Shangjun Lin

Dr. Shangjun Lin

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2020 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Closed access
SLShangjun Lin
Shangjun Lin
XXXinlong Xu
Xinlong Xu
FHFangrong Hu
Fangrong Hu
ZCZhencheng Chen
Zhencheng Chen
YWYuanli Wang
Yuanli Wang
ZWZhiyou Wang
Zhiyou Wang
An antibody modified terahertz (THz) metamaterial biosensor is proposed to detect the concentration of carcinoembryonic antigen (CEA). The biosensor has four metal split-ring-resonators (SRR) in a unit cell. The finite integration time domain (FITD) method is used to design and optimize the structure. The simulation shows that the biosensor is insensitive to incident angles and the sensitivity reaches to 76.5 GHz/RIU (Refractive Index Unit). The sample is manufactured using a surface micromachining process and characterized by a THz time domain spectroscopy (THz-TDS) system. The experimental results indicate that the resonant frequency of the biosensor decreases with the increase of the concentration of analytes on the surface. After that, the biosensor is modified with anti-CEA and used to detect the concentration of the CEA. Interestingly, the response of the biosensor depends heavily on the concentration of the Anti-CEA modified on the surface of the biosensor. When the concentration of Anti-CEA is 20 ng/ml, the resonant frequency shift shows good linearity to the concentration of CEA and the limit of detection (LOD) reaches to 0.1 ng/ml. This study paves a new way for sensitively detection of biomolecules, cancer biomarkers and immune responses, which is important for early stage diagnosis of cancers.

11 February 2021 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Closed access
DLDongxia Li
Dongxia Li
FHFangrong Hu
Fangrong Hu
HZHaipeng Zhang
Haipeng Zhang
ZCZhencheng Chen
Zhencheng Chen
GHGaoxiang Huang
Gaoxiang Huang
YZYuan Zhou
Yuan Zhou
We propose a simple method for fast and label-free identification of early-stage cervical cancerous tissues using a metamaterial (MM) terahertz (THz) biosensor with two resonant absorption frequencies at 0.286 THz and 0.850 THz, respectively. Because the two resonant absorption frequencies are very sensitive to the ambient change of dielectric properties, the cervical cancerous tissues can be distinguished from the normal tissues by analyzing the resonant frequency shift. The calculated sensitivity of the low resonant frequency and that of the high resonant frequency are 29 and 74 GHz/RIU, respectively. In the experiment, the cervical cancerous tissue samples were taken from different patients, and the cancerous and normal parts were determined by hematoxylin-eosin (HE) stain. Compared with the traditional method of directly detecting cancer tissue without the sensor, this method has the advantages of being simple, label free and fast. In addition, compared with biosensors which have a single resonant absorption frequency, the biosensors with double resonant absorption frequencies have higher accuracy. This method potentially can be applied for the detection and diagnosis of many other cancer tissues.

10 February 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WLWentao Liu
Wentao Liu
FHFangrong Hu
Fangrong Hu
SLShangjun Lin
Shangjun Lin
LZLizhen Zeng
Lizhen Zeng
QXQingfu Xu
Qingfu Xu
YZYingchang Zou
Yingchang Zou
Squamous cell carcinoma antigen (SCCA) level is an auxiliary indicator for lung cancer diagnosis and predictive monitoring, and its standard reference value is less than 1.5 ng/mL. Therefore, achieving high sensitivity and specific detection of the SCCA is a challenge. In this work, we designed a double split-ring-resonator (SRR) terahertz (THz) metasurface sensor. Simulation results show that the sensitivity of the sensor can reach 103 GHz/RIU (refractive index unit). After the sensor is modified with different concentrations of halloysite-nanotubes (HNTs), the resonant frequency of the sensor exhibits different linear responses to different concentrations of SCCA. The optimum concentration of HNTs to enhance the detection performance of the sensor was obtained as 10 mg/mL. The linear range of SCCA concentration of the HNTs modified sensor was 1 pg/mL-100 ng/mL. On this basis, we modified anti-SCCA on the sensor, and other biomarkers of carcinoembryonic-antigen (CEA), neuron-specific-enolase (NSE), CA125, and CA199 were used as comparisons. The results indicated that the sensor modified with HNTs showed a more remarkable frequency shift for the SCCA, which verified that the sensor had good specificity for the SCCA. Therefore, this sensor can be used for highly sensitive and specific detection of the SCCA.

5 April 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XHXuehe Hou
Xuehe Hou
FHFangrong Hu
Fangrong Hu
LZLonghui Zhang
Longhui Zhang
QXQingfu Xu
Qingfu Xu
LZLizhen Zeng
Lizhen Zeng
ZHZhongliang Hu
Zhongliang Hu
Terahertz (THz) biosensors provide a new avenue for the early diagnosis and treatment of cancers. However, conventional THz biosensors cannot achieve high sensitivity due to limited absorption peaks. In this work, we propose a cancer biomarker ultrasensitive detection method based on THz frequency-comb-like. At first, we design a basic biosensor which has three resonant absorption peaks. Then, we proportionally change the size of basic biosensor and obtain other 4 biosensors with different resonant absorption peaks. Finally, a frequency-comb-like containing 8 uniformly spaced absorption peaks in the range of 0.5 - 1.3 THz is realized by appropriately selecting the absorption peaks of these 5 biosensors. Three cancer biomarkers of carcinoembryonic antigen (CEA), neuron-specific enolase (NSE) and squamous cell carcinoma (SCC) are used as samples of experiment. Under the same concentration, the frequency shifts generated by each peak are accumulated. For samples from 0.1 pg/mL to 50 ng/mL, the cumulative frequency shifts are 122-547 GHz, 168-815 GHz, and 142-505 GHz, respectively. The sensitivity (Sc) of concentration are 64.995 log(ng/ml), 105.005 log(ng/ml), and 62.634 log(ng/ml), respectively. The limit-of-detection (LOD) is 0.1 pg/mL. Compared with other methods using single or few resonant absorption peaks, this method shows higher sensitivity and lower LOD. Therefore, it is valuable for trace molecule detection, biomedical sensing and cancer diagnosis at early stage.

14 November 2023 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
JCJie Chen
Jie Chen
FHFangrong Hu
Fangrong Hu
SLShangjun Lin
Shangjun Lin
ZSZihang Song
Zihang Song
ZDZhitao Duan
Zhitao Duan
MJMingzhu Jiang
Mingzhu Jiang

9 April 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JCJie Chen
Jie Chen
FHFangrong Hu
Fangrong Hu
XMXiaoya Ma
Xiaoya Ma
MYMo Yang
Mo Yang
SLShangjun Lin
Shangjun Lin
ASAn Su
An Su
MicroRNA (miRNA) is closely related to various cancers, and the change in its expression level is closely related to the development and death of tumor cells. Here, we design and manufacture a terahertz (THz) metasurface sensor to realize the concentration detection and category identification of the miRNAs related to lung cancer. We established two spectral classification datasets, one contains 9 concentrations of miRNAs, and the other contains 3 categories of lung cancer-related miRNAs. And then, we used a deep neural network (DNN) algorithm to classify these spectral datasets and obtained a LOD (Limit-of-Detection) of 100 aM for miRNAs. Moreover, this method can identify the categories of miRNAs. Compared with the other five machine learning (ML) algorithms, the proposed neural network framework achieves the best classification results. This work provides a new way for the detection and identification of trace nucleic acid and biomarkers of many cancers.