13 September 2018 in IEEE Sensors Journal
This paper presents a noncontact radio frequency voltage sensing of a printed trace by using a capacitive-coupled probe. The noncontact voltage sensing is demonstrated by using an open-end coaxial probe, and achieved through the transfer factor from the printed trace to the probe and a reconstruction algorithm. To validate the voltage sensing, known periodic and pulse voltages are injected into the printed trace and compared with the reconstructed waveforms. Our results demonstrate that the voltage sensing method can be used for measurement of a random waveform with period even down to 1 ns and single pulse with rise time down to 2 ns. In consideration of the flexible relocation of the probe, the voltage sensing accuracy caused by spatial errors is also investigated.
23 May 2017 in IEEE Transactions on Instrumentation and Measurement
This paper develops a movable noncontact probing method of a radio frequency current on a printed trace based on the electromagnetic induction. The current measurement method is validated by comparing a series of reconstructed periodic and pulse currents with those as known input signals on a microstrip line. According to our measurement, the transfer impedance from the current under measurement to the probe has a linear frequency range from 10 MHz to 2.2 GHz. The reconstruction measurement can be achieved even for a random periodic noise with a duration of 1 ns and a single pulse with a rise time of 2 ns. Owing to the flexible relocation of the probe, the measurement accuracy due to the errors of spatial displacement and the probe placement angle is investigated in detail. It is shown that the dynamic parameters of reconstructed current, such as fall time and rise time, are insensitive to the spatial errors, and instead the amplitudes of both periodic and pulse currents are highly sensitive, especially to a horizontal displacement.
11 April 2019 in IEEE Transactions on Microwave Theory and Techniques
With the trend of miniature, high-integrated assembly modules are common in modern industry. The measurement of the flowing current and voltage on a trace is basic for diagnosis and monitoring of these modules. The traditional contact detection method is not practical especially in conditions of high power and small space. In this paper, we demonstrate a novel method for collocated and simultaneous measurements of radio frequency current and voltage on a trace in a noncontact and movable manner. The measurements are achieved by using a compact probe with both voltage and current detectors, as well as an algorithm based on the transfer functions quantifying the capacitive and inductive couplings between the detectors and the tested trace. The proposed method is verified and applied for continuous power measurements, collocated and simultaneous measurements of transient voltage and current pulses and the dynamic voltage and current of a switching device.
19 January 2017 in IEEE Transactions on Electromagnetic Compatibility
In this paper, we study the orientation effect of magnetic and electric field-to-line coupling (FtLC) between a microstrip line and a TEM cell by using a square-shaped transmission line pulse as an interference source. With the detections at enough orientations, the electric and magnetic FtLCs can be extracted with high accuracy. It is found that in the TEM cell, the ratio of electric to maximum magnetic FtLC is dominated by the characteristic impedance of the studied microstrip line due to the determined value of width-to-distance. For a certain ratio of electric to maximum magnetic FtLC, there is a singular angle at which the microstrip line gives no response for any electromagnetic interference excitation. Meanwhile, at the supplementary angle, the response of the microstrip line shows no dependence on the termination load.