David Scott Mueller

David Scott Mueller

Auto-generated profile, based on publicly available information

David Scott Mueller

AbbVie (United States), North Chicago, IL, United States

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
CCColum Crowe
Colum Crowe
MSMarco Sica
Marco Sica
LKLorna Kenny
Lorna Kenny
BOBrendan O'Flynn
Brendan O'Flynn
DMDavid Scott Mueller
David Scott Mueller
STSalvatore Tedesco
Salvatore Tedesco
Motor symptoms such as tremor and bradykinesia can develop concurrently in Parkinson’s disease; thus, the ideal home monitoring system should be capable of tracking symptoms continuously despite background noise from daily activities. The goal of this study is to demonstrate the feasibility of detecting symptom episodes in a free-living scenario, providing a higher level of interpretability to aid AI-powered decision-making. Machine learning models trained on wearable sensor data from scripted activities performed by participants in the lab and clinician ratings of the video recordings of these tasks identified tremor, bradykinesia, and dyskinesia in the supervised lab environment with a balanced accuracy of 83%, 75%, and 81%, respectively, when compared to the clinician ratings. The performance of the same models when evaluated on data from subjects performing unscripted activities unsupervised in their own homes achieved a balanced accuracy of 63%, 63%, and 67%, respectively, in comparison to self-assessment patient diaries, further highlighting their limitations. The ankle-worn sensor was found to be advantageous for the detection of dyskinesias but did not show an added benefit for tremor and bradykinesia detection here.

19 November 2025 in JMIR Formative Research
Verified
Journal Article
Open access
LKLorna Kenny
Lorna Kenny
MSMarco Sica
Marco Sica
CCColum Crowe
Colum Crowe
LOLauren O'MAhony
Lauren O'MAhony
BOBrendan O'Flynn
Brendan O'Flynn
STSuzanne Timmons
Suzanne Timmons
Background: Wearable devices have the potential to provide reliable and objective assessment and monitoring of Parkinson disease (PD). During design, there is often a focus on technical performance, accuracy, and reliability, with less emphasis on the user experience. Objective: This study explored the user experience of a novel prototype wearable device (wrist- and ankle-worn) to record limb movements (accelerations and angular velocities), and physiological data (eg, photoplethysmography and heart rate information for estimation of blood pressure). Methods: This qualitative study used internet-based semistructured interviews with people with PD, following wearing prototype devices for 24 hours at home. Interviews were audio-recorded and transcripts analyzed using a hybrid deductive and inductive approach. Results: Six people with PD, 3 male and 3 female, aged 52-83 years, with mild-to-moderate PD (Hoehn and Yahr scale score ≤3; median MDS-UPDRS [Movement Disorder Society - Unified Parkinson’s Disease Rating Scale] score of 72/199) and cognition within normal limits (6-item Cognitive Impairment Test median score 0), with an average disease duration of 8 years took part in the study. Participants were overall positive toward the device, finding it generally comfortable, light in weight and noninvasive. Five out of 6 participants reported minor problems related to strap adjustability and challenges specific to PD. The prototype was comfortable, but this was a lesser priority than robustness, the device not hindering their usual clothing choices (device size or outward projection, or both), and adjustability for fit, including the need to switch to an elasticated strap. In particular, a discreet design was important, as some individuals may feel self-conscious about wearing visible condition-specific products, due to stigma. The ankle-worn device was perceived as unfamiliar and nondiscreet, with some participants likening it to a prisoner tracking system and dressing specifically to conceal it. The wrist-worn device was considered more user-friendly, especially if designed discreetly and resembling more familiar devices. Five of the 6 participants believed their health care teams should have access to the data, particularly relating to their symptoms, fluctuations, and medication. Three also wished to access these data for self-management. One participant was hesitant regarding the potential benefits of technology to support PD management, preferring to use feedback data personally and relying on their health care team’s usual assessment to guide decisions. Across the group, desirable device technical features included symptom prediction, reminder prompts, and support for medication management. Despite concerns about stigma, most participants were willing to wear PD-specific devices, believing that they could aid better symptom management. Conclusions: In summary, wearable devices must be discreet, robust, comfortable, and easily applied to promote adherence regardless of technical specifications.

18 March 2025 in JMIR Preprints
Verified
Preprint
Open access
LKLorna Kenny
Lorna Kenny
MSMarco Sica
Marco Sica
CCColum Crowe
Colum Crowe
LOLauren O'MAhony
Lauren O'MAhony
BOBrendan O'Flynn
Brendan O'Flynn
STSuzanne Timmons
Suzanne Timmons
BACKGROUND Wearable devices have the potential to provide reliable and objective assessment and monitoring of Parkinson disease (PD). During design, there is often a focus on technical performance, accuracy, and reliability, with less emphasis on the user experience. OBJECTIVE This study explored the user experience of a novel prototype wearable device (wrist- and ankle-worn) to record limb movements (accelerations and angular velocities), and physiological data (eg, photoplethysmography and heart rate information for estimation of blood pressure). METHODS This qualitative study used internet-based semistructured interviews with people with PD, following wearing prototype devices for 24 hours at home. Interviews were audio-recorded and transcripts analyzed using a hybrid deductive and inductive approach. RESULTS Six people with PD, 3 male and 3 female, aged 52-83 years, with mild-to-moderate PD (Hoehn and Yahr scale score ≤3; median MDS-UPDRS [Movement Disorder Society - Unified Parkinson’s Disease Rating Scale] score of 72/199) and cognition within normal limits (6-item Cognitive Impairment Test median score 0), with an average disease duration of 8 years took part in the study. Participants were overall positive toward the device, finding it generally comfortable, light in weight and noninvasive. Five out of 6 participants reported minor problems related to strap adjustability and challenges specific to PD. The prototype was comfortable, but this was a lesser priority than robustness, the device not hindering their usual clothing choices (device size or outward projection, or both), and adjustability for fit, including the need to switch to an elasticated strap. In particular, a discreet design was important, as some individuals may feel self-conscious about wearing visible condition-specific products, due to stigma. The ankle-worn device was perceived as unfamiliar and nondiscreet, with some participants likening it to a prisoner tracking system and dressing specifically to conceal it. The wrist-worn device was considered more user-friendly, especially if designed discreetly and resembling more familiar devices. Five of the 6 participants believed their health care teams should have access to the data, particularly relating to their symptoms, fluctuations, and medication. Three also wished to access these data for self-management. One participant was hesitant regarding the potential benefits of technology to support PD management, preferring to use feedback data personally and relying on their health care team’s usual assessment to guide decisions. Across the group, desirable device technical features included symptom prediction, reminder prompts, and support for medication management. Despite concerns about stigma, most participants were willing to wear PD-specific devices, believing that they could aid better symptom management. CONCLUSIONS In summary, wearable devices must be discreet, robust, comfortable, and easily applied to promote adherence regardless of technical specifications.