Wentao Liu

Wentao Liu

Auto-generated profile, based on publicly available information

Wentao Liu

College of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WLWentao Liu
Wentao Liu
FHFangrong Hu
Fangrong Hu
SLShangjun Lin
Shangjun Lin
LZLizhen Zeng
Lizhen Zeng
QXQingfu Xu
Qingfu Xu
YZYingchang Zou
Yingchang Zou
Squamous cell carcinoma antigen (SCCA) level is an auxiliary indicator for lung cancer diagnosis and predictive monitoring, and its standard reference value is less than 1.5 ng/mL. Therefore, achieving high sensitivity and specific detection of the SCCA is a challenge. In this work, we designed a double split-ring-resonator (SRR) terahertz (THz) metasurface sensor. Simulation results show that the sensitivity of the sensor can reach 103 GHz/RIU (refractive index unit). After the sensor is modified with different concentrations of halloysite-nanotubes (HNTs), the resonant frequency of the sensor exhibits different linear responses to different concentrations of SCCA. The optimum concentration of HNTs to enhance the detection performance of the sensor was obtained as 10 mg/mL. The linear range of SCCA concentration of the HNTs modified sensor was 1 pg/mL-100 ng/mL. On this basis, we modified anti-SCCA on the sensor, and other biomarkers of carcinoembryonic-antigen (CEA), neuron-specific-enolase (NSE), CA125, and CA199 were used as comparisons. The results indicated that the sensor modified with HNTs showed a more remarkable frequency shift for the SCCA, which verified that the sensor had good specificity for the SCCA. Therefore, this sensor can be used for highly sensitive and specific detection of the SCCA.

5 April 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XHXuehe Hou
Xuehe Hou
FHFangrong Hu
Fangrong Hu
LZLonghui Zhang
Longhui Zhang
QXQingfu Xu
Qingfu Xu
LZLizhen Zeng
Lizhen Zeng
ZHZhongliang Hu
Zhongliang Hu
Terahertz (THz) biosensors provide a new avenue for the early diagnosis and treatment of cancers. However, conventional THz biosensors cannot achieve high sensitivity due to limited absorption peaks. In this work, we propose a cancer biomarker ultrasensitive detection method based on THz frequency-comb-like. At first, we design a basic biosensor which has three resonant absorption peaks. Then, we proportionally change the size of basic biosensor and obtain other 4 biosensors with different resonant absorption peaks. Finally, a frequency-comb-like containing 8 uniformly spaced absorption peaks in the range of 0.5 - 1.3 THz is realized by appropriately selecting the absorption peaks of these 5 biosensors. Three cancer biomarkers of carcinoembryonic antigen (CEA), neuron-specific enolase (NSE) and squamous cell carcinoma (SCC) are used as samples of experiment. Under the same concentration, the frequency shifts generated by each peak are accumulated. For samples from 0.1 pg/mL to 50 ng/mL, the cumulative frequency shifts are 122-547 GHz, 168-815 GHz, and 142-505 GHz, respectively. The sensitivity (Sc) of concentration are 64.995 log(ng/ml), 105.005 log(ng/ml), and 62.634 log(ng/ml), respectively. The limit-of-detection (LOD) is 0.1 pg/mL. Compared with other methods using single or few resonant absorption peaks, this method shows higher sensitivity and lower LOD. Therefore, it is valuable for trace molecule detection, biomedical sensing and cancer diagnosis at early stage.