Chan Way Ng

Chan Way Ng

Auto-generated profile, based on publicly available information

Chan Way Ng

Singapore Immunology Network (SIgN), Agency of Science, Technology and Research (A*STAR), Singapore 138673., Singapore, Singapore, Singapore

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FTFarah Tasnim
Farah Tasnim
NSNisha Hari Singh
Nisha Hari Singh
ETElijah Keng Foo Tan
Elijah Keng Foo Tan
JXJiangwa Xing
Jiangwa Xing
HLHuan Li
Huan Li
HYHanry Yu
Hanry Yu
Hepatocyte spheroids are useful models for mimicking liver phenotypes in vitro because of their three-dimensionality. However, the lack of a biomaterial platform which allows the facile manipulation of spheroid cultures on a large scale severely limits their application in automated high-throughput drug safety testing. In addition, there is not yet a robust way of controlling spheroid size, homogeneity and integrity during extended culture. This work addresses these bottlenecks to the automation of hepatocyte spheroid culture by tethering 3D hepatocyte spheroids directly onto surface-modified polystyrene (PS) multi-well plates. However, polystyrene surfaces are inert toward functionalization, and this makes the uniform conjugation of bioactive ligands very challenging. Surface modification of polystyrene well plates is achieved herein using a three-step sequence, resulting in a homogeneous distribution of bioactive RGD and galactose ligands required for spheroid tethering and formation. Importantly, treatment of polystyrene tethered spheroids with vehicle and paradigm hepatotoxicant (chlorpromazine) treatment using an automated liquid handling platform shows low signal deviation, intact 3D spheroidal morphology and Z’ values above 0.5, and hence confirming their amenability to high-throughput automation. Functional analyses performance (i.e. urea and albumin production, cytochrome P450 activity and induction studies) of the polystyrene tethered spheroids reveal significant improvements over hepatocytes cultured as collagen monolayers. This is the first demonstration of automated hepatotoxicant treatment on functional 3D hepatocyte spheroids tethered directly on polystyrene multi-well plates, and will serve as an important advancement in the application of 3D tethered spheroid models to high throughput drug screening.

8 June 2020 in Journal of Cellular and Molecular Medicine
Verified
Journal Article
Open access
PDF file
XYXiao Yu
Xiao Yu
WLWei Lu
Wei Lu
CNChan Way Ng
Chan Way Ng
SXShuoyu Xu
Shuoyu Xu
YWYao Wu
Yao Wu
LSLi Sheng
Li Sheng
Gallbladder carcinoma (GBC) is a vicious and invasive disease. The major challenge in the clinical treatment of GBC is the lack of a suitable prognosis method. Chemokine receptors such as CXCR3, CXCR4 and CXCR7 play vital roles in the process of tumour progression and metastasis. Their expression levels and distribution are proven to be indicative of the progression of GBC, but are hard to be decoded by conventional pathological methods, and therefore, not commonly used in the prognosis of GBC. In this study, we developed a computer‐aided image analysis method, which we used to quantitatively measure the expression levels of CXCR3, CXCR4 and CXCR7 in the nuclei and cytoplasm of glandular and interstitial cells from a cohort of 55 GBC patients. We found that CXCR3, CXCR4 and CXCR7 expressions are associated with the clinicopathological variables of GBC. Cytoplasmic CXCR3, nuclear CXCR7 and cytoplasmic CXCR7 were significant predictive factors of histology invasion, whereas cytoplasmic CXCR4 and nuclear CXCR4 were significantly correlated with T and N stage and were associated with the overall survival and disease‐free survival. These results suggest that the quantification and localisation of CXCR3, CXCR4 and CXCR7 expressions in different cell types should be considered using computer‐aided assessment to improve the accuracy of prognosis in GBC.

