Myriam Böhm

Myriam Böhm

Auto-generated profile, based on publicly available information

Myriam Böhm

Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
Christoph LwowskiChristoph Lwowski
Christoph Lwowski
KPKatarzyna Pawlowicz
Katarzyna Pawlowicz
KPKerstin Msc Petermann
Kerstin Msc Petermann
EHEva Msc Hemkeppler
Eva Msc Hemkeppler
LHLisa Msc Hinzelmann
Lisa Msc Hinzelmann
TKThomas Kohnen
Thomas Kohnen
Purpose: To evaluate factors that influence postoperative satisfaction in patients with diffractive extended depth-of-focus (EDoF) and multifocal intraocular lenses (mIOLs). Setting: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. Design: Observational case study. Methods: Patients were evaluated after implantation of a diffractive EDoF (Symfony, AT LARA) or trifocal/quadrifocal (AT LISAtri, Panoptix) 3 months postoperatively. A subjective refraction was performed, uncorrected and corrected visual acuities were tested for distance (UDVA, CDVA), intermediate (at 60 cm and 80 cm, UIVA, DCIVA), and near (at 40 cm, UNVA, DCNVA). A test for contrast sensitivity was performed, and the patients filled 2 different questionnaires on daily activities and optical phenomena. Parameters with a potential correlation to the postoperative overall satisfaction were investigated. Results: 94 patients with a mean age of 66 ± 19 years were included. Patients with a better UDVA and UIVA at 60 cm were more likely to choose the same IOL again. The intensity of subjective optical phenomena and the visual quality at different tasks of daily living influenced overall satisfaction. UIVA at 80 cm, UNVA, and corrected visual acuity demonstrated no significant influence on patient satisfaction. The uncorrected visual acuity at specific distances had a direct impact on the subjective visual quality regarding the task performed at those distances. Conclusions: For patients with diffractive EDoF and tri-/quadrifocal IOLs, the UDVA and UIVA at 60 cm seem to be more important than the UNVA and UIVA at 80 cm. Subjective visual quality and optical phenomena influence patient satisfaction, as well.

1 August 2022 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
MBMyriam Msc Böhm
Myriam Msc Böhm
EHEva Msc Hemkeppler
Eva Msc Hemkeppler
TKThomas Kohnen
Thomas Kohnen
Purpose: To investigate the self-rated quality of vision (SQV) and optical phenomena intensity of 3 diffractive multifocal intraocular lenses (mIOLs). Setting: Department of Ophthalmology, Goethe University Frankfurt, Germany. Design: Prospective comparative case series. Methods: Patients who had bilateral implantation of a diffractive extended depth-of-focus (EDoF), trifocal, or panfocal mIOL were assessed. Outcome parameters were SQV, symptom intensity of optical phenomena under 3 lighting conditions, quality of everyday lifestyle activities, spectacle independence (SI), and contrast sensitivity (CS). Results: The study comprised 108 eyes. The 3 lenses provided good total SQV under all lighting conditions. EDoF patients reported a slightly better total SQV (EDoF: 9.8 ± 6.67, trifocal: 22.2 ± 7.09, panfocal: 19.6 ± 16.25 visual analog scale, P = .041). A similar percentage of patients reported the presence of optical phenomena with no difference between mIOLs (P > .05). EDoF, trifocal, and panfocal patients rated symptom intensity of optical phenomena mild to moderate under all lighting conditions; however, EDoF patients reported a lower symptom intensity of halos (P < .05). Reported quality of everyday lifestyle activities and CS were comparable (P < .05). All panfocal and trifocal patients (100%) achieved complete SI, whereas almost half (44%) of the EDoF patients used reading spectacles. Conclusions: Diffractive EDoF, trifocal, and panfocal mIOLs provided good total SQV with mild to moderate intensity of optical phenomena under all lighting conditions. EDoF patients experienced the same percentage of optical phenomena but reported a weaker symptom intensity of halos and better night-driving ability. EDoF patients would all choose the same IOL, although a significant number of them needed reading spectacles, indicating that SI is not the main factor that determines patient selection of IOLs.

