were calculated. Left and right ventricular end‐systolic volume (ESV), end‐diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF) were compared. In patients, the number of required manual corrections to automated prescriptions was recorded. Statistical Analysis: Wilcoxon matched‐pairs signed rank tests and Bland–Altman analyses, significance level at p ≤ 0.05. Results: Automated plane positioning was successful in all volunteers. Image plane quality did not differ significantly between automated (mean score 4.64) and manual prescription (4.62, p = 0.812). Mean angle differences were 6.7° ± 4.3° (SAX), 10.3° ± 5.8° (2CH), 8.9° ± 5.1° (3CH), and 8.0° ± 4.8° (4CH). Volumetric parameters showed no significant differences between both planning methods with mean biases being −0.5 mL, p = 0.305 (LVEDV), 0.5 mL, p = 0.683 (LVESV), −1.0 mL, p = 0.168 (LVSV) and 0.4%, and p = 0.215 (LVEF). In patients, 8.8% (7/80) of automatically prescribed planes required minor corrections; 91.2% (73/80) were accepted without adjustments. Data Conclusion: Automated plane positioning for cardiac MRI may provide high‐quality images and accurate volumetric assessment comparable to manual planning. Evidence Level: 2. Technical Efficacy: Stage 2.

1 October 2025 in Radiology: Cardiothoracic Imaging
Verified
Journal Article
Closed access
RFRoberto Farì
Roberto Farì
MAMarly van Assen
Marly van Assen
RQRaymundo Quintana
Raymundo Quintana
PDPhilipp von Knebel Doeberitz
Philipp von Knebel Doeberitz
BBBenjamin Böttcher
Benjamin Böttcher
CCCarlo N. De Cecco
Carlo N. De Cecco
A fully automated deep learning algorithm significantly enhanced interreader agreement for coronary artery disease detection and stenosis classification, potentially improving diagnostic consistency at coronary CT angiography.

8 September 2025 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
PDF file
DZDanagul Zhexenova
Danagul Zhexenova
BBBenjamin Böttcher
Benjamin Böttcher
FMFelix G. Meinel
Felix G. Meinel
Atresia of the left main coronary artery (LMCA) refers to a congenital defect in which both the LMCA and its coronary ostium fail to develop, despite the presence of anatomically normal left anterior descending and circumflex branches. This condition is exceedingly uncommon, with fewer than 60 documented instances reported globally over the past 70 years [1]. In cases of LMCA, the existence of Vieussens’ arterial ring – a connection forming a circular anastomosis between the conus branch of the right coronary artery and the left anterior descending artery (LAD)—provides an alternative pathway for perfusion of the otherwise isolated left coronary circulation. This represents a very rare coronary anomaly. Only 7 case reports describing the combination of Vieussens’ ring and left main atresia are documented in the literature [2]. Received: 25 June 2025 Accepted after revision: 21 August 2025 Article published online: 08 September 2025 © 2025. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

21 February 2026 in European Radiology
Verified
Journal Article
Open access
PDF file
KDKarolin K. Deyerberg
Karolin K. Deyerberg
FMFelix G. Meinel
Felix G. Meinel
LWLena-Maria Watzke
Lena-Maria Watzke
AKAnn-Christin Klemenz
Ann-Christin Klemenz
MMMathias Manzke
Mathias Manzke
BBBenjamin Böttcher
Benjamin Böttcher
Objectives: The prescription of cardiac MRI (CMR) image planes is essential for comparable volumetric assessment, but manual planning is time-consuming and error-prone. This prospective single-center study evaluated automated planning and its impact on the reproducibility of volumetric parameters derived from CMR. Materials and methods: Fifty-two healthy volunteers (26 males, median age 44.5 years) were divided into a 1.5 T sub-cohort ( n = 32, both scans at 1.5 T, interval 2–5 weeks) and a 3 T sub-cohort ( n = 20, 1st scan 1.5 T, 2nd scan 3 T, interval 1–2 h). All scans were performed using automated and manual planning with identical protocols, acquiring standard cardiac planes. Subjective quality of plane position was rated blinded by two radiologists. Volumetric analysis was performed fully automatically without corrections on SAX, retrieving right ventricular (RV) and left ventricular (LV) parameters. Wilcoxon matched-pairs signed rank test, intraclass correlation coefficient (ICC), and Bland–Altman analysis were used for statistical assessment. Results: Subjective quality of image planes showed high consistency with good to excellent ratings in both sub-cohorts. Reproducibility of volumetric parameters was good to excellent (all ICC > 0.77) except for LVEF (1.5 T sub-cohort: LVEF manual: 0.323; automated: 0.213; 3 T sub-cohort: LVEF manual: 0.597; automated: 0.742). Overall, reproducibility was better in the 3 T sub-cohort, mainly due to different scan intervals. ICCs were slightly higher compared to manual planning across both sub-cohorts. These trends were also observed in the Bland–Altman analysis. Conclusion: Fully automated plane positioning for CMR provides high-quality image planes, ensuring high reproducibility of cardiac volumetric parameters across both established field strengths. Key Points: Question The prescription of CMR image planes is essential for a comparable volumetric cardiac analysis, but manual planning is time-consuming and error-prone . Findings Automated plane prescription for CMR provides high-quality image planes, ensuring high reliability and reproducibility of cardiac volumetric parameters across both established field strengths . Clinical relevance Automated plane prescription for CMR reliably provides high-quality image planes, ensuring comparable cardiac volumetric parameters. This technology can simplify the acquisition and promises to reduce variability between follow-up scans, as well as to enhance the availability for patients .