Klemens Paul Kaiser

Dr. Klemens Paul Kaiser

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2024 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
Christoph LwowskiChristoph Lwowski
Christoph Lwowski
YWYaroslava Wenner
Yaroslava Wenner
KKKlemens Paul Kaiser
Klemens Paul Kaiser
ESEva Sapok
Eva Sapok
TKThomas Kohnen
Thomas Kohnen
Purpose: To evaluate the ESCRS online calculator for intraocular lens (IOL) calculation in children undergoing lens extraction and primary IOL implantation. Setting: Department of Ophthalmology, Goethe-University Frankfurt, Frankfurt am Main, Germany. Design: Retrospective, consecutive case series. Methods: Eyes that received phacoemulsification and IOL implantation (Acrysof SN60AT) due to congenital or juvenile cataract were included. We compared the mean prediction error (MPE), mean and median absolute prediction error (MAE, MedAE) of formulas provided by the recently introduced online calculator provided by the ESCRS with the SRK/T formula, as well as the number of eyes within ±0.5 diopters (D), ±1.0 D, ±2.0 D of target refraction. Postoperative spherical equivalent was measured by retinoscopy 4 to 12 weeks postoperatively. Results: 60 eyes from 47 patients with a mean age of 6.5 ± 3.2 years met the inclusion criteria. Mean axial length was 22.27 ± 1.19 mm. Mean preoperative spherical equivalent (SE) was −0.25 ± 3.78 D, and mean postoperative SE was 0.69 ± 1.53 D. The MedAE was lowest in the SRK/T formula (0.56 D, ± 1.03) performed significantly better (P = .037) than Hoffer QST and Kane, followed by BUII (0.64 D, ± 0.92), Pearl DGS (0.65 D, ± 0.94), EVO (0.69 D, ± 0.94), Hoffer QST (0.75 D, ± 0.99), and Kane (0.78 D, ± 0.99). All of those were significantly above zero (P < .001). 41 eyes received an intraoperative optic capture (68%). When excluding eyes that did not receive intraoperative optic capture (n = 19; 32%), the MedAE was shown to be lower. Conclusions: Using modern IOL calculation formulas provided by the ESCRS calculator provides good refractive predictability and compares for most of the formulas with the results with SRK/T. In addition, the formulas seem to anticipate the postoperative refraction better for eyes that receive a posterior optic capture.

21 July 2024 in Clinical & Experimental Ophthalmology
Verified
Journal Article
Open access
KKKlemens Paul Kaiser
Klemens Paul Kaiser
TJTyll Jandewerth
Tyll Jandewerth
JBJulian Bucur
Julian Bucur
TKThomas Kohnen
Thomas Kohnen
Christoph LwowskiChristoph Lwowski
Christoph Lwowski
Background: To assess changes in ocular biometry of the phakic eye after pars‐plana‐vitrectomy (PPV) and silicone oil (SO) endotamponade in eyes with a retinal detachment.Methods: This retrospective, consecutive case series included 72 eyes of 72 patients who underwent PPV with 5000‐centistokes SO endotamponade between July 2018 and June 2023. Pseudophakic eyes and eyes with a combined phacovitrectomy were excluded. Primary endpoints were keratometry values, anterior chamber depth (ACD), lens thickness (LT), horizontal corneal diameter (HCD), and axial length (AL) measured by swept‐source optical coherence tomography‐based biometry (IOLMaster 700) preoperatively and six weeks postoperatively. A recently described formula was used to adjust the AL (aAL) in eyes with SO endotamponade and a theoretical intraocular lens (IOL) calculation was performed.Results: The mean age was 62.1 ± 8.3 years (range: 37–85). After PPV with SO fill, there was an increase in Kmean (0.19 ± 0.51D), while ACD (0.05 ± 0.13 mm), LT (0.03 ± 0.14 mm), and HCD (0.02 ± 0.24 mm) decreased. Preoperatively, the mean AL was 25.22 ± 1.78 mm, while postoperatively the AL was overestimated by 0.12 ± 0.42 mm on average (p = 0.04). By adjusting the AL, the mean difference could be reduced to −0.002 ± 0.41 mm. The aAL resulted in a difference in the refractive outcome in eyes with an AL > 25 mm of 0.34 ± 0.10D in the IOL calculation.Conclusions: While changes in biometry after PPV with SO endotamponade in the anterior segment are clinically less relevant, a considerable overestimation of AL with IOLMaster 700 was found. We recommend the use of a recently introduced formula for adjusting AL in eyes with SO, allowing overestimation to be minimised considerably.

1 September 2025 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Open access
TKThomas Kohnen
Thomas Kohnen
KKKlemens Paul Kaiser
Klemens Paul Kaiser
MBMarvin Biller
Marvin Biller
PDPetra Davidova
Petra Davidova
AKAnnika Klinkenbusch
Annika Klinkenbusch
MBMyriam Böhm
Myriam Böhm
Purpose: To evaluate the 1-year efficacy and safety of the 1-piece multifocal intraocular lens (IOL) Clareon PanOptix CNWT. Setting: Department of Ophthalmology, Goethe-University, Frankfurt, Germany. Design: A prospective, single-center, single-arm, interventional study. Methods: Patients with cataract underwent bilateral implantation of a Clareon PanOptix multifocal IOL after phacoemulsification. Examinations included manifest refraction, uncorrected distance visual acuity (UDVA), and corrected distance visual acuity at 4 m, 80 cm, 60 cm, 40 cm, and 30 cm, defocus test, contrast sensitivity under photopic and mesopic conditions and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence. The primary outcome was visual acuity after 12 months postoperatively. Results: The binocular UDVA was −0.04 ± 0.08 logMAR and at intermediate (80 cm and 60 cm) and near (40 cm and 30 cm) −0.03 ± 0.05 logMAR, −0.04 ± 0.11 logMAR and 0.05 ± 0.11, 0.19 ± 0.12 logMAR, respectively. The binocular distance-corrected defocus curve showed a peak at 0.0 diopter (D) and −2.0 D with −0.07 logMAR and −0.02 logMAR, and between +0.50 D and −3.00 D within 0.10 logMAR. At 12 months, there was no evidence of glistenings in any eye. 24 (89%) participants would choose the IOL again, and 23 of 27 (85%) would recommend the IOL to others. Conclusions: The trifocal Clareon PanOptix IOL provides patients with good visual performance and spectacle independence at all distances without evidence of IOL glistenings.