26 February 2021 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
MBMyriam Böhm
Myriam Böhm
PLPia Leon
Pia Leon
AWadam Wylegala
adam Wylegala
STStephan Ong Tone
Stephan Ong Tone
TCTracy Condron
Tracy Condron
UJUla Jurkunas
Ula Jurkunas
Aims To determine the cost-effectiveness of preloaded Descemet membrane endothelial keratoplasty (pDMEK) versus non-preloaded DMEK (n-pDMEK) for the treatment of Fuchs endothelial corneal dystrophy (FECD). Methods From a societal and healthcare perspective, this retrospective cost-effectiveness analysis analysed a cohort of 58 patients with FECD receiving pDMEK (n=38) or n-pDMEK (n=30) from 2016 to 2018 in the Department of Ophthalmology, Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, USA. Exclusion criteria were previous ocular surgeries (other than uncomplicated cataract surgery), including other keratoplasty procedures, ocular pathological conditions as glaucoma, amblyopia, laser treatments, or any retinal or corneal disease. The main outcome parameters were the incremental cost-utility ratio (ICUR) and net monetary benefit (NMB). Results pDMEK was less costly compared with n-pDMEK (healthcare: $13 886 vs $15 329; societal: $20 805 vs $22 262), with a slighter greater utility (QALY 0.6682 vs QALY 0.6640) over a time horizon of 15 years. pDMEK offered a slightly higher clinical effectiveness (+0.0042 QALY/patient) at a lower cost (healthcare: –$1444 per patient; societal: –$1457 per patient) in improving visual acuity in this cohort of patients with FECD. pDMEK achieved a favourable ICUR and NMB compared with n-pDMEK. Based on sensitivity analyses performed, the economic model was robust. Conclusions From the societal and healthcare perspective, pDMEK was less costly and generated comparable utility values relative to n-pDMEK. Therefore, pDMEK appears to be cost-effective and cost saving with respect to n-pDMEK. Further long-term follow-up data are needed to confirm these findings.

1 June 2022 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
MBMyriam Msc Böhm
Myriam Msc Böhm
MMMichael Müller
Michael Müller
JPJulia Paul
Julia Paul
EHEva Msc Hemkeppler
Eva Msc Hemkeppler
TKThomas Kohnen
Thomas Kohnen
Purpose: To compare agreement of anterior segment parameter measurements using an intraoperative optical coherence tomography (iOCT) of a femtosecond laser (LenSx) during interface docking to the eye with preoperative Scheimpflug tomography (Pentacam AXL) and swept-source optical coherence tomography (SS-OCT) (IOLMaster 700). Setting: Department of Ophthalmology, Goethe University, Frankfurt, Germany. Design: Retrospective study. Methods: Anterior segment measurements were performed in mydriasis prior to surgery using Scheimpflug tomography and SS-OCT. Postoperatively, iOCT images were analyzed using a modification of the FIJI image-processing program. Outcome measures included external anterior chamber depth (ACD), central corneal thickness (CCT), and central lens thickness (LT). Results: 95 eyes of 66 patients who underwent planned OCT guided femtosecond laser-assisted lens surgery were included. The ACD measured with the iOCT was −0.011 ± 0.126 mm smaller (P = .389) than that with the SS-OCT and −0.059 ± 0.185 mm than with the Scheimpflug tomography (P = .003). The SS-OCT measured a −0.047 ± 0.146 mm smaller ACD than the Scheimpflug tomography (P = .002). The measurements of CCT using the iOCT and the Scheimpflug tomography (−0.705 ± 20.837 μm, P = .742) and the LT measurements using SS-OCT and iOCT (−0.050 ± 0.089 mm, P < .001) showed no clinically relevant difference. Only the ACD between the iOCT and the Scheimpflug tomography showed a clinically relevant difference. Conclusions: The comparison of the anterior segment parameters of iOCT with SS-OCT showed no clinically relevant differences regarding the ACD and the LT. However, Scheimpflug tomography vs iOCT measured a small clinically relevant difference for ACD. The iOCT showed no clinically relevant differences in anterior segment parameters compared with the SS-OCT. A small clinically relevant difference for ACD was found in comparison with that of a Scheimpflug device.

