Optimum procedures for epidural steroid injection are summarized, with descriptions of the anatomy of the epidural space, indications for epidural steroid injection, preprocedural preparations, inj... Advances in imaging and the development of injection techniques have enabled spinal intervention to become an important tool in managing chronic spinal pain. Epidural steroid injection (ESI) is one...
This study aimed to assess the feasibility and performance of an artificial intelligence (AI) model for detecting three common wrist fractures: distal radius, ulnar styloid process, and scaphoid. The AI model was trained with a dataset of 4432 images containing both fractured and non-fractured wrist images. In total, 593 subjects were included in the clinical test. Two human experts independently diagnosed and labeled the fracture sites using bounding boxes to build the ground truth. Two novice radiologists also performed the same task, both with and without model assistance. The sensitivity, specificity, accuracy, and area under the curve (AUC) were calculated for each wrist location. The AUC for detecting distal radius, ulnar styloid, and scaphoid fractures per wrist were 0.903 (95% C.I. 0.887–0.918), 0.925 (95% C.I. 0.911–0.939), and 0.808 (95% C.I. 0.748–0.967), respectively. When assisted by the AI model, the scaphoid fracture AUC of the two novice radiologists significantly increased from 0.75 (95% C.I. 0.66–0.83) to 0.85 (95% C.I. 0.77–0.93) and from 0.71 (95% C.I. 0.62–0.80) to 0.80 (95% C.I. 0.71–0.88), respectively. Overall, the developed AI model was found to be reliable for detecting wrist fractures, particularly for scaphoid fractures, which are commonly missed.
To compare the image quality of CT obtained using a deep learning-based image reconstruction (DLIR) engine with images with adaptive statistical iterative reconstruction-V (AV). Using a phantom, the noise power spectrum (NPS) and task-based transfer function (TTF) were measured in images with different reconstructions (filtered back projection [FBP], AV30, 50, 100, DLIR-L, M, H) at multiple doses. One hundred and twenty abdominal CTs with 30% dose reduction were processed using AV30, AV50, DLIR-L, M, H. Objective and subjective analyses were performed. The NPS peak of DLIR was lower than that of AV30 or AV50. Compared with AV30, the NPS average spatial frequencies were higher with DLIR-L or DLIR-M. For lower contrast objects, TTF in images with DLIR were higher than those with AV. The standard deviation in DLIR-H and DLIR-M was significantly lower than AV30 and AV50. The overall image quality was the best for DLIR-M (p < 0.001). DLIR showed improved image quality and decreased noise under a decreased radiation dose.
: Radiology plays a key role in the diagnosis of arthritis. We herein suggest an algorithmic approach to diagnosing arthritis. First, the number of joint involvements is reviewed. Monoarticular arthritis includes septic arthritis, pigmented villonodular synovitis, and synovial chondromatosis. Second, polyarticular arthritis can be categorized by its characteristics: erosive, productive, and mixed. Erosive disease includes rheumatoid arthritis, hemophilia, and amyloidosis, while productive disease includes osteoarthritis and hemochromatosis. Third, mixed diseases are subcategorized by symmetricity. Ankylosing spondylitis and inflammatory bowel disease related arthritis affect joints symmetrically, while psoriatic arthritis, reactive arthritis, and crystalline arthropathy are asymmetric. Adjacent soft tissue density, periostitis, and bone density are ancillary findings that can be used as additional differential diagnostic clues. The final step in identifying the type of arthritis is to check whether the location is a site frequently affected by one particular disease over another. This systematic approach would be helpful for radiologists in diagnosing arthritis.