Hugo Gontijo Machado

Hugo Gontijo Machado

Auto-generated profile, based on publicly available information

Hugo Gontijo Machado

Chemistry Institute

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2026 in Analytical Chemistry
Verified
Journal Article
Open access
HMHugo G. Machado
Hugo G. Machado
EMElliott P. Mueller
Elliott P. Mueller
JRJúlio C. O. Ribeiro
Júlio C. O. Ribeiro
GBGiovanni B. Bevilaqua
Giovanni B. Bevilaqua
GSGabriel dos Santos
Gabriel dos Santos
BVBoniek Gontijo Vaz
Boniek Gontijo Vaz
Stable isotope analysis is a vital tool across chemistry, geology, and environmental science, but conventional Isotope Ratio Mass Spectrometry (IRMS) techniques have limited capabilities for site-specific or multiply substituted ("clumped") isotope analyses, and are particularly limited for analyses of complex mixtures without prior analyte purification. This study addresses this gap by employing a high-resolution Orbitrap mass spectrometer to directly measure the 13C/12C ratio in a model naphthenic acid (1,2,3,4-tetrahydro-2-naphthoic acid, THN) within complex organic matrices. We applied a "zero-enrichment" experimental design to evaluate accuracy and precision by comparing pure standards to the same compound in synthetic samples resembling natural waters. Complementary experiments using low-molecular-weight organic acids and natural rumen fluid were conducted to define the method's limits under controlled and severe ion-suppression conditions. The results demonstrated that matrix effects and ion statistics can substantially degrade both accuracy and precision under certain conditions. At very low analyte concentrations, incomplete ion accumulation led to heightened δ13C variability, a condition analogous to a "blank effect". Paradoxically, adding 1% NH4OH improved the precision of 13C/12C measurements (reducing the relative standard error from ∼0.80‰ to ∼0.63‰ at 0.1 μM THN), despite a reduced signal, by promoting more stable deprotonation and minimizing ion suppression. We also identified that coaccumulated ions, even when baseline-resolved, such as a matrix-derived fragment at m/z 177, degrade precision by perturbing the space-charge balance. Removing this interference fully restored precision, underscoring the need to control coaccumulating ions. Crucially, experiments with small organic acids demonstrated that moderate ion suppression does not lead to isotopic bias, which emerges only when severe suppression reduces analyte ion counts below a critical statistical threshold. Finally, we identified an "isotopic stability plateau"─an optimal signal range where δ13C measurements are most precise and accurate, poised between noise-dominated and space-charge-distorted regimes. This work demonstrates that Orbitrap-MS can perform reliable isotope analysis in complex organic mixtures when instrumental and chemical parameters are carefully optimized, opening new applications in petroleum geochemistry, environmental forensics, and other topics.

27 August 2021 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
NCNayara Coutinho
Nayara Coutinho
HMHugo Gontijo Machado
Hugo Gontijo Machado
VCValter H. Carvalho-Silva
Valter H. Carvalho-Silva
Wender Alves SilvaWender Alves Silva
Wender Alves Silva
New calculations improved by explicit-implicit hybrid treatment ensure that the overall iKIE > 1 does not exclude step R4 as a limiting-step and that the debate about the infallibility of the generalization of step R5 as RCS is reasonable.

1 January 2026 in Journal of the Brazilian Chemical Society
Verified
Journal Article
Closed access
NONaiara R. L. de Oliveira
Naiara R. L. de Oliveira
GSGabriel dos Santos
Gabriel dos Santos
HMHugo G. Machado
Hugo G. Machado
GLGesiane Da Silva Lima
Gesiane Da Silva Lima
Nerilson Marques LimaNerilson Marques Lima
Nerilson Marques Lima
BVBoniek Gontijo Vaz
Boniek Gontijo Vaz
Although Anacardium humile and Anacardium occidentale fruits are widely consumed in Brazil, quantitative data on their bioactive compound content remain scarce. This study aimed to develop and validate a high-performance liquid chromatography mass spectrometry (HPLC‑MS/MS) method for the targeted quantification of 12 metabolites and to assess their antioxidant potential. Twenty-four mature fruit samples were collected from individual trees and purchased from open-air markets in Goiás and the Federal District over three different weeks (during September and October) and were analyzed using a validated method (r > 0.99; relative standard deviation (RSD) < 12.84%; recovery 88-111%). Ascorbic acid was the predominant compound in both species, although notable interspecific differences were observed for catechin, isoquercetin, and gallic acid. Principal component analysis (PCA) confirmed distinct chemical profiles between species. Antioxidant activity varied significantly, with the effective concentration (EC50) values ranging from 65.67 to 381.94 g fruit per g 2,2-diphenyl-1-picrylhydrazyl (DPPH) for A. occidentale and from 85.37 to 227.62 for A. humile. These findings underscore the importance of robust analytical techniques for characterizing the complex phytochemistry of native Brazilian fruits.