Kusuma Eshwar

Kusuma Eshwar

Auto-generated profile, based on publicly available information

Kusuma Eshwar

Department of Electrical Engineering National Institute of Technology Warangal Warangal India

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SPSagar Gajanan Petkar
Sagar Gajanan Petkar
KEKusuma Eshwar
Kusuma Eshwar
VTVinay Kumar Thippiripati
Vinay Kumar Thippiripati
Model predictive current control (MPCC) is widely used and more popular control method for a permanent magnet synchronous motor (PMSM) drive. It is less complex and simple to understand as compared with other predictive control methods. MPCC involves the evaluation of a simpler cost function for selecting an optimal voltage vector (VV), which is based on the minimization of error between reference and sensed currents. For a two-level inverter with limited number of VV, MPCC gives poor steady-state performance as a single VV is applied over one sampling interval. In this article, for improving the steady-state performance of PMSM, an improved MPCC is proposed. In this proposed MPCC method, an active VV along with a zero VV is applied similar to the duty cycle control (DCC); however, the timings of active VV and zero VV are selected to decrease the q-axis current ripples. The method introduced in this article is based on the calculation of q-axis current slopes to calculate optimal timing for different VVs. The method introduced in this article is compared with conventional MPCC (C-MPCC) and MPCC with DCC. Simulation and experimentation is carried out for comparison and to confirm the effectiveness of introduced MPCC.

22 April 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
EKEshwar Kusuma
Eshwar Kusuma
RMRavi Eswar Kodumur Meesala
Ravi Eswar Kodumur Meesala
TKThippiripati Vinay Kumar
Thippiripati Vinay Kumar
Finite Control Set Model Predictive Control (FCS-MPC) methods are emerging as a powerful control technique for power electronic converters and drives. FCS-MPC methods work on the principle of minimizing a single cost function. The cost function consists of multiple control objectives with different magnitudes and requires weighting factors for optimization. The calculation of the weighting factor is a cumbersome process and it depends on the system parameters and operating conditions. In this paper, a new approach for eliminating the weighting factors in Predictive Torque Control (PTC) method for two-level Voltage Source Inverter (VSI) fed Permanent Magnet Synchronous Motor (PMSM) drive is developed. In the proposed PTC method, the torque and flux objectives are considered as separate cost functions and evaluated with all seven different Voltage Vectors (VVs). The top three VVs corresponding to minimized torque and flux objective cost functions are considered individually. Among these, optimal VV is selected for minimizing both torque and flux ripples. As a result, monotonous flux weighting factors tuning is not required and reduction in switching frequency is also achieved. To validate the proposed methodology, both simulation and experiment results in terms of steady state and dynamic operations of PMSM drive are presented.

5 May 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
KEKusuma Eshwar
Kusuma Eshwar
VTVinay Kumar Thippiripati
Vinay Kumar Thippiripati
The conventional predictive torque control (PTC) of open-end-winding permanent magnet synchronous motor drive with single dc source deals with the problems of complex weighting factor tuning, higher ripples in zero sequence current (ZSC) and increased flux and torque ripples. To mitigate the above drawbacks, an effective weighting-factorless PTC scheme is proposed. Initially, the ZSC objective of cost function is evaluated with three types of zero sequence voltages (ZSV) of the system that are available. The magnitude of ZSV corresponding to the minimized ZSC error is selected. Six or seven candidate voltage vectors are arranged in accordance with optimized ZSV. As the ZSC imposes high impact on torque and current performance, the selected candidate voltage vectors can be used to meet the torque and flux objective. To further eliminate the flux weighting-factor, an improved incremental merit-based scheme is proposed in this article. The weighting-factors tuning is avoided in the proposed PTC method which results in reduced ZSC and improved current performance in addition to the reduced ripples in flux and torque as well as lower computational burden. The effectiveness of the proposed PTC method is experimentally verified and compared with the existing PTC methods.

13 December 2020 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
PLParvathy M L
Parvathy M L
KEKusuma Eshwar
Kusuma Eshwar
VTVinay Kumar Thippiripati
Vinay Kumar Thippiripati
Predictive current control (PCC) is a promising technique for adjustable speed drives due to its intuitive features such as quick response, easy inclusion of non‐linearities and constraints as well as multi‐variable operation. The conventional predictive current control (C‐PCC) employs a cost function to choose the optimum vector, which reduces the error between the reference and the predicted current. Even though the C‐PCC can achieve excellent dynamic performance with a single active voltage, the steady‐state performance is affected with larger torque and flux ripples. When two voltage vectors are applied in a control interval, the steady‐state performance is improved. This paper proposes a modified duty‐based PCC for permanent magnet synchronous motor (PMSM) drives, employing an active and null vector in control interval, where the duration for which the optimal active vector is applied is based upon a simple error based calculation. The proposed duty calculation requires a simple constant and eliminates the need for current slope calculation, which results in parameter insensitive operation. The proposed method is compared with C‐PCC and recently published works based on duty calculation. The simulation and hardware experiments conducted on a PMSM drive confirm the effectiveness of the proposed method with reduced torque and flux ripples.

1 December 2020 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
KEKusuma Eshwar
Kusuma Eshwar
TKThippripati Vinay Kumar
Thippripati Vinay Kumar
The direct torque control (DTC) of permanent magnet synchronous motor (PMSM) drives is a noticeable practice in industrial applications due to its quick dynamic performance. However, due to the presence of hysteresis controllers and inaccurate switching tables especially for the multilevel fed DTC drives are facing higher ripples in torque and flux response. An improved DTC for three‐level open‐end winding PMSM drive is proposed in this article and features reduction of flux and torque ripples. The torque and flux performances of the PMSM are directly controlled by the calculated reference voltage vector in the stationary reference frame. The voltage vector tables are proposed based on the length of the voltage space vectors and the actual voltage vector nearer to the calculated reference voltage vector is selected so that the minimum ripples exist in flux and torque responses. The steady‐state and dynamic conditions of the proposed DTC method are verified in the real‐time experiment and also compared with the conventional DTC as well as the recently developed control methods.

1 October 2020 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
EKEshwar Kusuma
Eshwar Kusuma
VTVinay Kumar Thippiripati
Vinay Kumar Thippiripati
The predictive torque control (PTC) scheme for four-level open-end winding permanent magnet synchronous motor drive (OEW-PMSM) is introduced in this article, owing to its simple and intuitive algorithm. However, the classical PTC-PMSM drive performance mainly depends on the weighting factors (WF) used in cost function (CF) and its selection is a cumbersome process. Hence, a new approach for eliminating these WFs is proposed for four-level PTC-OEW-PMSM drive without dropping its benefits in classical PTC method. The torque and flux objective errors are considered as two individual CFs and evaluated with all available voltage vectors (VVs). Then, the set of VVs corresponding to the ascending orders of CFs magnitudes is considered as separate VVs groups. The common VV present in both these VV groups represents the minimised torque error, flux error and treated as the optimal VV for the next control period. As a result, the monotonous flux WF tuning is no more required. The limited VVs strategy is also proposed for reducing the computational burden of PTC. The proposed four-level PTC method is initially tested in MATLAB/SIMULINK and experimentally verified on PMSM drive.