Haimi Qiu

Haimi Qiu

Auto-generated profile, based on publicly available information

Haimi Qiu

Science and Technology on Reliability Physics and Application of Electronic Component Laboratory, GuangZhou, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WFwenxiao FANG
wenxiao FANG
HQHaimi Qiu
Haimi Qiu
CLChengyang Luo
Chengyang Luo
LWLei Wang
Lei Wang
WSWeiheng Shao
Weiheng Shao
YEYunfei En
Yunfei En
This paper presents a noncontact radio frequency voltage sensing of a printed trace by using a capacitive-coupled probe. The noncontact voltage sensing is demonstrated by using an open-end coaxial probe, and achieved through the transfer factor from the printed trace to the probe and a reconstruction algorithm. To validate the voltage sensing, known periodic and pulse voltages are injected into the printed trace and compared with the reconstructed waveforms. Our results demonstrate that the voltage sensing method can be used for measurement of a random waveform with period even down to 1 ns and single pulse with rise time down to 2 ns. In consideration of the flexible relocation of the probe, the voltage sensing accuracy caused by spatial errors is also investigated.

23 May 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HQHaimi Qiu
Haimi Qiu
WFWenxiao Fang
Wenxiao Fang
YEYunfei En
Yunfei En
YHYun Huang
Yun Huang
YLYuan Liu
Yuan Liu
CSChunlei Shi
Chunlei Shi
This paper develops a movable noncontact probing method of a radio frequency current on a printed trace based on the electromagnetic induction. The current measurement method is validated by comparing a series of reconstructed periodic and pulse currents with those as known input signals on a microstrip line. According to our measurement, the transfer impedance from the current under measurement to the probe has a linear frequency range from 10 MHz to 2.2 GHz. The reconstruction measurement can be achieved even for a random periodic noise with a duration of 1 ns and a single pulse with a rise time of 2 ns. Owing to the flexible relocation of the probe, the measurement accuracy due to the errors of spatial displacement and the probe placement angle is investigated in detail. It is shown that the dynamic parameters of reconstructed current, such as fall time and rise time, are insensitive to the spatial errors, and instead the amplitudes of both periodic and pulse currents are highly sensitive, especially to a horizontal displacement.

11 April 2019 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
CLChengyang Luo
Chengyang Luo
WFwenxiao FANG
wenxiao FANG
YSYang Shen
Yang Shen
HQHaimi Qiu
Haimi Qiu
WSWeiheng Shao
Weiheng Shao
YEYunfei En
Yunfei En
With the trend of miniature, high-integrated assembly modules are common in modern industry. The measurement of the flowing current and voltage on a trace is basic for diagnosis and monitoring of these modules. The traditional contact detection method is not practical especially in conditions of high power and small space. In this paper, we demonstrate a novel method for collocated and simultaneous measurements of radio frequency current and voltage on a trace in a noncontact and movable manner. The measurements are achieved by using a compact probe with both voltage and current detectors, as well as an algorithm based on the transfer functions quantifying the capacitive and inductive couplings between the detectors and the tested trace. The proposed method is verified and applied for continuous power measurements, collocated and simultaneous measurements of transient voltage and current pulses and the dynamic voltage and current of a switching device.

1 July 2018
Verified
Conference Paper
Closed access
HQHaimi Qiu
Haimi Qiu
CLChengyang Luo
Chengyang Luo
WFWenxiao Fang
Wenxiao Fang
LJLijun Jiang
Lijun Jiang
Nonintrusive electromagnetic interference (EMI) detection is a powerful method for EMI diagnosis in high-speed links and multiple signal PCB designs. However, due to the dispersive nature of signal delivery passages and interferences from neighborhood signals, it is very difficult to locate exactly the EMI source of two adjacent traces without contact. In this paper, a noncontact time-domain voltage measurement method is proposed to detect the EMI signals of two adjacent traces on a PCB. A near-field electric probe is employed and a reconstruction algorithm is developed to recover the voltage signals without contact. Through experimental benchmarks, it is demonstrated that the proposed method can successfully recover the common signals, differential signals, and non-correlated signals from the adjacent dual traces. It provides a convenient EMI source measurement method for high-speed and multiple signals PCB diagnosis and optimizations.

19 January 2017 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
WFWenxiao Fang
Wenxiao Fang
YEYunfei En
Yunfei En
YHYun Huang
Yun Huang
YLYuan Liu
Yuan Liu
YCYiqiang Chen
Yiqiang Chen
CSChunlei Shi
Chunlei Shi
In this paper, we study the orientation effect of magnetic and electric field-to-line coupling (FtLC) between a microstrip line and a TEM cell by using a square-shaped transmission line pulse as an interference source. With the detections at enough orientations, the electric and magnetic FtLCs can be extracted with high accuracy. It is found that in the TEM cell, the ratio of electric to maximum magnetic FtLC is dominated by the characteristic impedance of the studied microstrip line due to the determined value of width-to-distance. For a certain ratio of electric to maximum magnetic FtLC, there is a singular angle at which the microstrip line gives no response for any electromagnetic interference excitation. Meanwhile, at the supplementary angle, the response of the microstrip line shows no dependence on the termination load.

1 October 2016
Verified
Conference Paper
Closed access
QLQihai Li
Qihai Li
WFWenxiao Fang
Wenxiao Fang
JXJing Xiao
Jing Xiao
WLWeiming Li
Weiming Li
WCWeiwei Chen
Weiwei Chen
BZBin Zhou
Bin Zhou
With the decrease in the overall size and the rapid increase in the working frequencies of printed circuit boards, the reliability of solder joints, especially the high frequency signal transmission reliability has become the key factor in system reliability. In this paper, changes in RF impedance of solder joints in a temperature cycling environment was studied using time-domain reflectometry measurements. It was found that with the increase in the temperature cycle, the intermetallic compound layer gradually thickened, and even if no macro damage was found, the RF impedance increased. The transmission reliability of the high frequency signal was degraded.