16 October 2023 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
Christoph LwowskiChristoph Lwowski
Christoph Lwowski
KKKlemens Paul Kaiser
Klemens Paul Kaiser
JBJulian Bucur
Julian Bucur
PSPhilipp Schicho
Philipp Schicho
TKThomas Kohnen
Thomas Kohnen
Purpose Evaluate whether the axial length of the fellow eye can be used to calculate the intraocular lens (IOL) in eyes with retinal detachment. Design Retrospective, consecutive case series. Methods Our study was conducted at the Goethe University and included patients who underwent silicone oil (SO) removal combined with phacoemulsification and IOL implantation. Preoperative examinations included biometry (IOLMaster 700, Carl Zeiss). We measured axial length (AL) of operated eye (OE) or fellow eye (FE) and compared mean prediction error and mean and median absolute prediction error (MedAE) using four formulas and AL of the OE (Barrett Universal II (BUII)-OE). Additionally, we compared the number of eyes within ±0.50, ±1.00 and ±2.00 dioptre (D) from target refraction. Results In total, 77 eyes of 77 patients met our inclusion criteria. MedAE was lowest for the BUII-OE (0.42 D) compared with Kane-FE (1.08 D), BUII-FE (1.02 D) and Radial Basis Function 3.0 (RBF3.0)-FE (1.03 D). This was highly significant (p<0.001). The same accounts for the number of eyes within ±0.50 D of the target refraction with the BUII-OE (44 eyes, 57%) outperforming the RBF3.0-FE (20 eyes, 25.9%), Kane-FE and BUII-FE formula (21 eyes, 27.2%) each. Conclusion Our results show a statistically and clinically highly relevant reduction of IOL power predictability when using the AL of the FE for IOL calculation. Using the AL of the SO filled eye after initial vitrectomy results in significantly better postoperative refractive results. A two-step procedure using the AL of the OE after reattachment of the retina is highly recommended.

9 August 2021 in Egyptian Journal of Neurosurgery
Verified
Journal Article
Open access
PDF file
KKKlemens Paul Kaiser
Klemens Paul Kaiser
MNM. Nayil
M. Nayil
ARA. Ramzan
A. Ramzan
SSS. Sarbjit
S. Sarbjit
WAW. Abrar
W. Abrar
HAHairul Azhar Abdul-Rashid
Hairul Azhar Abdul-Rashid
Indocyanine green (ICG) is a near-infrared (NIR) fluorescent dye. After intravenous injection, it reaches the vessels of the brain within 30 s. A real-time visualization of the cerebral vasculature is possible. The infarction rate and the postoperative rebleed rate in the pre-ICG era group were higher than in the ICG era. Intraoperative ICGVA is a safe and effective method to confirm the exclusion of the clipped aneurysm from the circulation. It also helps to assess the patency of the surrounding vessels.

1 February 2025 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
KKKlemens Paul Kaiser
Klemens Paul Kaiser
MBMarvin Lucas Biller
Marvin Lucas Biller
TJTyll Jandewerth
Tyll Jandewerth
PDPetra Davidova
Petra Davidova
EHEva Msc Hemkeppler
Eva Msc Hemkeppler
TKThomas Kohnen
Thomas Kohnen
Purpose: To investigate the in vivo corneal biomechanical response to FS-LASIK combined with accelerated corneal crosslinking (LASIK Xtra) compared with conventional FS-LASIK (convLASIK) in highly myopic eyes. Setting: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. Design: Prospective, randomized fellow eye-controlled clinical trial. Methods: Patients who received treatment with LASIK Xtra (30mW/cm2, 90 seconds with continuous UV-A) in 1 eye and convLASIK in the other eye were enrolled. Both eyes were subjected preoperatively and 12 months postoperatively to a Corvis ST examination. The stiffness parameter at first applanation (SP-A1), integrated inverse radius (IIR), deformation amplitude (DA), deformation amplitude 2 mm away from apex, and the apical deformation (DARatio2mm) were evaluated. Results: The study included 38 high myopic eyes (−7.34 ± 1.02 diopters) of 19 patients. The results of the corneal biomechanical measurement showed a significant reduction in overall corneal stiffness with a significant decrease in postoperative SP-A1 and increase in IIR, DA, and DARatio2mm (P < .001). In a direct comparison, there was no evidence of an increase in corneal stiffness in the LASIK Xtra group compared with the convLASIK group 12 months postoperatively. No statistically significant difference was detected in any of the 4 biomechanical parameters (P > .05). Conclusions: The corneal biomechanical response to convLASIK and LASIK Xtra did not vary significantly. With a similar corneal thickness loss, there was no significant difference in the 4 biomechanical metrics between the convLASIK and LASIK Xtra groups. Thus, LASIK Xtra appeared not to have a protective corneal stiffening effect compared with convLASIK 12 months postoperatively.