1 September 2025 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Open access
TKThomas Kohnen
Thomas Kohnen
KKKlemens Paul Kaiser
Klemens Paul Kaiser
MBMarvin Biller
Marvin Biller
PDPetra Davidova
Petra Davidova
AKAnnika Klinkenbusch
Annika Klinkenbusch
MBMyriam Böhm
Myriam Böhm
Purpose: To evaluate the 1-year efficacy and safety of the 1-piece multifocal intraocular lens (IOL) Clareon PanOptix CNWT. Setting: Department of Ophthalmology, Goethe-University, Frankfurt, Germany. Design: A prospective, single-center, single-arm, interventional study. Methods: Patients with cataract underwent bilateral implantation of a Clareon PanOptix multifocal IOL after phacoemulsification. Examinations included manifest refraction, uncorrected distance visual acuity (UDVA), and corrected distance visual acuity at 4 m, 80 cm, 60 cm, 40 cm, and 30 cm, defocus test, contrast sensitivity under photopic and mesopic conditions and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence. The primary outcome was visual acuity after 12 months postoperatively. Results: The binocular UDVA was −0.04 ± 0.08 logMAR and at intermediate (80 cm and 60 cm) and near (40 cm and 30 cm) −0.03 ± 0.05 logMAR, −0.04 ± 0.11 logMAR and 0.05 ± 0.11, 0.19 ± 0.12 logMAR, respectively. The binocular distance-corrected defocus curve showed a peak at 0.0 diopter (D) and −2.0 D with −0.07 logMAR and −0.02 logMAR, and between +0.50 D and −3.00 D within 0.10 logMAR. At 12 months, there was no evidence of glistenings in any eye. 24 (89%) participants would choose the IOL again, and 23 of 27 (85%) would recommend the IOL to others. Conclusions: The trifocal Clareon PanOptix IOL provides patients with good visual performance and spectacle independence at all distances without evidence of IOL glistenings.

1 February 2025 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
KKKlemens Paul Kaiser
Klemens Paul Kaiser
MBMarvin Lucas Biller
Marvin Lucas Biller
TJTyll Jandewerth
Tyll Jandewerth
PDPetra Davidova
Petra Davidova
EHEva Msc Hemkeppler
Eva Msc Hemkeppler
TKThomas Kohnen
Thomas Kohnen
Purpose: To investigate the in vivo corneal biomechanical response to FS-LASIK combined with accelerated corneal crosslinking (LASIK Xtra) compared with conventional FS-LASIK (convLASIK) in highly myopic eyes. Setting: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. Design: Prospective, randomized fellow eye-controlled clinical trial. Methods: Patients who received treatment with LASIK Xtra (30mW/cm2, 90 seconds with continuous UV-A) in 1 eye and convLASIK in the other eye were enrolled. Both eyes were subjected preoperatively and 12 months postoperatively to a Corvis ST examination. The stiffness parameter at first applanation (SP-A1), integrated inverse radius (IIR), deformation amplitude (DA), deformation amplitude 2 mm away from apex, and the apical deformation (DARatio2mm) were evaluated. Results: The study included 38 high myopic eyes (−7.34 ± 1.02 diopters) of 19 patients. The results of the corneal biomechanical measurement showed a significant reduction in overall corneal stiffness with a significant decrease in postoperative SP-A1 and increase in IIR, DA, and DARatio2mm (P < .001). In a direct comparison, there was no evidence of an increase in corneal stiffness in the LASIK Xtra group compared with the convLASIK group 12 months postoperatively. No statistically significant difference was detected in any of the 4 biomechanical parameters (P > .05). Conclusions: The corneal biomechanical response to convLASIK and LASIK Xtra did not vary significantly. With a similar corneal thickness loss, there was no significant difference in the 4 biomechanical metrics between the convLASIK and LASIK Xtra groups. Thus, LASIK Xtra appeared not to have a protective corneal stiffening effect compared with convLASIK 12 months postoperatively.