2 November 2023
Verified
Conference Paper
Open access
PDF file
XFXinyun Feng
Xinyun Feng
MZMarcia Zhang
Marcia Zhang
WYWilla Yim
Willa Yim
FWFelicia Wee
Felicia Wee
MRMenaka Priyadharsani Rajapakse
Menaka Priyadharsani Rajapakse
MLMai Chan Lau
Mai Chan Lau
Background Advancement in multiplex immunohistochemistry (mIHC) allows for single-cell tumor microenvironment analysis, greatly enhancing our comprehension of cancer immunology.1 However, clinical application of mIHC remains challenging due to technical variations and cost. Hematoxylin and eosin (H&E) staining, a cost-effective method commonly used in clinics, combined with emerging digital pathology,2 offers promising prospects. Increasing evidence suggests that deep learning (DL) can discern molecular variations from histomorphological features in H&E images.3 4 This has sparked research into applying DL to digital H&E images, a concept referred to as H&E 2.0.5 Model training demands accurate cell labels, but traditional manual annotation methods are labor-intensive, time-consuming, and show significant observer variability.3 6 In this study, we investigate and propose the best methods for image registration and nuclear segmentation to create accurate cell labels for training a predictive model particularly for CD3+ T-cell prediction. Our primary aim is to create an automated workflow that enables robust and precise virtual staining on widely used H&E images. Methods The cohort includes 19 triple-negative breast cancer samples in a TMA format. The TMA slide underwent mIHC staining, was subsequently washed, stained with H&E, and imaged. The mIHC staining panel consists of DAPI/CD20/CD3/Ki67/CD163/FOXP3 stains. For each of the samples, the H&E and mIHC stained images were first cropped into individual core areas. Using SIFT from OpenCV (v4.7.0.72), the mIHC images were warped to align with their corresponding H&E images. Nuclear segmentation on H&E images was performed using the pretrained ‘2D_versatile_he’ model from StarDist (v0.8.3) where various probability thresholds were assessed (figure 1). All analysis was performed using Python programming. Results Our findings indicate that the use of SIFT registration significantly enhances the precision of mIHC signal mapping to H&E images, both at the tissue and cellular levels. This is observed through the alignment of the nuclear mask derived from H&E images with the DAPI nuclear signal in mIHC (figure 2). Using the StarDist model on H&E images at a 0.7 probability threshold gave results closest to manual annotation, unlike the over-segmentation seen with DeepCell’s Mesmer algorithm (figure 3). Conclusions We have presented an optimized approach for generating ground truth with minimal user involvement. This approach can be effortlessly scaled to multiple biomarkers and an increased quantity of training images. In future work, we plan to broaden our focus to include other types of tumors and evaluate the impact on the performance of virtual staining predictions. Acknowledgements This work was supported by the Bioinformatics Institute, Singapore Immunology Network, and Insitute of Molecular and Cell Biology, Agency for Science, Technology and Research (A*STAR). References Sahardi VK, Armengol G. Molecular Biomarkers in Cancer. Biomolecules. 2022;12(8):1021. Lee K, Lockhart JH, Xie M, Chaudhary R, Slebos RJC, Flores ER, Chung CH, Tan AC. Deep Learning of Histopathology Images at the Single Cell Level. Front Artif Intell. 2021;4:754641. Liu Y, Li X, Zheng A, Zhu X, Liu S, Hu M, Luo Q, Liao H, Liu M, He Y, Chen Y. Predict Ki-67 Positive Cells in H&E-Stained Images Using Deep Learning Independently From IHC-Stained Images. Front Mol Biosci. 2020;7:183. Coudray N, Ocampo PS, Sakellaropoulos T, Narula N, Snuderl M, Fenyo D, Moreira AL, Razavian N, Tsirigos A. Classification and mutation prediction from non-small cell lung cancer histopathology images using deep learning. Nat Med. 2018;24(10):1559–1567. Comiter C, Vaishnav ED, Ciampricotti M, Li B, Yang Y, Rodig SJ, Turner M, Pfaff KL, Jané-Valbuena J, Slyper M, Waldman J, Vigneau S, Wu J, Blosser TR, Segerstolpe Å, Abravanel D, Wagle N, Zhuang X, Rudin CM, Klughammer J, Rozenblatt-Rosen O, Kobayash-Kirschvink KJ, Shu J, Regev A. Inference of single cell profiles from histology stains with the Single-Cell omics from Histology Analysis Framework (SCHAF). bioRxiv. 2023:2023.03.21.533680. Couture HD. Deep Learning-Based Prediction of Molecular Tumor Biomarkers from H&E: A Practical Review. J Pers Med. 2022;12(12):2022. Overview of study design on optimizing cell labeling for virtual staining of CD3+ cells from H&E images Comparison of pre-SIFT registration (top row) and post-SIFT registration images (bottom row). (A) H&E stained (background layer) and mlHC (front layer, green) image pairs were blended together to show degree of alignment. (B) Inset of blended H&E and mlHC image as shown in (A). (C) StarDist nuclear segmentation mask derived from H&E image overlay on H&E image. (D) StarDist nuclear segmentation mask derived from H&E image overlay on counterpart mlHC DAPI signals. The registered image pair shows higher precision in alignment as compared to the non-registered image pair Assessment of StarDist '2D_versatile_he' model nuclear segmentation performance. (A) StarDist nuclear segmentation algorithm performance at varying probability threshold levels (prob) with a non- maximum suppression threshold of 0.35. StarDist performance on H&E images is compared against Mesmer model from DeepCell library on mlHC images. StarDist gave significantly closer results to the ground truth than Mesmer. Ground truth cell counts are manually determined by a histology expert using Indica Labs HALO® image analysis platform. (B) Comparison of StarDist and Mesmer derived nuclear mask overlays on mlHC DAPI signals from H&E and mlHC-stained images respectively. StarDist displays accurate nuclear segmentation whereas Mesmer yields over-segmentation of the nuclei